• Title/Summary/Keyword: Oral

Search Result 21,093, Processing Time 0.04 seconds

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep (수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과)

  • Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.110-115
    • /
    • 1999
  • Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

  • PDF

A Case of Rifampicin Induced Pseudomembranous Colitis (Rifampicin에 의한 위막성 대장염 1예)

  • Yun, Jong-Wook;Hwang, Jung-Hye;Ham, Hyoung-Suk;Lee, Han-Chul;Roh, Gil-Hwan;Kang, Soo-Jung;Suh, Gee-Young;Kim, Ho-Joong;Chung, Man-Pyo;Kwon, O-Jung;Rhee, Chong-H.;Son, Hee-Chung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.774-779
    • /
    • 2000
  • Pseudomembranous colitis, although uncommon, is an important complication of antibiotics that is related to a variety of deleterious effects on the gastrointestinal tract. Rifampicin is one of the 1st line agents in the treatment of tuberculosis and a large number of patients are exposed to its potential adverse effects. We report upon a patient that had diarrhea due to pseudomembranous colitis after receiving antitubeculous medication, and which was probably caused by rifampicin. A 77-year-old man was admitted with diarrhea of three weeks duration. One month previously, he suffered from left pleuritic chest pain and left pleural effusion was noticed at chest X-ray. One week prior to the onset of diarrhea, he was started on empirically isoniazid, rifampicin, ethambutol and pyrazynamide as antituberculous medication. On admission, he complained of diarrhea, left pleuritic chest pain, dyspnea and sputum. On physical examination, breathing sound was decreased in the left lower lung field and bowel sound increased. Pleural biopsy revealed chronic granulomatous inflammation, which was compatible with tuberculosis, Sigmoidoscopy showed whitish to yellowish pseudomembrane with intervening normal mucosa, and his stool was positive for C.difficle toxin. He was diagnosed as pseudomembranous colitis and treated with oral metronidazole and vancomycin. The diarrhea did not recur after reinstitution of the anti-tuberculous medication without rifampicin inpatients with severe diarrhea receiving anti-tuberculous medication, rifampicin induced pseudomembranous colitis should be excluded.

  • PDF

Comparison of chewing ability and quality of life before and after the dental implantation (임플란트 시술환자의 시술 전.후의 저작능력과 삶의 질 비교)

  • Kim, Kyeong-Won;Lee, Kyeong-Soo;Kang, Pock-Soo;Kim, Woo-Shik;Lee, Hee-Kyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • Statement of problem: Recently the populations of patients receiving implant surgery are greatly increase for maintaining oral health. Purpose: This study was conducted for implanted patients to assess the chewing ability patient satisfaction level and changes in quality of life before and after the implant surgery. Material and methods: The current study subjected 109 adult patients, older than 20 years of age, who received implant surgery from December, 2006 to October, 2007 at the 6 dental clinics located at Daegu and Ulsan metropolitan cities. Twice of surveys were conducted for the patients before and after receiving the dental implant surgery. Results: As the motivation of receiving implant surgery, 45.9% of the patients selected the surgery for the chance o "f chewing function recovery", and " failure of treatment and complications" was found to be the most worrisome at the time of surgery by recording 38.5%.The satisfaction level before the implant surgery scored 30.37, while the score was increased to 45.01 after the surgery by showing a significant difference before and after receiving the surgery(P<.001). Regard on the surgery, 91.8% of the patients responded as "Satisfy", and 89% of the study subjects responded that they have willingness to recommend the surgery to their families and friends. The chewing ability score measured by using the surveys on edible foods, the score before the surgery was 15.24, while the score was increased to 19.11 after the surgery by showing a significant difference before and after receiving the surgery(P<.001). The quality of life score was also found to be increased to 11.17 after the surgery from 9.99 before the surgery by showing a significant difference(P<.001). Conclusion: In a future, the studies on the numbers of implanted loss teeth and the location of tooth loss are necessary, more long-term follow study are needed, and it is thought to be necessary to enlarge the sample size of subjects in conducting the studies.

