Design and Performance Analysis of the Interface Middleware for Embedded Systems (임베디드 시스템 인터페이스용 미들웨어 설계 및 성능분석)

  • Kim, Myoung-Sun;Lee, Su-Won;Lee, Cheol-Hoon;Choi, Hoon;Cho, Kil-Seok
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.52-62
    • /
    • 2008
  • As various types of embedded devices are widely used, a technology that supports reuse of applications on multiple platforms is needed in order for time-to-market development of the applications. The interface middleware is one of such technology and it hides platform dependency from application programmers. Existing interface middleware such as the MT project, Xenomai and Legacy2linux have limitation in that the APIs provided by each of these middleware are fixed to a specific operating system, and the middleware does not provide dynamic expansion of its API set. In this paper, we propose a middleware which hides operating system dependencies and enables porting of applications on various operating systems. In addition, the middleware has scalable structure so that it is suitable for resource-limited embedded systems. The overhead of the middleware, i.e., the time delay occurred by the middleware is between $0.3{\mu}sec\;and\;5{\mu}sec$ in most cases. We believe that the amount of overhead is reasonable and does not hurt the performance of applications.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

Interface Development for the Point-of-care device based on SOPC

  • Son, Hong-Bum;Song, Sung-Gun;Jung, Jae-Wook;Lee, Chang-Su;Park, Seong-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This paper describes the development of the sensor interface and driver program for a point of care (POC) device. The proposed pac device comprises an ARM9 embedded processor and eight-channel sensor input to measure various bio-signals. It features a user-friendly interface using a full-color TFT-LCD and touch-screen, and a bluetooth wireless communication module. The proposed device is based on the system on a programmable chip (SOPC). We use Altera's Excalibur device, which has an ARM9 and FPGA area on a chip, as a test bed for the development of interface hardware and driver software.

A Design and Implementation of Windows CE Boot Loader to support Compact Flash (컴팩트 플래시 지원을 위한 Windows CE 부트로더의 설계 및 구현)

  • Pi Mu-ho;choi Jong-pil;Kong Ki-sok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.931-933
    • /
    • 2005
  • Windows CE는 Microsoft사의 Windows 운영체제 가운데서 가장 작은 운영체제로서 일반 데스크톱 Windows 커널을 수용할 수 없는 소형/임베디드 장비에서 주로 사용되어진다. 현재 Windows CE에서 사용되고 있는 부트로더로는 E-boot(Ethernet bootloader)가 있으며 RAM 이미지와 플래시 이미지 다운로드 기능을 제공한다. E-boot의 문제점으로는 플래시 메모리상에서 부팅을 수행하기 때문에 NOR 타입의 플래시만을 지원하여, 컴팩트 플래시와 같은 NAND 타입의 플래시 지원하지 않는다. 이는 OS Binary 이미지의 용량이 NOR 플래시를 초과할 경우에 수행이 불가능하다는 문제를 발생시킨다. 따라서 본 논문에서는 기존의 E-boot를 수정하여 NDR 플래시보다 상대적으로 가격이 저렴하고 휴대성이 좋은 컴팩트 플래시 메모리를 이용하여 부팅이 가능한 부트로더를 구현한다. 또한 컴팩트 플래시 지원을 위한 새로운 읽기/쓰기 메카니즘을 소개한다.

  • PDF

A Platform-Based SoC Design of a 32-Bit Smart Card

  • Kim, Won-Jong;Kim, Seung-Chul;Bae, Young-Hwan;Jun, Sung-Ik;Park, Young-Soo;Cho, Han-Jin
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.510-516
    • /
    • 2003
  • In this paper, we describe the development of a platform-based SoC of a 32-bit smart card. The smart card uses a 32-bit microprocessor for high performance and two cryptographic processors for high security. It supports both contact and contactless interfaces, which comply with ISO/IEC 7816 and 14496 Type B. It has a Java Card OS to support multiple applications. We modeled smart card readers with a foreign language interface for efficient verification of the smart card SoC. The SoC was implemented using 0.25 ${\mu}m$ technology. To reduce the power consumption of the smart card SoC, we applied power optimization techniques, including clock gating. Experimental results show that the power consumption of the RSA and ECC cryptographic processors can be reduced by 32% and 62%, respectively, without increasing the area.

