• Title/Summary/Keyword: Organic wastewater

Search Result 1,238, Processing Time 0.023 seconds

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

1,3-Propanediol Fermentation using the by-Products from Fat Industry (글리세롤을 함유한 유지산업 부산물의 1,3-propanediol 발효)

  • 김철호;김승환;김세정;박건규;이상기
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.255-260
    • /
    • 2002
  • 1,3-Propanediol as a bifunctional organic compound could be used in polymerization reactions producing polyesters and polyurethanes. Byproduct containing high concentration of glycerol from fat industry was used to produce 1,3-propanediol in lower production cost as well as waste treatment. In this study, various attempts were made to increase 1,3-propanediol production under different conditions using Klebsiella pneumoniae ATCC 15380. The conversion yield and byproduct formation were influenced significantly by the fermentation pH and temperature. The optimal glycerol and nitrogen concentration for 1,3-propanediol production were found to be 25 a/L and 1%(w/v), respectively. The formation of 1,3-propanediol was optimal at pH 6.0 and temperature $35^{\circ}C$. 1,3-Propanediol production from byproduct from 2.5% glycerol was lower than that of 2.5% commercial glycerol and amounted only to 9.84 a/L from byproduct, while to 12.13 a/L from commercial glycerol.

Treatment Characteristics of Trichloroethylene(TCE) by Oxidation and Reduction with Nanoscale Zero-valent Iron (나노영가철의 산화·환원에 의한 트리클로로에틸렌 처리특성)

  • Park, Young-Bae;Jung, Yong-Jun;Choi, Jeong-Hak;Moon, Boung-Hyun
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.903-910
    • /
    • 2014
  • This study examined the treatment characteristics of hard-to-degrade pollutants such as TCE which are found in organic solvent and cleaning wastewater by nZVI that have excellent oxidation and reduction characteristics. In addition, this study tried to find out the degradation characteristics of TCE by Fenton-like process, in which $H_2O_2$ is dosed additionally. In this study, different ratios of nZVI and $H_2O_2$, such as 1.0 mM : 0.5 mM, 1.0 mM : 1.0 mM, and 1.0 mM : 2.0 mM were used. When 1.0 mM of nZVI was dosed with 1.0 mM of $H_2O_2$, the removal efficiency of TOC was the highest and the first order rate constant was also the highest. When 1mM of nZVI was dosed with 0.5 mM of $H_2O_2$, the first order rate constant and removal efficiency were the lowest. The size of first order rate constant and removal efficiency was in the order of nZVI 1.0 mM : $H_2O_2$ 1.0 mM > nZVI 1.0 mM : $H_2O_2$ 2.0 mM > nZVI 1.0 mM : $H_2O_2$ 0.5 mM > $H_2O_2$ 1.0 mM > nZVI 1.0 mM. It is estimated that when 1.0 mM of nZVI is dosed with 1.0 mM of $H_2O_2$, $Fe^{2+}$ ion generated by nZVI and $H_2O_2$ react in the stoichiometric molar ratio of 1:1, thus the first order rate constant and removal efficiency are the highest. And when 1.0 mM of nZVI is dosed with 2.0 mM of $H_2O_2$, excessive $H_2O_2$ work as a scavenger of OH radicals and excessive $H_2O_2$ reduce $Fe^{3+}$ into $Fe^{2+}$. As for the removal efficiency of TOC in TCE by simultaneous dose and sequential dose of nZVI and $H_2O_2$, sequential dose showed higher first order reaction rate and removal efficiency than simultaneous dose. It is estimated that when nZVI is dosed 30 minutes in advance, pre-treatment occurs and nanoscale $Fe^0$ is oxidized to $Fe^{2+}$ and TCE is pre-reduced and becomes easier to degrade. When $H_2O_2$ is dosed at this time, OH radicals are generated and degrade TCE actively.

