• Title/Summary/Keyword: Osstell

Search Result 42, Processing Time 0.022 seconds

Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant (수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교)

  • Lim, Hyoung-Sup;Kim, Su-Gwan;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

ORIGINAL ARTICLE - Analysis of RFA related to stabilities by types and areas of dental implants (ORIGINAL ARTICLE - 임플란트 종류 및 식립부위에 따른 안정성에 대한 RFA 분석)

  • Yi, Hee-Yong;Park, Min-Ju;Cho, Hyun-Jae;Yu, Ki-Jun;Ha, Jung-Eun;Baek, Dae-Il;Bae, Gwang-Hak
    • The Journal of the Korean dental association
    • /
    • v.50 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • Objective : This research compared stabilities between two types of dental implant ($SLA^{TM}$, Institut Straumann AG, Waldenburg, Switzerland and $SSII^{TM}$, Osstem co, Busan, Korea) using Osstell Mentor (Integration Diagnostics AB, Goteborg, Sweden) considering surgery methods, surgery area, diameter of implant, systemic disease, and smoking for obtaining prognosis information when installing fixture of dental implant. Materials & Methods : 206 implants of 131 patients taken by resonance frequency analysis (RFA) were determined as a final sample. Dental implants were installed as protocol of supplier by a excellent dentist who had 10 years experience about dental implants. Before connecting abutments (3 months after installation of fixture), RFA were measured twice for buccal and lingual direction to obtain average value. Results : Dental implants at mandible showed significantly higher stabilities significantly than at maxilla (p<0.001). Diameter 4.8 implants had also higher stabilities than diameter 4.1 in case of $SLA^{TM}$ implants (p<0.001). $SLA^{TM}$ implants showed more excellent stabilities than $SSII^{TM}$ implants, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032). Conclusions : This research revealed higher stabilities of $SLA^{TM}$ implants than $SSII^{TM}$ implant, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032).

Retrospective clinical study of ultrawide implants more than 6 mm in diameter

  • Ku, Jeong-Kui;Yi, Yang-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.30.1-30.6
    • /
    • 2016
  • Background: The prognosis of wide implants tends to be controversial. While wider implants were initially expected to result in a larger osseointegration area and have higher levels of primary stability, they were reported to have a relatively high rate of failure. The clinical outcome of ultrawide implants of more than 6 mm in diameter was evaluated through a retrospective study. Methods: The investigation was conducted on patients who had received ultrawide implant (${\geq}6mm$ diameter) placements in Seoul National University Bundang Hospital from January 2008 to December 2013. Complications were investigated during the maintenance period, and marginal bone loss was measured using periapical radiography. Primary stability immediately after the implant placement and second stability after second surgery or during impression were measured using $Osstell^{(R)}$ Mentor (Osstell, Sweden) as an implant stability quotient (ISQ). Results: Fifty-eight implants were placed in 53 patients (30 male, 23 female), and they were observed for an average of $50.06{\pm}23.49$ months. The average ISQ value increased from $71.22{\pm}10.26$ to $77.48{\pm}8.98$ (P < 0.005). The primary and secondary stability shows significantly higher at the mandible than at the maxilla (P < 0.001). However, mean survival rate shows 98.28 %. Average marginal bone loss of 0.018 and 0.045 mm were measured at 12 and 24 months after the loading and 0.14 mm at final follow-up date (mean 46.25 months), respectively. Also in this study, the bone loss amount was noticeably small compared to regular implants reported in previous studies. Conclusions: The excellent clinical outcome of ultrawide implants was confirmed. It was determined that an ultrawide implant can be used as an alternative when the bone quality in the posterior teeth is relatively low or when a previous implant has failed.

The rate and stability of mandibular block bone graft in recent 5 years

  • Park, Jong-Cheol;Kim, Yun-Ho;Choi, Hong-Seok;Oh, Jong-Shik;Shin, Sang-Hun;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.21.1-21.6
    • /
    • 2017
  • Background: The purposes of the present study were to compare implant stabilities of mandibular block bone graft and bovine bone graft and to evaluate influencing factors for implant stability in mandibular block bone (MBB) graft. Methods: This retrospective study investigated 1224 cases and 389 patients treated by one surgeon in the Department of Oral and Maxillofacial Surgery of Pusan National University Dental Hospital (Yangsan, Korea) between January 2010 and December 2014. Proportions that MBB graft cases constitute in all implant restoration cases and in all bone graft cases were measured. Implant stability quotient (ISQ) values were achieved by the same surgeon before loading. The average ISQ values of the experimental groups were compared. In addition, ISQ values of influencing factors, such as age, sex, implant size, and implant placement site, were compared within the MBB group using $Osstell^{TM}$ Mentor ($Osstell^{(R)}$, $G{\ddot{o}}teborg$, Sweden). Paired t test and ANOVA were conducted for statistical analysis with a significance level of 0.05. Results: Fifty-five percent of all implant restoration cases performed bone graft while MBB cases constituted 34% of all implant restoration cases and 61% of all bone graft cases. Comparing ISQ values according to bone graft materials, the MBB group manifested sufficient implant stability by presenting comparable ISQ value to that of the experimental group without bone graft. Among the reviewed factors, females, mandibular molar regions, and implants in larger diameter displayed greater implant stabilities. Conclusions: Satisfactory implant stability was accomplished upon administration of MBB graft. Within the limitation of this study, gender, implant site, and implant diameter were speculated to influence on implant stability in MBB graft.

