• Title/Summary/Keyword: Outdoor structure

Search Result 234, Processing Time 0.022 seconds

10 years of outdoor Exposure based on the results of the Carbonation and Salinity Inhibition Finishing Materials Review (옥외 폭로 10년의 결과에 기초한 마감 재료의 중성화 및 염분 억제 효과 검토)

  • Park, Jae-Hong;Hasegawa, Takuya;Osamu, Senbu;Oh, Sang-Gyun;Park, Dong-Choen
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.45-47
    • /
    • 2011
  • Finishing materials used during the construction of reinforced concrete structures aid in providing resistance to carbonation and help ensure the durability of a structure. However, detailed examinations of this phenomena using data gained from long-term outdoor exposure are not only lacking, but also are not taken into account as factors affected by the local environment. In this research, the velocity coefficient in terms of carbonation is compared as a difference according to the local region and the averaged annual temperature, and the carbonation-preventive effects of finishing materials are analyzed. As an outcome of this study, the results of long-term carbonation can be evaluated from carbonation resistance R induced by an acceleration carbonation test.

  • PDF

Analysis on the Surface Luminance of Outdoor Lighting by Viewing Distance (경관조명의 시점거리별 표면휘도 특성분식)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.18-25
    • /
    • 2006
  • Existing outdoor lighting evaluation methods for the city beautification at night, the measurements are limited by one point to analyze the photometric data. However, this methods could not represent the diversity of photometric result from the distance. This study aims to propose the new outdoor lighting evaluation method of structure surface luminance in accordance with the measuring distance. For the purpose, the field measurement and simulation of an illuminated structure were conducted by CS-100, Digital Photometry Instrument ProMetric 1400, and the Lightscape v 3.2 from the distance of 100[m], 300[m], 500[m]. The result shows that evaluation of the surface luminance by the distance should be measured from about 100[m] of an illuminated object for getting the familiar result from computer simulation.

Injection molding analysis for LED outdoor lighting top cover of one heat sink body type structure (방열체 일체형 구조의 LED 아웃도어 등기구 상부커버에 관한 사출성형해석)

  • Lee, Kwan-Young
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.42-48
    • /
    • 2020
  • This study is on the injection molding analysis for the LED outdoor lighting top cover of one heat sink body type structure. Thermoplastic and thermosetting resins were applied to compare the thermal properties during the injection molding process. The thermoplastic resin is used in this study due to special characteristics that it is light, good strength and dose long not transmute quality even if pass long time. The thermosetting resin is applied to this study due to good in strength, lightweight and excellent etc, thermal conductivity. This study presented a preliminary analysis of fill time, weld line, air trap etc. for the injection molding process of LED lamp cover and body through simulation using Moldflow. As a result of the study, it was selected HTM-102 material because the thermosetting resin has excellent strength and heat conductivity.

Basic Study on Quality Assurance of Concrete Structure by using Odor Sensor (후각센서 사용에 의한 콘크리트 구조물의 품질평가에 관한 기초적 연구)

  • Shirokado, Yoshitsugu;Kagaya, Makoto;Lee, Sang-Hun
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.42-42
    • /
    • 2010
  • In order to assure the quality of concrete structure in construction process, the odor strength measured by using odor sensor was used to evaluate curing effect. Then, the compressive strength and odor strength in ordinary concrete N were shown in water curing(=standard curing), indoor and outdoor atmospheric curing condition. The difference between odor strength in the standard curing and that in each curing condition was defined as the difference in the odor strength. And the difference in odor strength in slag powder concrete BP cured in water curing(=standard curing) for different period before exposing in outdoor atmosphere in winter season were evaluated at the age of 14 days. A necessity to prolong the moisture curing for the slag powder concrete BP compared with the ordinary concrete N to obtain a required curing effect was shown by measuring the odor strength and long term compressive strength.

  • PDF

Evaluation of Self-cleaning Property by Measuring Brightness of Tio2 Coating Ceramic Tile under Outdoor Exposure Test (옥외폭로시험 Tio2 코팅 세라믹 타일의 명도측정에 의한 방오특성 평가)

  • Shin, Dae-Yong;Kim, Kyung-Nam
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.345-349
    • /
    • 2008
  • $TiO_2$ coating ceramic tile for self-cleaning purpose was prepared by the precipitant dropping method using $TiCl_4$ as a precursor. $TiO_2$ film was formed on the ceramic tile by spray-coating technique and heat-treated at $500^{\circ}C$ for 1 h. The size and crystalline structure of $TiO_2$ particles were 15.3 nm and anatase phase. The outdoor exposure tests were conducted and the effects of outdoor exposure test conditions, such as exhaust concentration of contamination materials (test places), the UV light intensity (irradiation direction) and coating amounts of $TiO_2$ on the self-cleaning properties were investigated by the brightness measurements. As a results, self-cleaning property of $TiO_2$ coating tile was affected by the coating amount of $TiO_2$ however, not affected by the UV light intensity included in sun's ray (irradiation direction). $TiO_2$ coating ceramic tile can be utilized for exterior finishing materials because of self-cleaning property of $TiO_2$ coating tile.

