• Title/Summary/Keyword: Output LC filter

Search Result 98, Processing Time 0.027 seconds

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Nonlinear Control of Output Voltages of PWM Inverters for Stand-Alone Wind Power Generation (독립형 풍력발전용 PWM 인버터의 출력전압의 비선형 제어)

  • Jang, Jeong-Ik;Koo, Seoung-Young;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.131-138
    • /
    • 2007
  • In this paper, a novel nonlinear control method of the CVCF(constant voltage and constant frequency) output voltage for the three-phase PWM inverter with LC output filters is proposed. A nonlinear modeling including the output LC filters is linearized by feedback linearization theory, the controllers of which can be designed based on a linear control theory. It is applied to the DC/AC power conversion of the PWM inverter for stand-alone wind power generation system. It has been verified by the experimental results that the proposed control scheme gives high dynamic responses at load variation as well as a zero steady-state error.

LC filter design for reducing output voltage harmonics (출력 전압 고조파 저감을 위한 LC 필터설계)

  • Han, Dong Yeob;Kim, Sungmin
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.453-454
    • /
    • 2020
  • 본 논문은 PWM에 의한 전압 고조파를 분석하여 LC 필터를 설계하는 방안을 제안한다. 전압형 인버터는 PWM 방식을 이용하여 출력전압을 합성하며, PWM에 의한 전압 고조파는 직류단 전압, Modulation index, Deadtime 등에 의해서 결정된다. 출력 전압 고조파와 PWM 전압고조파와의 관계를 풀어 LC 필터를 설계한다. 제안된 방법으로 설계된 LC 필터는 시뮬레이션을 통해 설계의 타당성을 확인하였다.

  • PDF

Surge Protective Device Combined with Varistor and LC Filter on AC Power Circuits (바리스터와 LC필터를 조합한 교류 전원용 서지보호장치)

  • 이복희;이경옥;안창환;이승칠;박정웅
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.109-116
    • /
    • 1997
  • This paper describes the surge protective device combined with varistor and LC low pass filter on AC power circuits. Up to now varistors alone have been used as a surge protective device on AC power circuits, but it gives negative effects on the equipments to be protected due to the steep rise and high remnant voltage. Therefore in this work, for the purpose of improving the cutoff performance of surge protective device on AC power circuits, the hybrid-type surge protective device with varistor and LC filter was designed and prepared. And the experiments for operational characteristics and clamping performance of the surge protective device were carried out with an 1.2/50[$\mu$s] impulse generator. As a result, the proposed surge protective device with the combination of varistors and LC filter can limit the surge voltage to lower value and reduce the value of dV /dt to very small values. Also the attenuation of high-frequency voltages across the output port is effectively provided by LC filter. Therefore this result may be all the more helpful avoiding both damage and upset of electronic systems.

  • PDF

The Study of Ripple Reduction of the PFC CCM Flyback Converter without Electrolytic Capacitor for LED Lightings using LC Resonant Filter (LC 공진 필터를 이용한 전해 커패시터 없는 LED 구동용 PFC CCM 플라이백 컨버터의 출력 전류 리플 저감에 관한 연구)

  • KIm, Choon-Tack;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.601-610
    • /
    • 2016
  • The light-emitting diode (LED) has been used in a variety of industrial fields and for general 0lighting purposes on account of its high efficiency, low power consumption and long lifespan. The LED is driven by direct current; therefore, an AC/DC converter is typically required for its use. An electrolytic capacitor is generally used for stabilizing DC voltage during use of the AC/DC converter. However, this capacitor has a short lifespan, which makes it a limiting factor in LED lighting. Furthermore, LED lighting requires a dimmable control to enable energy savings and fulfil a growing consumer demand. In this paper, the dimmable single-stage power factor correction (PFC) continuous conduction mode (CCM) flyback converter that employs no electrolytic capacitor is presented. The LC resonant filter is alternatively applied to reduce the 120[Hz] ripple on the output. And the optimum value of the LC resonant filter parameters considering both efficient and performance is analysed. Simulation and experimental results verify the satisfactory operation of the converter.

