• Title/Summary/Keyword: Outdoor monitoring

Search Result 183, Processing Time 0.023 seconds

Paint booth volatile organic compounds emissions in an urban auto-repair center

  • Cho, Minkyu;Kim, Ki-Hyun;Szulejko, Jan E.;Dutta, Tanushree;Jo, Sang-Hee;Lee, Min-Hee;Lee, Sang-hun
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.329-337
    • /
    • 2017
  • A major concern regarding most auto-repair shops in residential areas is the emission of odorous volatile organic compounds (VOCs) into the local atmosphere, especially during painting operations. VOCs contribute to poor local air quality and are responsible for the perceived odor and discomfort experienced by local residents. Sixteen major VOCs (6 aromatic hydrocarbons and 10 aliphatic carbonyl compounds) were selected as potential target compounds. The site was an auto-repair shop located in a central region of Seoul, South Korea, where the air quality of the site has been a subject of residents' complaints. The sampling points were as follows: 1) in the painting booth with new (NB) or old (OB) removal system, (2) in the exhaust duct after new (ND) or old (OD) odor removal filter, and (3) 2 m below the discharge vent (4 m above the ground) (outdoor air, OA). Each sample was coded: (1) before painting (BP), (2) during painting (DP), and (3) after painting (AP). The toluene level in the duct with the new removal filter during painting (ND-DP) was 1.5 ppm (v/v), while it was 3.8 ppm (v/v) in the right duct with an old removal filter during painting (OD-DP). Accordingly, the effect of filter replacement was reflected by differences in VOC levels. Therefore, accurate monitoring of odorous VOCs is an important step to reduce odor nuisance from local sources.

Material and Deterioration Characteristic Analysis for Stone Sculptures in Gyeongbokgung Royal Palace, Seoul (경복궁 석조조형물의 재질 및 손상특성 분석)

  • Kim, Jiyoung;Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.407-420
    • /
    • 2013
  • The stone sculptures in Gyeongbokgung Royal Palace are mainly composed of granite (884 sculptures, 96.7%) and marble (25 sculptures, 2.7%) that originated in several different quarries. Main deterioration forms are crack (24%), break-out (21%), exfoliation (36%), granular disintegration (9%) and blackening (20%). Crack and break-out are dominant contributors to high physical deterioration degree, and blackening is major weathering form of intensive discoloration. The Gyeonghoeru, Geunjeongjeon and Pumgyeseok areas require urgent and high conservation maintenance with short-term periodic monitoring since proportions of 3-grade deterioration were calculated higher than others as 55% for Gyeonghoeru, 29% for Geunjeongjeon, 11% for Pumgyeseok area. The Pumgyeseok (officials' rank stone), especially, needs intervention for protective facility due to its material vulnerability to weathering in outdoor environment.

Fabrication and Verification of a Water Quality Sensor Equipped with Active RFID Function for Real Time Location (위치추적용 능동형 RFID 기능을 장착한 수질 측정 센서의 제작 및 검증)

  • Jung, Young-Sub;Chang, Hun;Kim, Jin-Young;Kang, Joon-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.113-120
    • /
    • 2009
  • Through the automatic sensing of the environment, USN technology can give the best services. In this work, we have developed an active RFID system and examined its performance. By implementing it into water quality sensors, we constructed a system that can detect diverse indoor/outdoor environment and provide information about the pollution level obtained from the temperature and PH sensors. Our RF system had an internal Print-on-PCB antenna for the miniaturization of the tag. We used a RF transceiver CC2510 chipset of TI company to realize the active RFID function. By using RSSI constants obtained, we performed the evaluation of real time location accuracy with a software written in Labview. Among 10 arbitrary locations, we obtained average measurement errors of 1.69 m in x axis and 1.66 m in y axis. This technology can be applied to logistics, environmental monitoring, prevention of missing children and various applications.

  • PDF

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Actual Conditions of Smoking of Public Workers within Nonsmoking Areas (공공기관 근무자의 금연구역내 흡연실태)

  • 백윤자;정문숙;권진희
    • Korean Journal of Health Education and Promotion
    • /
    • v.17 no.2
    • /
    • pp.229-237
    • /
    • 2000
  • The purpose of this study was to be useful in working out plans for improving national health by identifying public workers' knowledge of and attitude to smoking, actual conditions of smoking within nonsmoking areas, and related factors. For the purpose, the questionnaire was carried out with 761 public officials of the division manager-level and lower working in Taegu Metropolitan City Hall in september, 1998. The results are summarized as follows; Smokers of the subject group accounted for 55.1%, and the smoking rate had a significant relation with age and religion. In view of the time when smokers started smoking, smokers who started smoking after graduation from a high school accounted for 70.6%. Smokers who smoke one pack of cigarettes per day and a cigarette to its two-thirds length was the most. In the smoking place of smokers at home, 54.9% of the smokers responded that they smoke in an outdoor space The rate of smoking in an office was 68.3% and the rate of smoking within the nonsmoking areas of other public institutions was 43.0%. The results of multiple regression analysis with the actual state of smoking within the nonsmoking area of other public institutions as an independent variable revealed that smokers who check for a nonsmoking area before smoking in the public institutions and who do not smoke in an office do not smoke within the nonsmoking areas of other public institutions. In conclusion, more smoking and health education for public workers is needed to reduce the rate of national smoking and allow people to have a good smoking attitude, and it is required to arrange an institutional system who can strictly control public workers' smoking in their offices or public places and to stress a function of surveillance and monitoring by nonsmokers.

