• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.021 seconds

Minimal Illumination to Identify the Chart in Each Visual Acuity and Deviation of Identification Capability According to Illumination and Chart Contrast (시력 단계별 시표 식별 최소조도 및 대비도와 조도에 따른 시표 식별능력의 차이)

  • Kim, Sang-Yeob;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.549-554
    • /
    • 2013
  • Purpose: To determine the minimal illumination for visual acuity with the decimal vision chart and individual difference with varying contrast and illumination. Methods: Landolt's vision chart with 10 different grade of contrast was made. Minimal illumination was measured for 69 eyes using 100% contrast vision chart. Minimal contrast for identifying the chart was measured in conditions of the minimal illumination and 230 lx, respectively. Results: Minimal illumination was gradually increased with decrease of the chart size. Mean of minimal illumination to identify the 1.0 visual acuity was $74.39{\pm}25.90$ lx with range of 17~107 lx. In conditions of the minimal illumination and 230 lx, the minimal contrast for identifying the chart were gradually increased with decrease of the chart size in both conditions, the those deviation for 69 eyes was also increased. Conclusions: For refractive correction, examiners need to consider the individual difference for identifying the visual chart according to illumination and contrast.

A Study on the Ametropia in Asian Population (아시아 동양인들의 비정시에 관한 연구)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2008
  • Purpose: This study was to investigate the refractive state of an asian population (male: 39, female: 53) from 21 to 30 years old who visited the A optical shop at jongnogu in seoul. Methods: The visual acuity test was performed by the object and subject method. Results: Among the 184 eyes, myopia is 83.16% and emmetropia is 16.84%, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -m0.5Dt < spheric equivalent ${\leq}$ -2.00Dt was 40.53%, the -2.00Dt < spheric equivalent ${\leq}$ -6.00Dt was 51.63% and anything over the -6.00Dt was 7.85%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 46.67%, 35.56% and 7.77%, respectively. The average of pupillary distance in male (64.5${\pm}$2.9 mm) was greater than that in female (61.9${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription by this research.

  • PDF

Development of Hydrogel for Decrease Protein Adsorption and Application to Intraocular Lens (단백질흡착 감소용 하이드로겔의 개발 및 인공수정체로의 적용)

  • Ko, Na Young;Lee, Hyun Mee
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.1
    • /
    • pp.30-35
    • /
    • 2018
  • The purpose of this study was to decrease the protein adsorption and improve the function of the hydrophobic acrylic Intraocular lens(IOL). Hydrophobic acrylic intraocular lenses were prepared by using ethyleneglycol phenyletheracrylate (EGPEA), styrene and 2-hydroxyethyl methacrylate (HEMA). Polyvinyl pyrrolidone (PVP) and 2-methacryloyloxyethyl phosphorylcholine (MPC) were used as additives. Water contents, wettability, light transmittance and protein adsorption amount were measured to evaluate the physical properties of the intraocular lens. The water content and wettability of all samples containing additives were increased and the amount of protein adsorption decreased. In particular, samples containing MPC showed a further decrease in protein adsorption. The hydrophobic acrylic intraocular lens with PVP and MPC was found to improve the function of the intraocular lens by reducing the protein adsorption while having basic physical properties.

Improvement effect of Functional Myopia by Using of Vision Training Device(OTUS) (Vision Training Device(OTUS)적용에 따른 기능성 근시의 개선 효과)

  • Park, Sung-Yong;Yoon, Yeong-Dae;Kim, Deok-Hun;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.147-154
    • /
    • 2020
  • This study is about the development of ICT-based wearable devices for vision recovery that can cause functional myopia improvement through accommodation training. Vision Training Device(OTUS) is a head mount type wearable device, which naturally stimulates the contraction and relaxation of the ciliary muscles of eye. Users can conduct customized vision training based on personal vision information stored through the device. In the experiment, the effects of improvement of the symptoms by the accommodation training were compared and analysed for the two groups (16 comparative group and 16 accommodation training group) after causing functional myopia. The result showed the functional myopia improved average 0.44D±0.35 (p<0.05) at the accommodation training group compared to the comparative group. This study proved the effectiveness of vision training device(OTUS) on functional myopia, but further clinical trials are judged necessary to prove the possibility of long-term control of the functional myopia.

Study on Brand Naming of Optical Shop through Creation of Alternative (대안의 창출을 통한 안경원 브랜드 네이밍 연구)

  • Hong, Sung-Il;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • Purpose: This study aims to understand effective brand naming process of an optical shop brand by a research of brand naming process of optical shop through creation of alternative. Methods: It investigated brand naming process such as character abstraction, target grasp, naming direction set, naming development and etc of an optical shop. It also looked into characteristics of alternative creation patterns such as words mix, typifier, sentence making, part words mix and etc and then, it investigated brand naming examples. Results: Creation of alternative is a phase of brand naming which has to be refined on the basis of creation of abundant alternatives and then to be developed to a brand name. This study suggested examples of brand names of optical shops which were made and adopted by creation of alternative. Conclusions: Creation of alternative in brand naming complies with concept, and it has systemic process and objective selection as an effective way in association of brand and searching words. It is necessary to have brand naming works through creation of alternative for the purpose of individual and strong brand name with desirable association and differentiation of an optical shop.