Characteristics of Utility Transformer on Household Single-Phase ESS-PCS According to LC Filter Location (주택용 단상 ESS-PCS의 LC 필터위치에 따른 상용변압기의 특성)

  • Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.101-105
    • /
    • 2018
  • Shortage of electric power occurs frequently along with increased electric power demand. ESS is a precaution to solve this issue. Household ESS has a capacity of approximately 3 kW/7 kWh. Household ESS batteries are typically designed with nominal voltages between 40 and 50 V. To connect household ESS with a 220 V AC system, low battery voltages in power conditioning system (PCS) should be boosted. To boost low battery voltage and match it with AC grid voltage, the use of a transformer for a commercial frequency can be considered. To attenuate switching harmonics of the household single-phase ESS-PCS, LC filter can be installed in two positions: on the primary side or on the secondary side of a transformer. A method has been used generally in single-phase inverters for the ESS-PCS. In another method, however, the output efficiency of the ESS-PCS may be decreased. Parasitic components of the transformer can affect voltage losses, when the square wave with the switching frequency in the ESS-PCS is passed through the transformer windings. In this work, the characteristics of the transformer according to the position of an LC filter are investigated for household single-phase ESS-PCS.

Characteristic analysis of input and output filter for UPS system (무정전전원장치용 입출력 필터 특성 분석)

  • Lee Dong Ju;Jung Seok Un;Lee Kyung Seok
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.803-806
    • /
    • 2004
  • In this paper, configuration of prototype 300kVA UPS system with unity input power factor is briefly described and a various types of rectifier for UPS application are discussed. Input LCL filter for PWM rectifier and output LC filter for PWM inverter are designed as a prototype and their principal characteristics are discussed.

  • PDF

Output Filter Design of Voltage Source Inverter for CVCF System (CVCF용 VSI의 출력필터 설계)

  • 김재식;최재호
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.287-290
    • /
    • 1999
  • This paper describes an optimal design method of VSI output filter for CVCF system. The cost function is used for design, and all parameters are described in p.u(per unit) so that can be adapted to the change of CVCF rating. The capacitor current feedback scheme is proposed to control the damping ratio of the filter plant to meet the system more stable. This means that the LC resonance can be suppressed well in transient condition and can use the same control gains under the change of system capacity. The validity of the proposed method is well verified with the theoretical analysis and simulation results.

  • PDF

A Sturdy on WLAN RFIC VCO based on InGaP/GaAs HBT (InGaP/GaAs HBT를 이용한 WLAN 용 Low Noise RFIC VCO)

  • Myoung, Seong-Sik;Park, Jae-Woo;Cheon, Sang-Hoon;Yook, Jong-Gwan
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.155-159
    • /
    • 2003
  • This paper presents fully integrated 5 GHz band low phase noise LC tank VCO. The implemented VCO is tuned by integrated PN diode and tuning rage is $5.01{\sim}5.30$ GHz under $0{\sim}3 V$ control voltage. For good phase noise performance, LC filtering technique, common in Si CMOS process, is used, and to prevent degradation of phase noise performance by collector shot-noise and to reduce power dissipation the HBT is biased at low collector current density bias point. The measured phase noise is -87.8 dBc/Hz at 100 kHz offset frequency and -111.4 dBc/Hz at 1 MHz offset frequency which is good performance. Moreover phase noise is improved by roughly 5 dEc by LC filter. It is the first experimental result in InGaP/GaAs HBT process. The figure of merit of the fabricated VCO with LC filter is -172.1 dBc/Hz. It is the best result among 5 GHz InGaP HBT VCOs. Moreover this work shows lower DC power consumption, higher output power and more fixed output power compared with previous 4, 5 GHz band InGaP HBT VCOs.

  • PDF

Properties of Filter type Magnetoimpedance Sensor (필터타입으로 구성한 자기임피던스센서의 특성)

  • SaGong, Geon;Kim, Young-Hak;Shin, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.337-340
    • /
    • 2004
  • To develop the highly sensitive Magneto-Impedance sensor, the amorphous ribbon was micro-processed to meander type sensor pattern and the filter circuit was constructed with this pattern. Its external magnetic field dependence of impedance and the output properties of the filter circuit were investigated. The impedance of the pattern had a peak value at the magnetic field of 10 Oe and its changing ratio was about 280%. The impedance change per unit magnetic field was about 36%, in which the output with high sensitivity and linearity could be obtained. The output sensitivity was about 7%/Oe at bias field of 6 Oe..

  • PDF