Evaluation of changes in adhesive strength and cytotoxicity of a denture adhesive according to time (시간에 따른 의치접착제의 인장 결합강도와 세포독성의 변화)

  • Jung, Ha-Yoon;Kim, Jee-Hwan;Lee, Keun-Woo;Shim, June-Sung;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.232-239
    • /
    • 2009
  • Statements of the problem: Many denture wearers occasionally use denture adhesives to improve denture retention, stability and chewing efficiency. An ideal denture adhesive is nontoxic, non-irritating, and provides comfort to the oral mucosa. Purpose: The purpose of this study was to evaluate the cytotoxicity and adhesive properties of a selected denture adhesive. Material and methods: To test cytotoxicity of the selected denture adhesive, mouse fibroblast cells were used in MTT testing. Cytotoxicity was examined according to the concentration of the denture adhesive and incubated for 1 to 4 days. To examine adhesive property, a denture base was fabricated on an edentulous dentiform. The adhesive was applied to the denture base, then tensile bond strength was measured, to evaluate the change in retention during 3 days. Results and Conclusion: 1. 1% and 2% concentration denture adhesive cream had no cytotoxicity. 2. The tensile bond strength of the group with both denture adhesive and artificial saliva was significantly higher than that of the group with only denture adhesive(P<.05). The tensile bond strength of the group with denture adhesive was significantly higher than that of with only artificial saliva(P<.05). 3. The tensile bond strength had no significant change during 1 hour, and then gradually decreased. After 1 day, it decrease to half. Within the limitation of this study, the tested denture adhesive had no cytotoxicilty and was effective in improving denture retention. The adhesive strength began to continuously decrease after 1 hour and it decreased to half at 1 day after application.

Evaluation of clinical status of fixed prosthesis (고정성 보철물의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • Statement of problem: Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complications of fixed prostheses were found in the mouth of patients. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. Purpose: The purpose of this study was to evaluate the clinical status of fixed prostheses. Material and methods: In order to assess the clinical status of fixed prostheses, a total of 161 individuals(aged 17-85, 99 women and 62 men with 1596 unit of fixed prostheses, and 1169 abutments) who first visited the Department of Prosthodontics, Pusan National University Hospital, between April to September, in 2007 were examined. Results and conclusion: The results of this study were as follows: 1. Length of service of fixed prostheses was $8.6{\pm}0.6$ years(mean), 10.0 years(median). 2. Location of fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in posterior region and in mandible where the failure rate was high in combination(P<.05). 3. Longevity of fixed prostheses made of metal was longest(mean: $13.0{\pm}9.3$, median: 14.0), gold, precious ceramic, non-precious ceramic trailing behind(P<.05). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in Single-unit and the failure rate was high in over 3-unit(P<.05). 5. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in natural dentition(P<.05). 6. Defective margin(28.2%), dental caries(23.0%), periodontal disease(19.3%), periapical disease(16.9%) were frequent complications. In 30.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva (인공타액에 노출되었던 금속도재관의 재소성이 색조와 표면기포 형성에 미치는 영향에 관한 연구)