Seasonal Contribution of Indoor generated- and Outdoor Originating PM2.5 to Indoor Concentration Depending on Airtightness of Apartment Units (공동주택의 기밀성능에 따른 실외 유입 및 실내 발생 PM2.5의 계절별 실내농도 기여도 분석)

  • Park, Bo Ram;Choi, Dong Hee;Kang, Dong Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.155-163
    • /
    • 2020
  • Indoor airborne particles are consisted of outdoor- and indoor-generated particles, which can be characterized by their compositions, generation features and toxicity. The identification of source contribution of indoor and outdoor origin to indoor particles is important to understand PM2.5 transport in a building as well as its impact on occupant health. The objective of this study is to investigate seasonal source contribution to indoor PM2.5 concentration depending on airtightness of apartment units. To evaluate the source contribution, particle transport including penetration, generation, exfiltration in an apartment housing unit was simulated by using CONTAM with particle and airflow simulation parameters obtained from field measurements. The result showed that the outdoor source contribution to indoor air was relatively dominant in the leaky housing unit during spring (77.2%) and winter (73.9%), and the indoor source was dominant in the airtight housing unit during summer (60.3%) and fall (60.7%). These results indicate the seasonal health risk of indoor PM2.5 can be varied according to airtightness of apartment units.

A Study on the Design of a Wearable Solar Energy Harvesting Device Based on Outdoor Activities (아웃도어 활동기반 웨어러블 광에너지 하베스팅 장치 디자인에 관한 연구)

  • Lee, Eunyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1224-1239
    • /
    • 2020
  • This study develops a wearable solar energy harvesting device that absorbs solar energy to generate and store power which can be used during outdoor activities by users even after dark. For this study, a prototype hat for outdoor activities at night was developed after the design of a solar energy harvesting generation, storage, and delivery system was designed that could store energy to light up LEDs. First, the main control board of the system was designed to integrate the charging function, the darkness detection circuit, the battery voltage sensing circuit, and the LED driving circuit in order to reduce bulkiness and minimize the connection structure. It was designed to increase convenience. Second, the system was designed as a wearable fashion product that connected each part with fiber bands and manufacturing it so as to be detachable from the hat. Third, charging and LED operation tests show that the battery is fully charged after 5 hours even in winter when the illuminance value is low. In addition, the LED operation experiment verified the effectiveness of a buffered system that could operate the LEDs for about 3 hours at night.

The Relationship between the User's Perception of Socio-cultural Attributes and the Spatial Structures of Dwelling Spaces - a Comparative Study between Korean and German Housings - (거주자의 대 사회적 개념과 주거공간의 영역별 구성체계와의 관계 - 한국과 독일의 주거형태학적 비교관찰을 통하여 -)

  • 전남일
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.31-42
    • /
    • 2002
  • This comparative study between Korean and German housings aims at understanding different structural systems in the indoor and outdoor spaces, depending upon the user′s perception of the socio-cultural attributes. The analysis starts with four alternative contrary assumptions, that appear in morphological forms of dwelling; 1) linear distribution vs. areal distribution of residential districts, 2) mirror system vs. comb system in the layout of plot plans 3) organization of front vs. back outdoor spaces and 4) opening vs. closing in the indoor spaces. A clear difference is found between Korean and German samples in view of public and private relationships between indoor and outdoor spaces as well as the intermediate space. In the korean housing there always exists a symbolic and psychological territory of a certain sphere. On the other hand, outdoor space passes through various phases only to form a certain hierarchy even in a private space and, thereby, sets a boundary between private and public areas. In the case of Germany, the building itself draws a clear line between private and public outdoor spaces, and therefore the outdoor space has a "front" and "back". Thus, Germany′s private space may face a genuine public space and street, which is rare in the Korean housing. Although the layout of indoor space in the korean housing tends to be open, such an openness may be outstanding in living and dining spaces, kitchen and various accesses to rooms. In the case of Germany, such indoor spaces are usually closed to each other. Thus corridors act to separate these spaces. Such differences are analysed to be due to the different perceptions of interpersonal and socio-cultural attributes as intra-family and inter-neighbor relationships or communications.

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.