• Title/Summary/Keyword: Out-patient clinic

Search Result 310, Processing Time 0.035 seconds

Comparison of occurrence rate of the epileptiform discharge between awake EEG and sleep EEG in childhood epilepsy (소아청소년 간질 환자에서 수면 뇌파와 각성 뇌파의 간질파 발현율의 비교)

  • Jung, Yu Jin;Kwon, Kyoung Ah;Nam, Sang Ook
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.861-867
    • /
    • 2008
  • Purpose : We carried out this study to determine if there is any difference in the occurrence rate of the epileptiform discharge between awake EEG and sleep EEG and if there are any factors influencing on the occurrence rate of EEG. Methods : This study included 178 epileptic children who had visited neurology clinic of the department of pediatrics, Pusan National University Hospital from July 2005 to July 2006. The medical and EEG records of these children who had had both awake EEG and sleep EEG were reviewed. We analysed the occurrence rate of the epileptiform discharge between awake EEG and sleep EEG. We investigated the related clinical factors which included sex, seizure types, underlying causes, age at first seizure, antiepileptic drug (AED) medication, age at recording, and background activity. Results : Among 178 epileptic children, 91 patients (51.1%) showed epileptiform discharge in awake or sleep states, 10 patients (11.0%) abnormal only in awake, 40 patients (44.0%) abnormal only in sleep, 41 patients (45.0%) abnormal in both awake EEG and sleep EEG. The occurrence rate of sleep EEG was 81 of 178 patients (45.5%) which was more than that of the awake EEG (28.7%) (P<0.001). The occurrence rate of sleep EEG is more than that of the awake EEG regardless of sex and underlying causes. But there is no significant difference from awake EEG and sleep EEG in finding the epileptiform discharge in the patient with generalized seizure, younger than 5 years old at first seizure, younger than 10 years old at recording, no antiepileptic medication, and abnormal background activity. Conclusion : The sleep EEG is thought to be more helpful in the diagnosis of childhood epilepsy.

A Clinico-Statistical Analysis of Patient with Hoarseness in E.N.T. field (사성을 주소한 이비인후과 질환에 대한 임상적 관찰)

  • Lee, Sook-Ja;Kang, Young;Yoo, Bang-Hwan
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.6.2-7
    • /
    • 1977
  • Hoarseness, caused by any condition that interfers with normal phonatory function of larynx, is the most important symtom of the laryngeal disease. The air pollution is the serious social problom today due to irritation of the respiratory mucosa and secondary respiratory disease. It is significant to study whether, in resent years, the patients with complant of hoarseness has being increased or decreased, compare to past years. The authors report a statistical analysis on 400 cases with chief complain of horseness at the Department of Otolaryngology, Hanil Hospital during past 7 years from Jan. I, 1970 to Dec. 31, 1976. The results were as follows; 1) Among total out patients of 14, 731 who visited to the department of otolaryngology, the patients with hoarseness numbered to 400(2.7%). 2) Among total of 400 cases, male were 211 and female were 189. The incidence was slightly higher in male than female with ratio 1.1 to 1 in sex distribution. 3) The uderlying diseases causing hoarseness in order of frequency were Acute Laryngitis (158 cases, 39.5%), Chronic Laryngitis (103 cases, 27.3 %), Vccal Nodule (37 cases, 9.3%), Vocal cord paralysis (34 cases, 8.5%), Laryngeal Polyp (32 cases, 8%), Laryngeal Ca. (13 cases, 3.5%), and Laryngeal Tbc. (9 cases, 2.3%). Particulary, Laryngeal Ca., Laryngeal polyp and Laryngeal Papilloma were extremely high in male but the remainings were equally distributed in sex group distribution. 4) The highest incidence occurred in 3rd decade (113 cases, 28.5%), the next 4th and 2nd decade in the age group distribution. Acute and Chronic Laryngitis were widely distributed in age group distribution but the highest incidence was noted between 3rd and 4th decade (145 cases, 55.5%). The highest incidence was 3rd decade in Laryngeal polyp, 3rd and 4th decade in Vocal Nodule, 4th and 5th decade in Laryngeal Tbc. and Vocal cord paralysis and 5th decade in Laryngeal Ca. 5) The underlying disease causing hoarsness were evenly occurred in monthly distribution but relatively high incidence was observed between April and June (35.5%) compared to winter. 6) In durational distribution, the highest incidence was within 10 days (26%) from onset to consultation. 317 cases (80%) were visited to the clinic within 1 year.