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Comparison of the Corneal Topography Changes as a Result of Near Task between Myopes and Emmetropes (근시와 정시 사이에서 근거리 작업의 결과로서 각막 지도 변화와 비교)

  • Chen, A.H.;Othman, R.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2003
  • Purpose : The purpose of this study is to investigate the corneal topography changes as a result of near task in myopes and emmetropes. Methods : Thirty university students, aged from 18 to 24 years old, were randomly selected. They were divided into two refractive groups of fifteen each : myopia and emmetropia. The corneal topography of each subject was measured with the Eye-Sys Videokeratography system. Measurements were taken : before and after 30 minutes of near task (copy N10 text at 20 cm working distance). Both simulated keratometry and semi-meridian keratometric map program were used in the data analysis. Results : Our results reveal no significant changes in both simulated keratometry and semi-meridian presentation as a result of near task for both myopes and emmetropes, except a significant change (p<0.05) found at the flattest meridian of the central (3 mm) portion of the corneal topography after near task for emmetropes only. Conclusions : We conclude that the corneal topography, does not change significantly as a result of near task in both myopes and emmetropes.

  • PDF

Comparisons of Phoria Test Among Prism Settings of Von Graefe Technique (Von Graefe법의 프리즘 세팅에 따른 사위검사의 비교)

  • Yu, Dong-Sik;Ha, Eun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.211-218
    • /
    • 2015
  • Purpose: The aim of this study was to compare the differences among prism settings of the von Graefe technique for phoria measurement. Methods: Thirty eight healthy subjects (mean age $22.35{\pm}2.72years$) were tested with eye examination by interview, cover test, and refraction. Phorias were measured in a random order using four prism settings for the von Graefe method: base-in (BI) and base-up (BU), BI and base-down (BD), BU and BI, and BD and BI over the right and left eye, respectively. Results: Among the four prism settings in measurements of lateral and vertical phoria, there were not significant differences at distance, whereas there were significant at near. The reliability of near lateral phoria (ICC: 0.95) was good, but that of near vertical phoria was less reliable (ICC: 0.83). In comparisons of the paired t-test, the 95% limits of agreement, and mean difference between prism settings, BU had more useful than other prism settings at near phoria. Conclusions: Results from this study suggest that the von Graefe test with BU or BU including other setting prisms have useful methods, especially for near phoria measurements.

The Effect of Wettability and Protein Adsorption of Contact Lens by Alginic Acid (알긴산에 의한 콘택트렌즈의 습윤성과 단백질 흡착 효과)

  • Ko, Na Young;Lee, Kyung Mun;Lee, Hyun Mee
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.6
    • /
    • pp.352-358
    • /
    • 2017
  • The addition of alginic acid, a natural polysaccharide, to improve the wettability and the reduction of protein adsorption of hydrogel contact lenses. Hydrogel contact lenses were manufactured with various monomers such as 2-methacryloyloxyethyl phosphorylcholine (MPC) and NVP (N-Vinyl-2-pyrrolidone). Alginic acid was added by by the initial mixing method and the interpenetrating polymer networks(IPN) method. Properties of contact lens such as contact angle, oxygen permeability, and protein adsorption amount were evaluated. The oxygen permeability and wettability of the IPN-treated alginate samples were higher than those of the samples that were not treated with IPN. The physical properties were improved as the concentration of IPN-treated alginic acid increased. Protein adsorption decreased by the addition of alginic acid and further decreased with IPN. In particular, contact lenses containing MPC and NVP significantly decreased protein adsorption. Therefore, the effect of alginate on the functional improvement of contact lens was confirmed.

Study on the Changes of Ophthalmic Plastic Lens due to Heating (가열에 의한 플라스틱 렌즈의 변화 연구)

  • Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The changes in properties of plastic lens due to heating was investigated. Methods: Plastic lenses of -2.00 diopter were heated at 60-100$^{\circ}C$, and then changes of refractive power, surface condition and transmittance were examined. Results: It was shown that the changes of lens surface due to heating happened at 70$^{\circ}C$ for 1h, 75$^{\circ}C$ for 10 min and 100$^{\circ}C$ 10 sec, respectively. More serious crack was occurred in high index lens and at higher heating temperature, respectively, and transmittance decreased depending on the extent of the damage on the surface of lens. Conclusions: Heating at temperatures above 70$^{\circ}C$ drives cracks on the surface of lens. Optician should recommend an appropriate lens considering the wearer's working conditions and guide for paying attention when they use eyeglasses.