• Title/Summary/Keyword: Orthopedics

Search Result 644, Processing Time 0.026 seconds

Comparison of Efficacy of New Bone Formation According to Implant Treatment in Xenograft Transplanted for Experimental Bone Defects of Rabbits (토끼 실험적 골 결손부에 이식한 이종 이식골편의 처리방법에 따른 신생골 형성능력 비교)

  • Song, Ha-Na;Lee, Jong-Il
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.350-357
    • /
    • 2007
  • Bone graft had been widely investigated for reconstruction of bone defects or acceleration of bone healing in orthopedics, neurosurgery and dental surgery. Autograft is the golden standard of bone graft but it is associated with donor site morbidity and is restricted in quantity. Xenograft has been researched an alternative method for autograft. The purpose of this study was to investigate the efficacy of new bone formation according to three different preparations of implants on rabbit xenograft. Cortical bone xenografts which made from bovine femoral cortical bone were treated by freezing, freeze-drying or defat-freezing implant preparations. They were transplanted into proximal diaphyseal shaft of bifibulae of 15 rabbits which were divided into three groups according to their implant preparation method. The fibulae transplantations were evaluated radiographically and examined osteoblast activity by bone alkaline phosphatase (BALP) biweekly for 16 weeks to observe new bone formation and union of the experimental defected region. New bone formation was observed in 7 cases in freeze-drying and defat-freezing group, respectively. Union of proximal and distal end of defected region, which was considered as success of bone graft, was observed in 4 cases (40%; 4 of 10 cases), respectively. In freezing group, new bone formation was observed in 6 cases but, there is no union observed. BALP value was increased over twice after two weeks of graft procedure in all union cases of freeze-drying and defat-freezing group (two of five animals, respectively) then gradually decreased to 16th week. In non-union cases, there is no significant variation in BALP value. Defat-freezing or freeze-drying preparations of implants are more efficacious in new bone formation than freezing method on rabbit xenograft. While it is difficult to propose which is superior between defat-freezing and freeze-drying, defatting of implants may enhance new bone formation in xenograft.

Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy

  • Nepal, Manoj;Li, Liang;Bae, Tae Sung;Kim, Byung Il;Soh, Yunjo
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.563-569
    • /
    • 2014
  • Materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. This study was designed to evaluate bone response to titanium alloy containing Ti-32Nb-5Zr with nanostructure, anodic oxidation, heat treatment, and ibandronate coating. Rats were randomly assigned to two groups for implantation of titanium alloy (untreated) as the control group and titanium alloy group coated with ibandronate as the experimental group. Then, the implants were inserted in both tibiae of the rats for four weeks. After implantation, bone implant interface, trabecular microstructure, mechanical fixation was evaluated by histology, micro-computed tomography (${\mu}CT$) and the push-out test, respectively. We found that the anodized, heat-treated and ibandronate-coated titanium alloy triggered pronounced bone implant integration and early bone formation. Ibandronate-coated implants showed elevated values for removal torque and a higher level of BV/TV, trabecular thickness and separation upon analysis with ${\mu}CT$ and mechanical testing. Similarly, higher bone contact and a larger percentage bone area were observed via histology compared to untreated alloy. Furthermore, well coating of ibandronate with alloy was observed by vitro releasing experiment. Our study provided evidences that the coating of bisphosphonate onto the anodized and heat-treated nanostructure of titanium alloy had a positive effect on implant fixation.

Comparison of Muscle Activations on Knee Joint Forms and Walker Types in Cerebral Palsy of Spastic Diplegia (경직성 양쪽다리 뇌성마비의 무릎관절 형태와 보행기 종류에 따른 근활성도 비교)

  • Ahn, So-Youn
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.339-348
    • /
    • 2012
  • Purpose : The purpose of this study is to compare muscle activations of neck, trunk and leg in cerebral palsy of spastic diplegia with genu recurvatum and knee flexion contracture, when using anterior and posterior walkers. Methods : We selected 21 cerebral palsy and received the written consent to participate in this study. The inclusion criteria for participation required patients to have spastic diplegic CP; to be between 3~6 years of age, to have a GMFCS III grade, to have no botulinum toxin injection and orthopedics surgery within before six months starting the study. Measurements of muscle activities (sternocleidomastoid, splenius capitis, rectus abdominis, erector spinea, gluteus maximus, rectus femoris, medial hamstring and calf muscles) were evaluated anterior and posterior walker ambulations. Statistical evaluation of these data were accomplished by utilizing the paired t-test and independent t-test by SPSS 20.0 program. Significance level was set at p<.05. Results : The following results were obtained. There was significant difference on muscle activation of neck, trunk and legs(soleus except) in anterior and posterior walkers. There was no significant difference in muscle activation of neck but significant difference in muscle activation of trunk, legs between genu recurvatum and knee flexion contracture(rectus abdominis, medial hamstring when using anterior walker, rectus abdominis, erector spinea, gluteus maximus, medial hamstring when using posterior walker). Conclusion : The conclusion of this study is the different knee joint forms would have different effect on muscle activation of trunk and legs while cerebral palsy of spastic diplegic ambulated with anterior walker and posterior walker.