  • PDF

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Effectiveness of MDCT for the Followup of CABG Patients with LIMA to LAD and Saphenous Veins to Others (좌내흉동맥과 복재정맥편을 사용한 관상동맥우회로술 환자에서의 추적조사에서 MDCT의 유용성)

  • Kang Joon Kyu;Kim Hyung Tai;Park In Duk;Chung Young Mi;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.410-414
    • /
    • 2005
  • There are several options for choosing a graft in CABG, we routinely chose LIMA for LAD and great saphenous vein for other target vessels. To evaluate the posoperative graft patency, we have studied the results using a 16 slices multi-detector computed tomography. Material and Method: From 1995 to 2003, 80 CABG patients who did not complain any event of MACE have been examined by 16-MDCT, mostly in an out patient clinic. Result: There were 61 men and 19 women. MDCT was used as early as 7 days to 9 years post-operatively with a median follow-up period of 6.5 years, and mean follow-up peiod of $31.5\pm25.4$ months. Mean age was $58.4\pm12.6$ years old in men and $61.5\pm17.2$ years old in women. 72180 patients received LIMA to LAD, and all other patients received vein grafts for bypass. The target vessel of vein grafts were 8 in LAD, 47 in RCA, 60 in diagonals, and 61 in obtuse marginals. Among them 42 sequential anastomoses were performed. The mean graft number was $3.1\pm1.8$ grafts. 5 year graft patency rate of each grafts was as followings; $93.1\%$ in LIMA to LAD, $94.9\%$ in vein to diagonals, $92.1\%$ in vein to obtuse marginals, and $79.2\%$ in vein to RCA. Sequential grafting showed better graft patency than the isolated grafting $(95.2\%\;vs\;78.7\~95.0\%)$. Conclusion: In this study, CABG with LIMA and saphenous veins showed satisfactory longterm results. 16-MDCT provided good images for follow-up study after CABG. Additionally, as radiologic tools (64-MDCT, MRI) improve more in the future, they can be used for diagnosing preoperative anatomical coronary disease as well as cardiac functions.

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.

A Study on Fall Accident (1개 종합병원 환자의 낙상에 관한 조사)