  • PDF

The Optimal Limit of the Number of COnsecutive Minimal Repairs

  • Jongho Bae;Lee, Eui-Yong
    • Journal of the Korean Statistical Society
    • /
    • v.30 no.1
    • /
    • pp.89-98
    • /
    • 2001
  • Brown and Proschan(1983) introduced a model for imperfect repair. At each failure of a device, with probability p, it is repaired completely or replaced with a new device(perfect repair), and with probability 1-p, it is returned to the functioning state, but it is only recovered to its condition just prior to failure(imperfect repair or minimal repair). In this paper, we limit the number of consecutive minimal repairs by n. We find some useful properties about $\mu$$_{k}$, the expected time between the k-th and the (k+1)-st repair under he assumption that only minimal repairs are performed. Then, we assign cost to each repair and find the value of n which minimized the long-run average cost for a fixed p under the condition that the life distribution F os the device is DMRL.L.

  • PDF

Research about VOD Client that use Internal net (Internet망을 이용한 VOD Client에 관한 연구)

  • Seo, Seung-Beom;Hong, Cheol-Ho;Sin, Dong-Uk;Kim, Seon-Ju;Lee, Mu-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.211-214
    • /
    • 2003
  • Current VOD embodiment way is embodied using PC base. However, achieved research that embody this by Embedded System that PC base is not. OS of this system used WindowsCE.net and x86core used having built-ined SC1200(National company's Geode's familys) by CPU and memory used 128MByte SDRAM. Used Mpeg Decoder for processing of video data, and used Enthernet Controller for Internet. Composite, component, S-Video of video output section of this system is and select one of these and connect on TV and did so that get into action. Actuality implementation manufactured necessary BIOS, WinodwsCE.NET Porting, DeviceDriver in system development and necessary simple Application in action confirmation, and Video Player used Window Media Player had included to WindowsCE.net. Therefore, treatise that see to supplement shortcomings of VOD service been embodying in current PC in Embedded System's form embody that there is sense do can.

  • PDF

Clinical Outcomes of Basaloid Squamous Cell Carcinoma of the Esophagus: A Retrospective Analysis of 142 Cases

  • Zhang, Bai-Hua;Cheng, Gui-Yu;Xue, Qi;Gao, Shu-Geng;Sun, Ke-Lin;Wang, Yong-Gang;Mu, Ju-Wei;He, Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1889-1894
    • /
    • 2013
  • Background: Basaloid squamous cell carcinoma of the esophagus (BSCCE) is a rare and distinctive tumor with no standard treatment. This study aimed to explore treatment in relation to prognosis of the disease. Methods: A total of 142 patients with BSCCE that underwent treatment in our hospital from March 1999 to July 2010 were retrospectively analyzed. All patients received surgery, 42 postoperative radiotherapy and 28 patients chemotherapy. Results: There were 26 patients included in stage I, 60 in stage II, 53 in stage III and 3 in stage IV. The clinical symptoms and macroscopic performances of BSCCE did not differ from those of typical esophageal squamous cell carcinoma. Among 118 patients receiving endoscopic biopsy, only 12 were diagnosed with BSCCE. The median survival time (MST) of the entire group was 32 months, with 1-, 3- and 5-year overall survival (OS) of 81.4%, 46.8% and 31.0%, respectively. The 5-year OS of stage I and II patients was significantly longer than that of stages III/IV, at 60.3%, 36.1% and 10.9%, respectively (p<0.001, p=0.001). The MST and 5-year OS were 59.0 months and 47.4% in patients with tumors located in the lower thoracic esophagus, and 27.0 months and 18.1% in those with lesions in the upper/middle esophagus (p=0.002). However, the survival was not significantly improved in patients undegoing adjunctive therapy. Multivariate analysis showed TNM stage and tumor location to be independent prognostic factors. Furthermore, distant metastasis was the most frequent failure pattern, with a median recurrence time of 10 months. Conclusion: BSCCE is an aggressive disease with rapid progression and a propensity for distant metastasis. It is difficult to make a definitive diagnosis via preoperative biopsy. Multidisciplinary therapy including radical esophagectomy with extended lymphadenectomy should be recommended, while the effectiveness of radiochemotherapy requires further validation for BSCCE.