THE INFLUENCING FACTORS OF $PERIOTEST^(R)$ VALUE AND IMPLANT STABILITY QUOTIENT ($Periotest^(R)$ Value와 Implant Stability Quotient에 영향을 미치는 요소)

  • Yi Young-Ah;Cha In-Ho;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.40-50
    • /
    • 2006
  • Statement of problem: $Periotest^(R)\;and\;Osstell^{TM}$ were known as the most objective and quantitative mobility tests available for evaluating stability of implant in vivo. Although a correlation between PTV widely used and ISQ recently introduced exist, a PTV was corresponded to various ISQ. A correct evaluation of implant stability could be obtained only after one has a thorough understanding of the limitations of devices and factors that affect measurements. Purpose: The purpose of this study was to investigate the causes of variables in the values obtained with these two tests. Material and method: A total of 333 implants 134 $Br{\aa}nemark$, 5 Silhouette and 194 ITI implants were investigated. Result: 1. There was a correlation between PTV and ISQ (Spearman correlation =0.39, p<0.0001) 2. The factors that affected ISQ were diameter of implant future, location of implant and implant system (submerged type vs non-submerged type). 3. The factors that affected W were dimeter of implant future, location of implant, and elapsed time after implant placement. 4. There was no significant difference between different surface treatments of RBM, smooth surface and ti-unite on PTY and ISQ. 5. In radiographic finding, no saucerization or bone resorption has been detected in implants with ISQ values that were above the average level of each PTV. These higher values had higher bone densities around the implant fixture. Saucerization was observed in the most impants with ISQ values that were below the average level of each PTV. Conclusion: There was a correlation between ISQ and PTV. However, each measuring methods had factors influencing the measured values. PTV were less sensitive to marginal bone resorption and influenced with the striking point on an implant to the level of bone. With ISQ, the height of implant from bone level to transducer should be considered.

The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement (임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구)

  • Choi, Yu-Sung;Kim, Eun-Kyung;Kim, Se-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the changes in bone density and reduction of time consumed for osteogenesis by $PostPlant^{TM}$ Calcium and to find out efficacy of $PostPlant^{TM}$ Calcium by comparing the group prescribed with $PostPlant^{TM}$ Calcium with the group without $PostPlant^{TM}$ Calcium prescription. Material and methods: The experimental group of 18 patients with 25 dental implant placement and the control group of 7 patients with 9 dental implant placement were randomly selected from the patients who visited prosthetic department of Dankook University Dental Hospital since July, 2006 (IRB Number ; 20060710). The experimental group was instructed to take $PostPlant^{TM}$ Calcium for 6 months after the implant surgery while the control group was instructed not to. Both experimental and control group were assigned for measurement using $Osstell^{TM}$ Mentor and $Periotest^{(R)}$ and radiographic examination was performed using specifically manufactured Aluminum Step Wedge. The results were compared and analyzed. Results: 1. According to the $Osstell^{TM}$ Mentor measurement, both the experimental and control group showed increase in values as time elapses and the experimental group showed significantly higher rate of increase (P < .05). 2. According to the $Periotest^{(R)}$ measurement, both the experimental and control group showed decrease in values as time elapses. In addition, greater decrease can be seen in the experimental group but no statistical significance was found. 3. By examining the radiographic images, both the experimental and control group showed tendency of increase in bone density. In addition, greater increase can be seen in the experimental group but no statistical significance was found. Conclusion: Clinically, taking $PostPlant^{TM}$ Calcium medicine for a long period of time after implant placement is expected for a better prognosis.