  • Park, Ji-Hyun;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.161-167
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva. Materials and methods: Thirty disk-shaped specimens were made in 10 mm diameter with 0.5 mm metal core thickness and 1 mm ceramic thickness. A spectroradiometer was used to determine the CIE Lab coordinates. The number and size of surface bubble were observed with a stereomicroscope. After the exposure to artificial saliva for 7 days, re-firing was performed at glazing temperature. After re-firing, the CIE Lab were calculated, and the number and size of surface bubble were observed again. The change in shade was expressed with ${\Delta}E$. Statistical analysis was done with paired t-test for the change in the number of surface bubble and student t-test for the change in the size of surface bubble (${\alpha$}=0.05). Results: Shade difference was calculated 2.14 ${\Delta}E$ units. The mean number of surface bubble was $1.33{\pm}1.49$ before re-firing, $3.27{\pm}2.90$ after re-firing. After re-firing, the number of surface bubble was significantly increased (P<.05). The mean size of surface bubble was $81.97{\pm}32.03\;{\mu}m$ before re-firing, $142.94{\pm}47.40\;{\mu}m$ after re-firing. After re-firing, the size of surface bubble was significantly increased (P<.05). Conclusion: Shade change after re-firing was perceptible (${\Delta}E$ < 2.0) and clinically acceptable (${\Delta}E$ < 3.7). The number and size of surface bubble was significantly increased after re-firing. Further investigation to decrease the surface bubble on the extra oral repair of metal-ceramic crown, will be needed in future study.

EXPRESSION PATTERN OF RUNX2 IN MURINE TOOTH DEVELOPMENT (Mouse의 치아 발육시 Runx2의 발현 양상)

  • Kim, Tae-Wan;Ryoo, Hyun-Mo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.651-658
    • /
    • 2004
  • Runx2 is a transcription factor in homologous with Drosophila runt gene and it is essential for bone formation during embryogenesis and a critical gene for osteoblast differentiation and osteoblast function. Runx2-haploinsufficency causes cleidocranial dysplasia (CCD). CCD is an autosomal-dominant inherited disorder characterized by hypoplastic clevicle and delayed ossification in fontanelles and wormian bones. Dental defects are possibly shown to CCD patients : multiple supernumerary teeth, irregular and compressed permanent tooth crowns, hypoplastic and hypomineralized defects in enamel and dentin, an excess of epithelial root remnants, the absence of cellular cementum, and abnormally shaped roots. In addition, delayed eruption of the secondary dentition is a constant finding. The aim of this study is to evaluate the role of Runx2 in the tooth development and eruption through analyzing the expression pattern of Runx2 by in situ hybridization during crown (late bell stage) and root formation of tooth, using postnatal day 1, 4, 7, 14 and 21 mice mandibular molar teeth. mRNA of Runx2-full length is expressed in dental follicle and surrounding tissue at postnatal day1 and 4. At postnatal day 7, it is expressed in ameloblasts of occlusal surface of enamel and bone area surrounding the tooth. In comparison with previous stage, at postnatal day 14, it is expressed in ameloblasts of proximal surface of enamel. At postnatal day 21 it's expression is observed only in bone area. mRNA of Runx2-typeII is not expressed. At postnatal day 1 and 7. At postnatal day 14 and 21, it's expression is observed in the bone area. In this study, we suggest that Runx2 have a relation of ameloblasts differentiation and an important role to tooth eruption made by dental follicle during intraosseous eruption stage. Also we can confirm that Runx2 has a role to bone formation.

  • PDF

Complication and Failure Analysis of Fixed Restorations (고정성 보철물과 연관된 합병증과 실패에 관한 조사)

  • Yun, Mi-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complication of fixed prostheses was found in the mouth of patient. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 154 individuals (aged 22-82, 88 women and 66 men loaded with 578 unit of fixed prostheses, and 423 abutments) who visited the Department of Prosthodontics, Pusan National University Hospital, between January 2009 to December 2009 and removed old fixed prostheses were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $10.3{\pm}05.5$ years (mean), 10.0 years (median). 2. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was high in anterior-posterior combination region (mean:13.1, median:13.5) than anterior and posterior region. 3. Longevity of fixed prostheses made of metal was longest (mean:13.3, median:12.3). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 5. Condition of opposing dentition was found to have statistically significant influence on longevity of fixed prostheses (P>.05). The fixed prostheses lasted longest when opposed by complete denture (mean:17.1, median:19.7), removable partial denture, fixed prosthesis and natural dentition trailing behind (P<.05) 6. Periodontal disease (37.5%), dental caries (19.0%), defective margin (18.4%) were frequent complications. In 33.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.