  • PDF

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Design and Implementation of a Micro-Modem for Underwater Acoustic Communications (수중 음향 통신을 위한 초소형 모뎀 설계 및 구현)

  • Jeon, Jun-Ho;Cho, Hun-Chul;Kim, Chang-Hwa;Ryuh, Young-Sun;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4B
    • /
    • pp.405-411
    • /
    • 2011
  • As the interest in ocean environment monitoring and ocean development has been increased, the need for researches on underwater wireless sensor network (UWSN) and low power consuming acoustic modem for UWSN has been arisen. In this paper, we design and implement a micro-modem equipped with a tiny and omnidirectional transducer for underwater acoustic communications. In addition, we make experiments in a water tank and a pond in order to verify the performance of the developed modem in terms of supply voltage and communication distance, and analyze the results. According to the outdoor experiments, the modem can send data wirelessly in underwater at a distance of 40 meter with a data rate of 200 bps and a bit error rate of $10^{-5}$ when the supply voltage is 12 V. Due to its small size, low power consumption and omnidirectional property, it is expected that the modem which is implemented in this paper could be utilized for various applications based on UWSN.

Concentration of Air Pollutants and Asthma in Taejon City (대전지역 대기오염물질농도와 천식 환자수의 관련성)

  • 서원호;장성실;권호자
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.80-90
    • /
    • 2000
  • To determine the effect of air pollutants in Taejon City, we used medical insurance claim data for asthma and the data monitored from telemetry system of Ministry of Environment for air pollutants and meteorological factors. From November 1st, 1997 to October 31th, 1998, 95,629 asthma patients were covered by medical insurance at Taejon City. Subjects were composed of 49,563 males (51.8%) and 46.336 females(48.2%), and among the subjects, the proportion under 15 years old was 62.8% of the total. During the study period, daily mean concentrations of each air pollutants-So2, No2, CO, O3 and TSP-were 9.8 ppb, 17.6 ppm, 1.414 pp, 17.3 ppb and 60.6 $\mu\textrm{g}$/㎥, respectively, which were lower than each of the environmental recommended exposure levels, Through the simple correlation analysis between each air pollutants and meteorological factors, O3 was positively correlated with temperature, but negatively with relative humidity. TSP, SO2, NO2, CO were negatively correlated with meteorological factors, and these air pollutants except O3 were positively correlated with each other, O3 was correlated with TSP positively but the others negatively. Estimating relative risks of each air pollutant with the baseline general additive model, daily mean concentrations of TSP(Lag 0, 1, 4, 5day) were significantly associated with the increase of the asthma admission. Two age subgroups, under 15 and 15~54 have shown various association of all air pollutants concentration with the asthma admission. However, in case of over 54 age subgroup, only TSP(Lag 0 day) among all air pollutants was associated with the asthma admission. Each of ambient outdoor pollutant concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations were much lower than the environmental recommended exposure levels. Therefore, continuous effort lowering air pollutant concentration and introducing an active environmental conservation policy should be implanted for preventing hazardous health effects. Considering major proportion of asthma admissions, high susceptibility and less confounding factors among the age subgroup under 15 will be a useful target population for assessing such health effect monitoring.

  • PDF

Mobile Ubiquitous Healthcare System Using Wireless Sensor Network (무선센서네트워크 기반의 모바일 유비쿼터스 헬스케어시스템)

  • Shin, Kwang-Sig;Yau, Chiew-Lian;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2107-2112
    • /
    • 2006
  • As growing up of elderly population, the interesting on healthcare system in normal life using W is increasing. An integrated u-healthcare service architecture with IEEE 802.11 and IEEE 802.15.4 based sensor network and code divisi(m multiple access(CDMA) public mobile telecommunication networks was designed and developed. Sensor nodes with electrocardiogram(ECG), body core temperature sensors are attached on the patients' body. The healthcare parameters are transferred to web server via CDMA mobile network or through existed LAN network. The existed LAN network is suggested to be used for continuous monitoring of patient's health status in hospital while mobile networks can be used for general purpose at home or outdoor where infra networks unavailable. This system enable healthcare personal to be able to continuously access, review, monitor and transmit the patients information whereever they are, whenever they want. And immediately check their status by using cellular phone and obtain detail information by communication with medical information server through CDMA. By using this developed integrated u-healthcare service architecture, we can monitor patients' health status for 24 hours.

Prediction of Concrete Corrosion using Electrodchemical Technique (전기화학적인 콘크리트 부식의 예측)

  • 이종권;박지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.80-83
    • /
    • 2002
  • The effect of chloride content on the corrosion of reinforced bar in concrete was studied. The mixing ratio of the concrete was 1 : 1.78 : 5.35 : 4.73 (water : content : ballast : sand). The studied chloride content was in the range of 0∼3.5 wt%. The corrosion potentials were measured in every week for two years. The copper-copper sulfate electrode (CSE) was employed as a reference electrode. After two years, the corroded structure was examined and compared to measured corrosion potential. Any visible difference was founded in the specimen located indoor and outdoor. The chloride concentration enhanced rusting and reinforced bar, shifting the potential to active range. The results showed good argument with Van daveer criteria. In 3.5 wt% chloride, the potential shifted belong -350 mV after 58week. Specimen in 1.75 wt% chloride, showed the potential between -200 mV∼-350 mV. However those in free chloride solution maintained above -200 mV for the studied period. It can the concluded that the chloride enhanced corrosion of rebar in concrete and the electrochemical potential can be a promising corrosion monitoring technique.

  • PDF