Long-term Performance of Secondary dam Installed for Water Purification of Reservoir (호소의 수질개선을 위하여 설치한 부댐의 장기간 성능평가)

  • Kim, Bong-Kyun;Park, Jun-Seok;Won, Hee-Jae;Kim, Yun-Yung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.668-676
    • /
    • 2018
  • Most reservoirs in Korea have a low water depth and are small in size. Water pollution of the reservoir is serious because of the organic matter flowing from livestock wastewater, domestic sewage, and farmland. In this study, an attempt was made to improve the water purification effect by replacing the secondary dam installed in the depression area of the agricultural reservoir with the riprap dam. To evaluate the long-term performance, a riprap dam was installed in a reservoir in Gyeonggi province and water purification effect for 36 months was measured. The field test results showed that COD was 14.6%, SS 38.6%, T-N 9.5%, and T-P 11.2%. The concentrations in the influent water exhibited a significant change according to season, and the water purification effect increased with increasing concentration of influent water. The pollutant flowing into the lake from the depression area can be blocked effectively if the secondary riprap dam for water purification is installed in the agricultural reservoir.

A Study on the Odor Characteristics and Identification of Microbial in Biological Swine Manure Treatment Process by Bioreactor (생물반응기를 도입한 돈분뇨의 생물학적 처리공정에서 악취발생 특성 및 미생물동정에 관한 연구)

  • Ko, Joon-il;Park, Gui-hwan;Bae, Ju-soon;Oh, Gil-young;Chung, Seon-yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.526-532
    • /
    • 2015
  • A bioreactor filling with pellets and stones was equipped to the swine manure treatment system, which is expected to emit high concentration of odor in the process of the organic wastewater treatment system, and in comparison with the activated sludge process as the control process, the reactor operation state, treatment water quality and odor emission concentration were measured. The reactor using the bioreactor proved to be much more stable in the bubble condition, treatment water transparency, etc, and BOD removal efficiency was also much better. The removal efficiency of T-N and T-P, however, showed little difference in the two reactors. Odor, as a result of examining $NH_3-N$, $NH_3$ concentratio, and complex odor, was 4 times to 24 times less emitted in the system using bioreactor than in the activated sludge system. $H_2S$, methyl mercaptan, dimethyl sulfide, and dimethyl disulfide were not found or were found in only 5 ppbs in each reactor and showed little difference between the two reactors. In the bioreactor process, Bacillus sp./ Pseudomonas sp. species were mainly found and in the activated sludge process, acterium sp. Chryseobacterium sp. species were mainly found.

Analysis on Trends and Major Impact Factors of Water Quality Dynamics in the Gab-Cheon River, Daejeon, Korea (대전 갑천의 수질변화 경향 및 주요 수질 영향 인자 분석)

  • Lee, Gayoung;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.517-525
    • /
    • 2015
  • This study analyzes water quality change trends in three major rivers in Daejeon and effect of discharge from Daejeon Wastewater Treatment Plant between 1992 and 2014. As of 2014, COD concentration in the Gab-cheon-A station is in level VI for Korea river water quality standard while BOD and TP are in level III. As expansions of the treatment plant, water quality in the Gab-cheon River has been improving accordingly. However, during the study period, TN concentrations of the headwater and the most downstream locations of the Gab-cheon River have increased about twice and three times, respectively. It was estimated that the treatment plant is responsible for 35%. 46%, 76% and 63% of BOD, COD, TN and TP loadings of the Gab-cheon River, respectively. It was also estimated that small tributaries and nonpoint sources are responsible for 54% and 47% of BOD and COD loadings of the Gab-cheon River. Therefore, it is recommended to further reduce nutrient loadings from the treatment plant and also reduce surface runoff organic loading from nonpoint sources including small tributaries and storm sewers.

Slurry Phase Decomposition of Food Waste by Using Various Microorganisms (미생물을 이용한 액상소멸방식의 음식물쓰레기 처리)

  • Kwon, Bum Gun;Na, Suk-Hyun;Lim, Hye-Jung;Lim, Chae-Sung;Chung, Seon-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.303-310
    • /
    • 2014
  • This study investigated the reduction of food waste through the slurry phase decomposition in a source of food waste by microorganisms. The reactor used in the experiment was composed of both woodchip with wood material and sponges with polyurethane material as media of attached microorganisms, and food waste was mixed with a constant cycle consisted of a stirring device. During the experimental period of 100 days, the change in weight over the cumulative total amount of food waste added was reduced by 99%. Approximately, 1% of the residual food waste could be inherently recalcitrant materials (cellulose, hemicellulose, lignin, etc.) and thus was thought to be the result of the accumulation. The initial pH in wastewater generated from food waste was low with 3.3 and after 24 hours treatment this pH was increased to 5.8. The concentrations of COD, BOD, SS, salinity, TN and TP were gradually decreased. Food waste decay was proceeded by the seven species microorganisms identified and confirmed in this study, making a slurry phase and thus reducing residual food wastes. In the initial phase, the microbial population was approximately $3.3{\times}10^4$ cell/mL, and after 15 days this population was a constant with $5.1{\times}10^6$ cell/mL which means a certain stabilization for the reduction of food wastes. From these results, it can be considered that organic matter decomposition as well as the weight loss of food wastes by microorganisms is done at the same time.

Analysis of adsorption behavior of lead ion on to surface modified AlPO4 materials (표면처리된 AlPO4에 대한 납 이온의 흡착 거동 분석)

  • Kim, Young-Ho;Kil, Hyun-Suk;Kang, Kwang-Cheol;Choi, Suk-Nam;Rhee, Seog-Woo
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.275-281
    • /
    • 2011
  • $AlPO_4$-type material was synthesized by a reaction of $Al(OH)_3$ and H3PO4 with organic templates from wastewater of detergent manufacturer. The surface of material was coated with carboxylate groups by the reaction of succinic anhydride with surface amino groups which were formed by treatment of the material with APTMS. Powder XRD patterns showed the characteristic patterns of $AlPO_4$. Morphology of the material was examined using a SEM and the functional groups were investigated by FT-IR analysis. The surface charge of a aqueous suspension was analyzed: $AlPO_4-NH_2$ has positively charged surface while $AlPO_4$-COOH has negatively charged one. They were used for the removal of toxic metals from aqueous solution. The lead ions were adsorbed on the surface by the formation of complexes with carboxylate of surface and $K_d$ was 91.1 mL/g. In conclusion, the $AlPO_4$-COOH might be applicable in the removal of toxic metal ions from aqueous system.

A Study on Characteristics of Aerobic Liquid-Composting using a Micro Air Diffusion and a Mixer System (미세기포와 교반을 이용한 호기성 액비특성에 관한 연구)

  • Gu, Bon-Woo;Oh, Dae-Min;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1354-1360
    • /
    • 2010
  • The purpose of this study is to analyze the behavior of swine slurry wastewater from bogen, in the treatment of Aerobic Liquid-Composting treatment by Aerobic Liquid-Composting using a mixer and Micro Air Diffusion pH level was at the beginning and its rise was seemingly related to VFA. It appears that removal of BOD and COD are more effective by Aerobic than by Anaerobic. In terms of removal efficiency, it shows 70.9% of BOD and 39% of COD in M.A+Mix and 67.8% of BOD and 19% of COD in M.A. $NH_3-N$ decreases in all conditions, which is caused by both the characteristic of nitrogen and the rise of pH. $NO_3-N$ increases in all conditions. It is judged that the accumulation of $NO_3-N$ affects the reduction of the ratio of denitrification. In the result of the analysis of Manure in swine slurry of liquified fertilizer ingredients, content of Manure in swine slurry of liquified fertilizer ingredients in aerobic conditions (M.A+Mix) is higher than anaerobic conditions.

Application of RO Membrane Process for Reuse of MBR Effluent (MBR 유출수 재활용을 위한 RO 막분리 공정에 대한 연구)

  • Yoon, Hyun-Soo;Kim, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1391-1398
    • /
    • 2010
  • Reuse feasibility of MBR effluent of S Electronic Company's organic wastewater as a LCD process water was investigated by a $32m^3/d$ pilot-scale RO membrane process. The effects of operating pressure and permeate flux at constant 85% recovery of RO membrane process using MBR effluent were analyzed for transmembrane pressure and period for CIP by membrane fouling as well as rejection of TOC and conductivity. MBR effluent requires additional treatment to meet the LCD process water quality criteria of TOC<1 mg/L and conductivity<$100{\mu}S/cm$ which is stringent as compared with those of conventional reuse water quality criteria. The RO process operated at 85% recovery with stepwise increasing of permeate fluxes from 12.5 LMH to 22.0 LMH was able to meet LCD process water quality criteria. However, the transmembrane pressure increased and the period of CIP decreased as increasing permeability fluxes due to fouling of RO membrane. The optimum operational conditions of RO membrane process were permeate fluxes of 16.5~18.5 LMH with operating pressure of $6.7{\sim}12.4kgf/cm^2$ and CIP period of 20~25 days at constant 85% recovery.