  • Lee, Hyeon-Suk;Kim, Mae-Ja
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.45-62
    • /
    • 1998
  • The study was conducted from November 1995 to May 1996 at the one general hospital in Seoul. The total subjects of this study were 412 patients who have the experience of fall accident, among them 31 was who have fallen during hospitalization and 381 was who visited emergency room and out patient clinic. The purposes of this study were to determine the characteristics, risk factors and results of fall accident and to suggest the nursing strategies for prevention of fall. Data were collected by reviewing the medical records and interviewing with the fallers and their family members. For data analysis, spss/pc+ program was utilized for descriptive statistics, adjusted standardized $X^2$-test. The results of this study were as follows: 1) Total subjects were 412 fallers, of which 245(59.5%) were men and 167(40.5%) were women. Age were 0-14 years 79(19.2%), 15-44 years 125(30.4%), 45-64 years 104(25.2%), over 65 years 104(25.2%). 2) There was significant association between age and the sexes ($X^2$=39.17, P=0.00). 3) There was significant association between age and history of falls ($X^2$=44.41. P= .00). And history of falls in the elderly was significantly associated with falls. 4) There was significant association with age and medical diagnosis ($X^2$=140.66, P= .00), chief medical diagnosis were hypertension(34), diabetis mellitus(22), arthritis(11), stroke(8), fracture(7), pulmonary tuberculosis(6), dementia(5) and cataract(5), 5) There was significant association between age and intrinsic factors: cognitive impairment, mobility impairment, insomnia, emotional problems, urinary difficulty, visual impairments, hearing impairments, use of drugs (sedatives , antihypertensive drugs, diuretics, antidepressants) (P < 0.05). But there was no significant association between age and dizziness ($X^2$=2.87, P=.41). 6) 15.3% of total fallers were drunken state when they were fallen. 7) Environmental factors of fall accident were unusual posture (50.9%), slips(35.2%), trips (9.5%) and collision(4.4%). 8) Most of falls occurred during the day time, peak frequencies of falls occurred from 1pm to 6pm and 7am to 12am. 9) The places of fall accident were roads(22.6%), house-stairs 06.7%), rooms, floors, kitchen (11.2%), the roof-top, veranda, windows(10.9%), hospital(7.5%), ice or snowy ways(5.8%), bathroom(4.9%), playground, park(4.9%), subway-stairs(4.4%) and public-bathrooms (2.2%). 10) Activities at the time of fall accident were walking(37.6%), turning around or reaching for something(20.9%), going up or down stairs09.2%), exereise, working07.4%), up or down from a bed(2.7%), using wheelchair or walking aids, standing up or down from a chair(2.2%) and standing still(2.2%). 11) Anatomical locations of injuries by falls were head, face, neck(31.3%), lower extremities (29.9%). upper extremities(20.6%), spine, thorax, abdomen or pelvic contents(l1.4%) and unspecified(2.9%). 12) Types of injures were fracture(47.6%), bruises03.8%), laceration (13.3%), sprains(9.0%), headache(6.6%), abrasions(2.9%), intracranial hemorrage(2.4%) and burns(0.5%). 13) 41.5% of the fallers were hospitalized and average of hospitalization was 22.3 days. 14) The six fallers(1.46%) died from fall injuries. The two fallers died from intracranial hemorrage and the four fallers died of secondary infection; pneumonia(2), sepsis(1) and cell lulitis(1). It is suggested that 1) Further study is needed with larger sample size to identify the fall risk factors. 2) After the fall accident, comprehensive nursing care and regular physical exercise should be emphasized for the elderly person. 3) Safety education and safety facilities of the public place and home is necessary for fall prevention.

  • PDF

Multi-Institute, Single Group, Prospective Observational Study to Evaluate the Efficacy of Mucomyst® in Relieving Symptoms of Globus Pharyngeus Refractory to Proton Pump Inhibitor (양성자펌프억제제에 반응하지 않는 인두이물감 환자에서 "뮤코미스트Mucomyst®" 객담제거 및 상기도 염증치료를 통한 증상개선효과 평가 다기관, 단일군, 전향적 관찰 연구)

  • Park, Hannah;Park, Il-Seok;Lee, Sang Hyuk;Lee, Seung-Won;Lee, Sang Joon;Lee, Byung-Joo;Cheon, Yong-Il;Park, Jun-Ook;Oh, Kyoung Ho;Shin, Yoo Seob
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.1
    • /
    • pp.20-25
    • /
    • 2022
  • Background and Objectives Globus pharyngeus is one of the most common symptoms of patients visiting otorhinolaryngology out-patient clinic, and usually long-lasting, difficult to treat, and frequently recurrent. Mucomyst®, N-acetyl cysteine is an inhalation agent mainly used for mucolysis and reducing inflammation in airway via antioxidative effect. The purpose of this study was to evaluate the efficacy of inhaled Mucomyst® treatment in patients with globus pharyngeus refractory to proton pump inhibitor (PPI). Materials and Method We prospectively evaluated the efficacy of Mucomyst® in relieving symptoms of globus pharyngeus refractory to PPI in nine medical centers. Three hundred and three patients enrolled and finally 229 patients finished the inhaled Mucomyst® therapy for 8 weeks. We analyzed the change of Reflux Symptom Index (RSI), Reflux Finding Score (RFS), Visual Analogue Scale (VAS) for globus, and Globus Pharyngeus Symptom Scale (GPS) after use of Mucomyst® for 4 and 8 weeks. Results The GPS, RSI, RFS, and VAS score significantly decreased serially in patients who finished 8 week-inhalation treatment. The GPS improvement gap was significantly correlated with initial GPS (p<0.001) in multiple regression analysis. Conclusion Inhaled Mucomyst® therapy was effective for the reduction of both subjective and objective findings in refractory globus patients. This study might suggest new treatment option for patients with globus. However, further thorough studies would be needed to assess the real effect of inhaled Mucomyst® treatment as a standard treatment for globus.

