• Title/Summary/Keyword: Output Measurement

Search Result 1,462, Processing Time 0.026 seconds

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

Linear Quadratic Regulation and Tracking using Output Feedback with Direct Feedthrough

  • Kang, Seungeun;Cha, Jihyoung;Ko, Sangho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.593-603
    • /
    • 2016
  • This paper presents the development of linear quadratic regulation and output tracking algorithms using output feedback when both the measurement and performance output equations contain direct feedthrough terms. Although all physical systems can be modeled without direct feedthrough, there are still many situations where system models with direct feedthrough are important. For this situation, we modify previous work on the same topic for systems without direct feedthrough. It is shown that for the regulation problem, the optimal output feedback gain for a direct feedthrough case can be directly obtained, via a transformation, from the approach used for systems without direct feedthrough. However, for the tracking problem, a new set of coupled matrix equations for determining the optimal output feedback gain is derived from the necessary conditions for minimizing the cost function. The effectiveness of the developed algorithms is demonstrated using numerical examples.

Fiber Bragg grating sensor using a Mach-Zehnder interferometer and EDFA for EDFA for simultaneous measurement of strain and temperature. (마하젠더 간섭계와 EDFA를 이용한 온도와 스트레인을 동시에 측정하는 광섬유 브래그 격자 센서)

  • 최민호;김부균;정재훈;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.371-375
    • /
    • 2001
  • We have implemented a sensor head which consists of erbium doped fiber pumped by 1480 nm LD and single fiber Bragg grating for simultaneous measurement of strain and temperature. The measurement precision and speed are improved by using Mach-Zehnder interferometer instead of optical spectrum analyzer (OSA) as a demodulator. The measurement precision of temperature measured by the amplitude variation of output signal is 0.05$^{\circ}C$ and that of strain measured by the phase variation of output signal is 0.1$\mu$strain. The measurement precision of temperature and strain are improved nearly 140 times and 700 times, respectively, compared to those using an OSA with wavelength resolution of 0.97 nm as d demodulator.

  • PDF

A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement (입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구)

  • Cho, Sang-Jun;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

Evaluation of Torsional Vibration Isolation Damper in Automotive Transmissions Based on In-situ Torque Measurement (토크 측정을 이용한 차량 변속기용 비틀림 진동 절연 댐퍼 평가)

  • Kim, Gi-Woo;Jang, Jae-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.4
    • /
    • pp.377-382
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

Development of a V-Band Millimeter-Wave Source Module

  • Kwon, Jae-Yong;Lee, Dong-Joon;Bakti, Aditia Nur;Angin, Windi Kurnia Perangin
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.225-228
    • /
    • 2016
  • KRISS-V, a V-band millimeter-wave source module for a primary RF power standard and calibration system developed by the Korea Research Institute of Standards and Science is here presented. The output power of KRISS-V is several times higher than that of commercial amplifier/multiplier chains and is highly stable (the standard deviations of output power are less than 0.01% in the worst case). The spectral purity of KRISS-V is high enough to consider it a single-tone signal generator. We also added programmable attenuation capability to KRISS-V for remote power control. Moreover, the in-house source module is cost-effective and adaptable to various measurement schemes. The structure of the model as well as detailed component information are introduced so that it can be reproduced.

A PORTABLE TORQUE AND POWER MEASUREMENT SYSTEM FOR SMALL FARM EQUIPMENT BASED ON AN INSTRUMENTED PULLEY

  • Pasikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.298-306
    • /
    • 1993
  • A portable torque and power measurement system for small farm equipment based on instrumented pulley was developed. The prototype pulley was machined from mild steel, with spokes serving as strain beams. Strain gages mounted to the spokes sense the bending strain due to the torque and convert this into millivolt output. Calibration results showed the torque-millivolt relationship was linear, while hysterisis and error were less than 1% fs. For power measurements, an additional tachmeter with dcvoltage output is necessary. With the tachometer , error in power measurement was +-1.03W or 0.2% fs. Field tests showed that for ease of installation, no machine alteration needed and safety, this system had advantage over other methods for small farm equipment.

  • PDF

An alternating motion technique using linear variable differential transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • Choi, Ju-Ho;Kim, Yoon-Gyeom;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1380-1383
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

A Study on the Stabilization Scheme of Optical Source for Precision Measurement (정밀측정을 위한 안정된 광원에 관한 연구)

  • 김지대;서호성;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.265-271
    • /
    • 2003
  • This study is for the stable optical source in order to get the precision measurement, which contributes to help the laser frequency and the output to be settled. The laser optical frequency is changed by the length of resonance cavity. The length variation of the laser resonance amplitude is affected by the thermal expansion of that system. So, we try not only to adjust the temperature of the laser tube using the heater for fine length of resonance cavity, but also to maintain the fixed temperature of the resonance cavity for outputting the safe laser optical frequency. Therefore, we must take materials with the thermal expansion of the supporting system, which is closer to it of the laser resonance cavity. Using the materials, we can promote to stabilize the temperature of it. In advance, we also plan to get the settlement of the laser frequency and the output in the long km, optimizing and stabilizing the system.

  • PDF