Experimental Study of Osseointegration and Stability of Intentionally Exposed Hydroxyapatite Coating Implants (의도적으로 연조직에 노출시킨 수산화인회석 코팅 임플란트의 골유착과 안정성에 대한 실험적 연구)

  • Jeong, Kyung-In;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Jo, Ji-Ho;Lim, Hyoung-Sup;Kim, Jeong-Sun;Lim, Sung-Chul;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the effect of exposure of hydroxyapatite coating on the amount of bone formation and stability in the dogs. Methods: In this study, hydroxyapatite coated implants (HAPTITE) was placed over the femur bone surface of four dogs about 1 mm. The experimental group was divided into 4 weeks group of 8 implants and 8 weeks group of 8 implants, and then they were sacrificed. The stability of implants was evaluated twice with Osstell$^{TM}$ mentor (Osstell AB, Goteborg, Sweden) at right after placement and sacrifice. The amount of bone formation was evaluated through histomorphometric examination. Results: The stability of implants was in normal range, and tended to increase as time goes by. Mean percentages of new bone formation rates were $90.5{\pm}6.6$ at uppermost 1 mm bone level adjacent to soft tissues (level 1) and $92.9{\pm}4.1$ at next 1 mm bone level (level 2) in 4 weeks group, $90.1{\pm}11.5$ at level 1 and $95.9{\pm}2.3$ at level 2 in 8 weeks group. Mean percentages of bone-implant contact rates were $85.1{\pm}10.8$ at level 1 and $88.1{\pm}13.8$ at level 2 in 4 weeks group, $88.5{\pm}14.4$ at level 1 and $95.3{\pm}3.1$ at level 2 in 8 weeks group. There was no statistically significant difference of new bone formation rate and bone-implant contact rate between uppermost 1 mm bone level adjacent to soft tissues and next 1 mm bone level. However, there was no significant difference in bone formation between 4 and 8 weeks groups. Conclusion: These results suggested that exposed hydroxyapatite coated implants to soft tissue showed favorable bone formation and implant stability.

In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material

  • Kwak, Mu-Seung;Kim, Seok-Gyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.428-433
    • /
    • 2013
  • PURPOSE. The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. MATERIALS AND METHODS. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with ${\phi}5.0mm{\times}13.0mm$ were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (${\alpha}$=.05) were done for statistical analysis. RESULTS. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. CONCLUSION. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.

IN VITRO COMPARATIVE STUDY BETWEEN ISQ AND $PERIOTEST^{(R)}$ VALUES ON THE IMPLANT STABILITY MEASUREMENTS ACCORDING TO THE INCREASED EFFECTIVE IMPLANT LENGTH

  • Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.625-632
    • /
    • 2001
  • Statement of Problem. Objective and quantitative measurement of implant stability is very important from implant installation to long-lasting maintenance period thereafter. Purpose of study. This study was to evaluate and compare two ISQ and PTVs on the implant stability measurements according to the increased effective implant length. Materials and methods. Twenty self-tapping fixtures were installed in the bovine scapula and in 10 of those for group I, ISQ and PTVs were obtained in the vertical/horizontal directions according to the increased effective implant length using $Osstell^{TM}$ and $Periotest^{(R)}$. After stability measurement, removal torques were measured between the after installation and after thread exposure group. Results. ISQ and PTVs showed decreased and increased values according to the increased abutment length. Apart from PTVs, ISQ values were shown higher in horizontal direction to the long axis of bone in both the after installation and the after thread exposure groups. Removal torque values were shown higher in after installation group. Conclusion. From the results of this study, implant stability measurement using resonance frequency analysis was more sensitive and discriminative than PTVs measurement.

  • PDF

Clinical Study on the Efficacy of the Autogenous Tooth Bone Graft Material (AutoBT) (자가치아 뼈 이식재의 유용성에 관한 임상적 연구)

  • Han, Min Woo;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.4
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study is to evaluate the efficacy of the autogenous tooth bone graft material, clinically and radiologically, as related to implant installation. Methods: In oral and maxillofacial surgery department of Ajou University Hospital, guided bone regeneration (GBR), implant placement combined with GBR, sinus graft, implant placement combined with sinus graft, and defect filling were performed in 46 patients, using autogenous tooth bone. Among these, 66 implants were inserted with autogenous tooth bone. Implant stability quotient (ISQ) was measured by Osstell Mentor (Integration Diagnostics, Goteborg, Sweden) on 39 implants on the operation date and 4 months later, and on 21 implants 9months on the average at the final setting of restoration. Twenty-eight implants with GBR and sinus graft (GBR group: n=14, sinus graft group: n=14) were evaluated radiologically to measure the resorption of grafted autogenous tooth bone after loading. Results: The average initial stabilization of the installed implants was 67 ISQ, and the average secondary stabilization at 4 months later was 76. The average bone loss of GBR group as measured 8.0 months after application of prosthesis loading was 0.29 mm and the average bone loss of the sinus graft group as measured 7.6 months after application of prosthesis loading was 0.66 mm, respectively. In the histological assessment, formation of the new bone and continuous trabecular bone pattern was identified around autogenous tooth bone. Conclusion: Based on these results, we concluded that autogenous tooth bone is an excellent bone graft material that can substitute the autogenous bone.