Radiologic Outcome of Beta-Tricalcium Phosphate as a Bone Substitute in Orthopaedic Surgery (정형외과 수술에서 골대체제로써 Beta-Tricalcium Phosphate 사용에 대한 방사선학적 결과)

  • Park, Hyungseok;Moon, Jeong Eun;Cho, Yong Jin
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.4
    • /
    • pp.133-144
    • /
    • 2019
  • Objectives: To analyze the radiologic results of patients treated with bone defects treated with beta-tricalcium phostphate (β-TCP) in orthopedic surgery. Methods: Medical records of 49 patients, consisting of 24 (49.0%) men and 25 (51.0%) women were retrospectively reviewed. Graft incorporation was evaluated based on Irwin's radiologic staging. Results: The explanatory power of the total regression equation in Irwin's stage at 3 months postoperatively according to three explanatory variables, namely graft tightness, age at diagnosis, and lesion volume, was 65.6%; the explanatory power of Irwin's stage at 6 months postoperatively according to two variables, namely lesion volume and graft tightness, was 32.9%; and the explanatory power of Irwin's stage at 9 months postoperatively for two variables, namely longitudinal lesion length and graft tightness in the total regression, was 30.8%. Conclusions: Graft tightness, lesion volume, age at diagnosis, and longitudinal lesion length are the common factors affecting graft incorporation.

T1 Slope and Cervical Sagittal Alignment on Cervical CT Radiographs of Asymptomatic Persons

  • Park, Ji Hoon;Cho, Chul Bum;Song, Jun Ho;Kim, Seok Woo;Ha, Yoon;Oh, Jae Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.356-369
    • /
    • 2013
  • Objective : We performed a retrospective analysis of medical records and radiographic images of patients who never underwent spinal treatment including diagnosis. The objective of this study is to explain the biomechanical and physiologic characteristics of cervical alignment related to thoracic inlet angle including T1 slope changes in each individual. Methods : We reviewed the cervical CT radiographs of 80 patients who visited ENT outpatient clinic without any symptom, diagnosis and treatment of cervical spine from January 2011 to September 2012. All targeted people were randomized without any prejudice. We assessed the data-T1 slope, Cobb's angle C2-7, neck tilt, sagittal vertical axis (SVA) C2-7 and thoracic inlet angle by the CT radiographs. Results : The relationships between each value were analyzed and we concluded that Cobb's angle C2-7 gets higher as the T1 slope gets higher, while the SVA C2-7 value decreases. Conclusion : We propose that the T1 slope is background information in deciding how much angle can be made in the cervical spinal angle of surgical lordotic curvature, especially severe cervical deformity.

Analysis of the Current State of Home Health Nursing for Elderly Patients in Advanced General Hospital (일 상급종합병원 노인 환자의 가정간호 서비스 이용 현황 분석)

  • Park, Sung Hye;Jang, Yeon Soo;Kim, Su Jin
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.3
    • /
    • pp.275-284
    • /
    • 2019
  • Purpose: The purpose of this study was to analyze the current state of home health nursing (HHN) for elders and to provide basic data on policy alternatives for establishing home medical care in the advanced general hospital. Methods: This study was conducted as a secondary data analysis, using electronic medical record (EMR) data of older patients who received HHN more than once from the S advanced general hospital between January 2016 and December 2018. Results: A total of 1,790 patients received HHN visits, with 22,477 visits being made. The mean age was 76.8±7.3 years old, 96.0% of elders had health insurance and 24.6% had orthopedics problems. Of the 1,168 people who visited emergency rooms, the most frequent symptom was pain (23.4%) and all patients visited the hospital at least once and at most 163 times outpatient care during HHN. Causative diseases were degenerative knee joint osteoarthritis (0.6%), surgery for right knee replacement (4.0%), and for dressings (9.7%) in the HHN service content analysis. Conclusion: The progress towards an aging society and the introduction of community care are expected to further enhance the need for HHN which should be able to provide comprehensive and continuous visiting health care services to the older patients. The results of this study are expected to help doctors solve problems not solved by HHN, reduce unnecessary emergency room or outpatient visits, and readmission, while at the same time contributing to the improvement of patient quality of life through efficient patient health care.