Clinical Features of Acute Nonspecific Mesenteric Lymphadenitis and Factors for Differential Diagnosis with Acute Appendicitis (급성 비특이성 장간막 림프절염의 임상 소견과 급성 충수돌기염과의 감별 인자)

  • Shin, Kyung Hwa;Kim, Gab Cheol;Lee, Jung Kwon;Lee, Young Hwan;Kam, Sin;Hwang, Jin Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • Purpose: Although acute nonspecific mesenteric lymphadenitis (ANML) is probably common cause of abdominal pain in children, which can be severe enough to be an abdominal emergency, the clinical features of mesenteric lymphadenitis are not clear. Also, a differential diagnosis with acute appendicitis (APPE) is indispensable to avoid serious complications. The clinical features of ANML were determined, and the risk factors for differential diagnosis with APPE were analyzed. Methods: Between November 2000 and May 2001, data from 26 patients (aged 1 to 11 years) with ANML and 21 patients (aged 2 to 13 years) with APPE were reviewed. ANML was defined as a cluster of five or more lymph nodes measuring 10 mm or greater in their longitudinal diameter in the right lower quadrant (RLQ) without an identifiable specific inflammatory process on the ultrasonographic examination. There were risk factors on patient's history, physical examination, and laboratory examination; the location of abdominal pain, abdominal rigidity, rebound tenderness, fever, nocturnal pain, the vomiting intensity, the diarrhea intensity, the symptom duration, and the peripheral blood leukocytes count. Results: Of the 26 ANML patients and 21 APPE patients, abdominal pain was noted on periumbilical (76.9% vs 14.2%), on RLQ (11.5% vs 71.4%), with abdomen rigidity (7.6% vs 80.9%), with rebound tenderness (0.0% vs 76.1%)(p<0.05), in the lower abdomen (11.5% vs 14.2%), and at night (80.8% vs 100.0%) (p>0.05). The clinical symptoms were vomiting (38.4% vs 90.4%), the vomiting intensity ($1.5{\pm}0.7$ [1~3]/day vs $4.5{\pm}2.9$ [1~10]/day), diarrhea (65.3% vs 28.5%) (p<0.05), and fever (61.5% vs 76.2%)(p>0.05). The period to the subsidence of abdominal pain in the ANMA patients was $2.5{\pm}0.5$ (2~3) days. The laboratory data showed a significant difference in the peripheral blood leukocytes count ($8,403{\pm}1,737[5,900{\sim}12,300]/mm^3\;vs\;15,471{\pm}3,749[5,400{\sim}20,800]/mm^3$)(p<0.05). Discriminant analysis between ANML and APPE showed that the independent discriminant factors were a vomiting intensity and the peripheral blood leukocytes count and the discriminant power was 95.7%. Conclusion: The clinical characteristics of ANML were abrupt onset of periumbilical pain without rigidity or rebound tenderness, a mild vomiting intensity, normal peripheral leukocytes count, and relatively short clinical course. If the abdominal pain persist for more than 3 days, and/or the vomiting intensity is more than 3 times/day, and/or the peripheral leukocytes count is over $13,500/mm^3$, abdominal ultrasonography is recommended to rule out APPE.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF