• 제목/요약/키워드: Organic pretreatment

검색결과 295건 처리시간 0.025초

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

해수담수화 전처리 기술과 향후 도전 (Seawater Desalination Pretreatments and Future Challenges)

  • 장호석;권대은;김정환
    • 멤브레인
    • /
    • 제25권4호
    • /
    • pp.301-309
    • /
    • 2015
  • 최근 해수담수화 기술에 관한 관심이 증가하면서 해수 전처리 기술의 중요성이 날로 증가하고 있다. 해수담수화 기술은 미래 수처리 핵심기술로 자리매김하고 있고 이를 위한 전처리 기술의 올바른 선택과 운영은 향후 해수담수화 기술의 효율향상과 공정 최적화를 위해 중요하게 고려되어야 할 것이다. 해수담수화 전처리 기술의 목적은 주로 해수에 존재하는 입자성 물질, 콜로이드성 물질, 유기물질, 무기물질 그리고 미생물 오염물질 등의 처리를 통해 후단 담수화 기술의 효율성을 향상시키기 위함이나 전처리 기술 대상 처리물질의 범위는 매우 다양하여 맞춤형 전처리 기술의 적절한 적용이 필요하다. 해수담수화에서 올바른 전처리 기술의 적용은 후단 담수화 시설의 높은 처리효율 및 문제점을 최소화시킴과 동시에 해수의 큰 수질변동과 기후적인 그리고 지역적인 영향 등에 즉각적으로 대처할 수 있으므로 전처리 기술의 운영전략은 미래 해수담수화 기술의 성공여부를 결정짓기 위해 매우 중요하게 다루어져야 한다. 또한 최근에 많은 관심을 가지고 있는 해수 미세조류의 번성은 담수화 전처리 기술의 선정에 있어서 잠재적인 장애가 되고 있어 이에 대한 올바른 이해도 반드시 필요하다. 본 총설에서는 해수담수화 전처리 기술에 관한 그동안의 연구동향을 분석하고 해수담수화 전처리 기술의 선택 및 운전 최적화 달성을 위한 향후 도전과제들을 제시하고자 한다.

Anaerobic digestate as a nutrient medium for the growth of the green microalga Neochloris oleoabundans

  • Abu Hajar, Husam A.;Guy Riefler, R.;Stuart, Ben J.
    • Environmental Engineering Research
    • /
    • 제21권3호
    • /
    • pp.265-275
    • /
    • 2016
  • In this study, the microalga Neochloris oleoabundans was cultivated in a sustainable manner using diluted anaerobic digestate to produce biomass as a potential biofuel feedstock. Prior to microalgae cultivation, the anaerobic digestate was characterized and several pretreatment methods including hydrogen peroxide treatment, filtration, and supernatant extraction were investigated and their impact on the removal of suspended solids as well as other organic and inorganic matter was evaluated. It was found that the supernatant extraction was the most convenient pretreatment method and was used afterwards to prepare the nutrient media for microalgae cultivation. A bench-scale experiment was conducted using multiple dilutions of the supernatant and filtered anaerobic digestate in 16 mm round glass vials. The results indicated that the highest growth of the microalga N. oleoabundans was achieved with a total nitrogen concentration of 100 mg N/L in the 2.29% diluted supernatant in comparison to the filtered digestate and other dilutions.

정밀여과법 하수재이용 공정에서 오존의 전처리 효과에 관한 연구 (Effect of Ozonation in Microfiltration Membrane for Wastewater Reuse)

  • 문성용;안세혁;이상협;박종훈;홍석원;최용수
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.535-543
    • /
    • 2006
  • The Ozone oxidation process was applied to increase the efficiency of reuse process when treating the secondary effluent by the membrane system. This paper focus on decreasing efficiency of membrane fouling, because of membrane fouling reduction by ozone and evaluation of application of the ozone oxidation. The feed water was secondary effluent from BNR process. The result shows that the ozone pretreatment can reduce membrane fouling effectively. Also, the improvement of treated water quality was obvious. The reduction of the membrane fouling led decrease of following pollutant and increase of lnner adsorptive ability of hydrophilic organic matter and decrease of molecular weight. MF membrane process alone can meet the domestic reuse water standards. And ozone pretreatment process also can increase the removal rates of turbidity, COD, nitrogen, and color.

NH2Cl 사용으로 인한 RO 막의 성능 향상 (Effect of Feed Monochloramination on Performance of RO Membranes)

  • 홍승관
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.312-317
    • /
    • 2005
  • The 15 month pilot study was performed to investigate the effect of pretreatment by monochloramine ($NH_2Cl$) on the performance of RO membranes made of cellulose acetate (CA) and polyamide (PA). Both RO membranes experienced severe biological fouling without any pretreatment during the treatment of highly organic surface water in Florida, USA. Feed monochloramination at 5 mg/L significantly minimized productivity loss by effective control of biofouling. The CA membrane did not show any structural damages by monochloramine, while the PA membrane suffered from a gradual loss of membrane integrity by chlorine oxidation, which was characterized as an increase in productivity and a decrease in selectivity. The degradation of PA membrane increased with increasing monochloramine dose.

이온성 액체/DMF 혼합용매 전처리 후 기계적 해섬을 통한 리그노셀룰로오스 나노섬유의 제조 (Preparation of Lignocellulose Nanofiber by Mechanical Defibrillation After Pretreatment Using Cosolvent of Ionic Liquid and DMF)

  • 한송이;박찬우;이승환
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권3호
    • /
    • pp.268-277
    • /
    • 2017
  • 본 연구는 리그노셀룰로오스의 주성분 용해에 우수하다고 알려진 이온성 액체인 1-ethyl-3-methylimidazolium acetate ([EMIM]Ac)와 셀룰로오스와 친화성이 있는 유기용매인 dimethylformamide (DMF)의 혼합용매를 이용하여 갯버들 목분을 처리한 후, 디스크밀 해섬에 의한 리그노셀룰로오스 나노섬유를 제조하고 그 특성을 평가하였다. 무처리샘플과 DMF 및 [EMIM]Ac가 10과 30% 포함된 혼합용매로 목분의 고형분량을 15%로 선정하였다. 전처리물의 X선 회절도로부터 모든 샘플이 셀룰로오스 I의 패턴을 나타냈으며, 상대결정화도는 [EMIM]Ac가 30% 포함된 혼합용매로 2시간 처리한 전처리물이 가장 낮았다. 무처리 및 DMF와 [EMIM]Ac가 10% 포함된 혼합용매로 처리한 전처리물의 평균결정크기는 약 3.2 nm였으며, [EMIM]Ac가 30%까지 포함되고 처리 시간이 경과할수록 다소 감소하는 경향을 나타내었다. 혼합용매의 사용을 통한 전처리물의 목재세포벽 구조의 완화로 해섬 효율이 향상되었으며, 전처리 시간 및 해섬 시간이 경과할수록 비표면적이 증가하는 경향을 나타내었다.

동결 전처리가 매실의 착즙과 건조 특성에 미치는 영향 (Effects of Freezing Pretreatment on Juice Expression and Drying Characteristics of Prunus mume Fruit)

  • 정헌식;김한수;이영근;성종환
    • 한국식품저장유통학회지
    • /
    • 제17권4호
    • /
    • pp.507-512
    • /
    • 2010
  • 매실(Prunus mume)의 착즙과 건조 특성에 동결 전처리가 미치는 영향을 조사하기 위하여, 매실을 동결처리($-20^{\circ}C$)하거나 처리하지 않고 착즙수율과 주스의 품질특성 및 건조속도와 분말의 품질특성을 각각 측정하였다. 매실의 착즙수율과 건조속도는 동결처리구가 무처리구보다 유의적으로 높은 수준을 나타내었다. 압착주스와 건조분말의 L과 b값 및 a값은 동결처리구가 무처리구보다 유의적으로 낮고 높은 수준을 각각 보였다. 압착주스와 건조분말의 유리당과 유기산 함량은 동결 전처리에 따른 유의적인 차이를 나타나지 않았다. 주스의 가용성 고형분 함량, 적정산도 및 pH는 동결 전처리의 영향을 받지 않은 것으로 나타났다. 이로써 동결 전처리는 매실의 착즙과 건조 효율을 증대시킬 수 있는 유효한 방법이지만 착즙액과 건조분말의 갈변도가 높은 문제점이 있는 것으로 확인되었다.

십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명 (The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process)

  • 정철우;손희종
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.639-645
    • /
    • 2008
  • 십자형 응집-한외여과 막분리 공정 운전시 응집조건에 따른 영향을 살펴보면 급속교반-UF 공정과 응집-침전-UF 공정에서 투과 flux의 변화는 크게 나타나지 않았으며 UF막의 막오염 억제 측면에서는 응집전처리공정으로서 1분간의 짧은 급속혼화만으로도 충분한 것으로 나타났다. 교반강도에 따른 투과 flux의 변화결과 교반강도에 따라 형성되는 floc의 크기가 거의 유사하게 형성되어 교반강도에 따른 영향은 나타나지 않았다. 응집제 주입량에 따른 투과 flux변화를 살펴보면 응집제 주입량이 증가함에 따라 유기물의 제거가 크게 일어나 유기물 부하의 감소와 floc의 크기가 증가함에 따라 다공성 케이크층의 형성에 따른 막저항의 감소로 인하여 투과 flux가 향상되었다. 막의 재질과 전처리 응집공정적용에 따른 여과메카니즘 분석결과 막의 재질에 따라서는 친수성 재질의 막에 비하여 소수성 재질의 막의 경우 막의 공극속으로 입자의 침투가 발생하여 침적 흡착되는 현상과 막의 표면에서 형성되는 cake층에 의한 투과 flux 감소가 주원인이 되었으며 응집공정을 전처리공정으로 적용시 UF단독공정에 비하여 막오염 발생이 저감되었다.

제주도 삼양 수원지 RO 시설 도입 연구 (A Study on the Introduction of RO Facility for Jeju Samyang Water Source)

  • 김우찬;김진근
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.601-608
    • /
    • 2015
  • Pollutants removal efficiency in pretreatment(GAC filter, multi-media filter, disk filter) and RO facilities was investigated for the Jeju Samyang spring water source where raw water intake has been stopped due to sea water intrusion. In addition, preliminary feasibility analysis was conducted between RO and groundwater intake systems. Turbidity removal in 4 different pretreatment processes was less than 25% due to low concentration of turbidity(i.e., less than 0.21 NTU), while multi-media filter is recommended for the pretreatment facility based on the low organic content in raw water as well as cheaper operation and maintenance cost. The average concentration of $Cl^-$ in raw water was 691.4 mg/L, while that of RO permeate was 9.1 mg/L(i.e., removal efficiency was 98.4%). In addition, TDS removal efficiency was 98.1%, which was quite high. The production cost for RO system($Q=4,000m^3/d$) was $362.1won/m^3$ considering installation, operation and maintenance cost for 30 years. While that of groundwater was $262.6won/m^3$ which was low compared to the RO system. However, it is recommended to introduce RO system for Samyang water source rather than new groundwater development because Samyang water source has been discharged to the sea without any usage, while groundwater can be used for other purpose as a sustainable water source.