Langerhans Cell Histiocytosis with Central Diabetes Insipidus : A Case Report (중추성 요붕증이 동반된 랑게르한스 세포 조직구증 1예)

  • Kim, Jin-Ho;Moon, Jun-Sung;Mun, Sun-Jung;Lee, Ji-Eun;Choi, Jae-Won;Eun, Mi-Jung;Chun, Kyung-A;Cho, Ihn-Ho;Yoon, Ji-Sung;Won, Kyu-Chang;Lee, Kyung-Hee;Shin, Duk-Seop;Lee, Hyoung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2005
  • Central diabetes insipidus (DI) is a syndrome characterized by thirst, polydipsia and polyuria. Langerhans cell histiocytosis is one of the etiologies of DI. Recently we experienced a central DI associated with Langerhans cell histiocytosis. The 44 years old female patient complained right hip pain, polydipsia and polyuria. We carried out water deprivation test. After vasopressin injection, urine osmotic pressure was increased from 109 mOsmol/kg to 327 mOsmol/kg (300%). Brain MRI showed a thickened pituitary stalk and air bubble like lesions sized with 5cm, 7cm was shown on fifth L-spine and right hip bone at hip bone CT. CT guided biopsy revealed abnormal histiocytes proliferation and abundant lymphocytes. The final diagnosis was central DI associated with systemic Langerhans cell histiocytosis invading hip bone, L-spine and pituitary stalk. Desmopressin and etoposide chemotherapy were performed to the patient.

  • PDF

Long non-coding RNA T-cell leukemia/lymphoma 6 serves as a sponge for miR-21 modulating the cell proliferation of retinoblastoma through PTEN

  • Tao, Sisi;Wang, Weidong;Liu, Pengfei;Wang, Hua;Chen, Weirong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.6
    • /
    • pp.449-458
    • /
    • 2019
  • Retinoblastoma (Rb) is one of the most common eye malignancies occur in childhood. The crucial roles of non-coding RNAs, particularly long non-coding RNAs (lncRNAs) and microRNAs (miRNAs), have been widely reported in Rb progression. In the present study, we found the expression of lncRNA T-cell leukemia/lymphoma 6 (TCL6) was significantly downregulated in Rb tissues and cell lines. Knockdown of lncRNA TCL6 promoted cell proliferation while reduced cell apoptosis in Rb cells. Moreover, lncRNA TCL6 serves as a sponge for miR-21, a previously-reported oncogenic miRNA in Rb, by direct targeting to negatively regulated miR-21 expression, therefore modulating Rb proliferation through miR-21. TCL6 overexpression inhibited Rb cell proliferation while miR-21 overexpression exerted an opposing effect; the effect of TCL6 overexpression was partially attenuated by miR-21 overexpression. PTEN/PI3K/AKT signaling pathway was involved in lncRNA TCL6/miR-21 axis modulating Rb cell proliferation. Taken together, lncRNA TCL6 serves as a tumor suppressor by acting as a sponge for miR-21 to counteract miR-21-mediated PTEN repression.

Analysis of Walking Using Smartphone Application (스마트폰 어플리케이션을 이용한 보행 평가)

  • Jung, Sangcheol;Lee, Inyoung;Yoon, Soobin;Kim, Suyeon;Woo, Youngkeun
    • PNF and Movement
    • /
    • v.13 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • Purpose: The accelerometer is a tool for evaluating walking by the displacement of the center of mass (COM) in the body. Recently, smartphones have added an accelerometer app, and it can be used to evaluate outcomemanures in rehabilitation. The purpose of this study was to investigate the COM in the bodies of normal persons and stroke patients using this smartphone application while walking. Methods: Twenty normal persons and twenty-two stroke patients were recruited and had their COM measured using G-walk and the smartphone application, SMAP, during 10 m walking. Subjects repeated the 10 m of walking 3 times, and we used the SMAP, Accelerometer Monitor ver. 1.5.0, to evaluate COM during the walk. To measure the displacement of COM, we used the difference in value between the maximal angle and the minimum anterior-posterior (AP), mediolateral (ML), and rotational angles during the walk. Results: For the normal persons, there was significant correlation between the AP and AP of SMAP, and was also a significant correlation between rotational angle and the ML of SMAP. In the stroke patients, there was significant correlation between AP and ML, and the rotational angle of SMAP. Conclusion: Our research results suggest that if the SMAP system is reinforced in the case of patients who have a greater displacement of COM, it may be used as an evaluation tool during walking.

Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System (TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.52 no.3
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.