• Title/Summary/Keyword: Output Monitoring

Search Result 597, Processing Time 0.021 seconds

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.

A Study on Bypass Characteristics for Photovoltaic Module (태양광모듈 바이패스 특성에 관한 연구)

  • Chae, Myoung-Suk;Suh, Hun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.79-80
    • /
    • 2014
  • In this paper, to make sure that the photovoltaic solar cell module of the system can be normal for output in each solar cell module, input and output unit is installed in the bypass device, and then through the voltage and current monitoring to determine abnormality of the solar cell module, in the case of abnormal occurring, the bypass device can be pass to the next solar module of the serial structure.

  • PDF

Resolved Motion Control of the Robot Manipulator using Neural Network (신경회로망을 이용한 로보트 매니츌레이터의 Resolved Motion제어기의 설계)

  • 송문철;조현찬;이홍기;전홍태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.5
    • /
    • pp.519-526
    • /
    • 1990
  • In this paper we propose the resolved motion controller using a neural network for a robot manipulator. Neural identifier designed by a neural network is trained by using a feedback force as an error signal. The identifier approximates the output of a unknown nonlinear system by monitoring both the input and the output of this system. If the neural network is sufficiently trained well, it does not require either strict modelling of the manipulator or precise parameter estimation. The effectiveness of the proposed controller is demonstrated by computer simulation using a two-link planar robot.

  • PDF

Performance Evaluation according to Optical Power of Laser Diode of Optical Fiber Displacement Sensor for Monitoring High Speed Spindle. (고속주축 모니터링용 광파이버 변위센서의 레이저 다이오드 출력에 따른 성능평가)

  • 박찬규;신우철;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.376-380
    • /
    • 2004
  • This paper is to develop an optical ruer displacement sensor for monitoring high speed spindle. Proper magnitude of optical power as well as amplification of output signal are necessary to improve sensitivity of the sensor. In this paper, to meet the need of improvement of the sensor resolution, we choose proper optical power and amplification level through speculating on optical power of a laser diode.

  • PDF

Real-time FECG monitoring system using digital signal processing (디지탈 신호처리에 의한 실시간 태아 심전도 감시 시스템)

  • 김남현;김원기;윤대희;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.580-585
    • /
    • 1990
  • This paper presents a real time FECG signal monitoring system in which an adaptive multichannel noise canceller is implemented using a Texas Instruments TMS32020 digital signal processor. Abdominal ECG signal is applied as the desired output and 3 chest ECG signals as the reference input signals of the adaptive multichannel noise canceller whose coefficients are updated using the LMS algorithms.

  • PDF

Development of living body information and behavior monitoring system for nursing person

  • Ichiki, Ai;Sakamoto, Hidetoshi;Ohbuchi, Yoshifumi
    • Journal of Engineering Education Research
    • /
    • v.17 no.4
    • /
    • pp.15-20
    • /
    • 2014
  • The non-contact easy detecting system of nursing person's body vital information and their behaviors monitoring system are developed, which consist of "Kinect" sensor and thermography camera. The "Kinect" sensor can catch the body contour and the body moving behavior, and output their imaging data realtime. The thermography camera can detect respiration state and body temperature, etc. In this study, the practicability of this system was verified.

Evaluation of the Output Dose of a Linear Accelerator Photon Beams by Using the Ionization Chamber TM31010 Series through TG-51 Protocol to Postal Monitoring Output of RPC for 5 Years (TM31010 계열의 공동이온전리함과 TG-51을 이용한 선형가속기광자선의 5년간 출력선량 평가)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • This study is to keep the accuracy and stability of the output dose evaluations for linear accelerator photon beams by using the air ionization chambers (TM31010, 0.125 cc, PTW) through the Task Group 51 protocol. The absorbed dose to water calibration factor $N_{dw}{^{Co-60}}$ was delivered from the air kerma calibration factor $N_k$ which was provided from manufacture through SSDL calibration for determination of output factor. The ionization chamber of TM31010 series was reviewed the calibration factor and other parameters for reduce the uncertainty within ${\pm}2%$ discrepancy and we found the supplied $N_{dw}{^{Co-60}}$ which was derived from Nk has shown a -2.8% uncertainty compare to that of PSDL. The authors provided the program to perform the output dosimetry with TG-51 protocol as it is composed same screen of TG-51 worksheets. The evaluated dose by determination of output factor delivered to postal TLD block for comparison the output dose to that of MDACC (RPC) in postal monitoring program. The results have shown the $1.001{\pm}0.013$ for 6 MV and $0.997{\pm}0.012$ discrepancy for 15 MV X rays for 5 years followed. This study shows the evaluated outputs for linear accelerate photon beams are very close to that of international output monitor with small discrepancy of ${\pm}1.3%$ with high reliability and showing the gradually stability after 2010.

A Study on Processor Monitoring for Integration Test of Flight Control Computer equipped with A Modern Processor (최신 프로세서 탑재 비행제어 컴퓨터의 통합시험을 위한 프로세서 모니터링 연구)

  • Lee, Cheol;Kim, Jae-Cheol;Cho, In-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.10
    • /
    • pp.1081-1087
    • /
    • 2008
  • This paper describes limitations and solutions of the existing processor-monitoring concept for a military supersonics aircraft Flight Control Computer (FLCC) equipped with modern architecture processor to perform the system integration test. Safecritical FLCC integration test, which requires automatic test for thousands of test cases and real-time input/output test condition generation, depends on the processor-monitoring device called Processor Interface (PI). The PI, which relies upon on the FLCC processor's external address and data-bus data, has some limitations due to multi-fetching capability of the modern sophisticated military processors, like C6000's VLIW (Very-Long Instruction Word) architecture and PowerPC's Superscalar architecture. Several techniques for limitations were developed and proper monitoring approach was presented for modem processor-adopted FLCC system integration test.

A Study on the Wear Detection of Drill State for Prediction Monitoring System (예측감시 시스템에 의한 드릴의 마멸검출에 관한 연구)

  • 신형곤;김태영
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.103-111
    • /
    • 2002
  • Out of all metal-cutting process, the hole-making process is the most widely used. It is estimated to be more than 30% of the total metal-cutting process. It is therefore desirable to monitor and detect drill wear during the hole-drilling process. One important aspect in controlling the drilling process is monitoring drill wear status. There are two systems, Basic system and Online system, to detect the drill wear. Basic system comprised of spindle rotational speed, feed rates, thrust torque and flank wear measured by tool microscope. Outline system comprised of spindle rotational speed feed rates, AE signal, flank wear area measured by computer vision, On-line monitoring system does not need to stop the process to inspect drill wear. Backpropagation neural networks (BPNs) were used for on-line detection of drill wear. The output was the drill wear state which was either usable or failure. This paper deals with an on-line drill wear monitoring system to fit the detection of the abnormal tool state.

Building wireless network in patient monitoring system by SMS protocol based CDMA (환자감시장치간 무선 네트워크 구축을 위한 CDMA 기반 SMS 프로토콜)

  • 정승호;김영길;김동학
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.534-537
    • /
    • 2003
  • The patient monitoring system is equipment that is taking and displaying vital signals from patient. among the rest, the patient monitoring system for doctor guarantee mobility. So, doctor can use information of patients at any time, in any place. The proposed patient monitoring system to get more mobility, efficiency, and have good function. SMS Protocol in CDMA have profits which is low power, low cost, and low microwave output.

  • PDF