Immune Checkpoint Inhibitors for Non-Small-Cell Lung Cancer with Brain Metastasis : The Role of Gamma Knife Radiosurgery

  • Lee, Min Ho;Cho, Kyung-Rae;Choi, Jung Won;Kong, Doo-Sik;Seol, Ho Jun;Nam, Do-Hyun;Jung, Hyun Ae;Sun, Jong-Mu;Lee, Se-Hoon;Ahn, Jin Seok;Ahn, Myung-Ju;Park, Keunchil;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.271-281
    • /
    • 2021
  • Objective : Immune checkpoint inhibitors (ICIs) are approved for treating non-small-cell lung cancer (NSCLC); however, the safety and efficacy of combined ICI and Gamma Knife radiosurgery (GKS) treatment remain undefined. In this study, we retrospectively analyzed patients treated with ICIs with or without GKS at our institute to manage patients with brain metastases from NSCLC. Methods : We retrospectively reviewed medical records of patients with brain metastases from NSCLC treated with ICIs between January 2015 and December 2017. Of 134 patients, 77 were assessable for brain responses and categorized into three groups as follows : group A, ICI alone (n=26); group B, ICI with concurrent GKS within 14 days (n=24); and group C, ICI with non-concurrent GKS (n=27). Results : The median follow-up duration after brain metastasis diagnosis was 19.1 months (range, 1-77). At the last follow-up, 53 patients (68.8%) died, 20 were alive, and four were lost to follow-up. The estimated median overall survival (OS) of all patients from the date of brain metastasis diagnosis was 20.0 months (95% confidence interval, 12.5-27.7) (10.0, 22.5, and 42.1 months in groups A, B, and C, respectively). The OS was shorter in group A than in group C (p=0.001). The intracranial disease progression-free survival (p=0.569), local progression-free survival (p=0.457), and complication rates did not significantly differ among the groups. Twelve patients showed leptomeningeal seeding (LMS) during follow-up. The 1-year LMS-free rate in treated with ICI alone group (69.1%) was significantly lower than that in treated with GKS before ICI treatment or within 14 days group (93.2%) (p=0.004). Conclusion : GKS with ICI showed no favorable OS outcome in treating brain metastasis from NSCLC. However, GKS with ICI did not increase the risk of complications. Furthermore, compared with ICI alone, GKS with ICI may be associated with a reduced incidence of LMS. Further understanding of the mechanism, which remains unknown, may help improve the quality of life of patients with brain metastasis.

A effect of calcium hydroxide endodontic materials on the differentiation and the activation of osteoclast (수산화칼슘계 근관 충전제가 파골 세포의 분화 및 활성에 미치는 영향)

  • Jang, Eun-Young;Kown, Hoon;Lee, Chang-Hee;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.207-218
    • /
    • 2001
  • The purpose of this study was to investigate the direct inhibitory effect of calcium hydroxide materials on differentiation and activation of osteoclast. we used the osteoclast progenitor cells isolated from bone marrow cell of chick embryo tibia and four experimental materials [$Ca(OH)_2$ powder, Metapaste$^{(R)}$, Vitapex$^{(R)}$, Pulpdent$^{(R)}$] diluted at 0.1, 0.01, $0.05{\mu}g/ml$. There were measured both the number of differentiated osteoclast and the area of resorption lacunae. Also, we conducted MTT assay on U2OS osteoblast to examine of cytotoxic effect and obtained following result. 1. Considering the result of the inhibitory effects upon osteoclast differentiation, There were shown a significant difference increased in the following order: Metapaste$^{(R)}$, $Ca(OH)_2$ powder, Vitapex$^{(R)}$. But no significant difference was found in pulpdent group that the number of differentiated osteoclast was increased at all concentrations(p<0.05). 2. Among the three experimental groups, that is, $Ca(OH)_2$ powder, Metapaste$^{(R)}$, Vitapex$^{(R)}$ at $0.1{\mu}g/ml$ dilution that were statistically significant in reduction of the number of differentiated osteoclast. Vitapex group showed significant cytotoxic effect compared to control and another two groups exhibited no significant difference. Also, 0.2% DMSO group was shown statistically siginificant cytotoxicity (p<0.05). 3. Examining pattern and measured area of resorption lacunae in the control and the three experimental groups ,that is, $Ca(OH)_2$ powder, Metapaste$^{(R)}$, Vitapex$^{(R)}$ at $0.1{\mu}g/ml$ dilution, except $Ca(OH)_2$ powder group, statistically significant differences were found between experimental groups and control group. Also, DMSO group showed statistically significant decrease (p<0.05). From these results, we think that calcium hydroxide is responsible for suppression of hard tissue resorption by a direct inhibition of dfferentiation and activation of osteoclast.

  • PDF