• Title/Summary/Keyword: Optometry

Search Result 583, Processing Time 0.024 seconds

Comparison between Subjective and Objective Angle of Deviation Using by Synoptophore and Prism Bar in Strabismus Patients (사시환자에서 Synoptophore와 Prism bar를 이용한 자각적 사시각과 타각적 사시각의 비교)

  • Wi, Dae-Gwang;Joo, Seok-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.79-85
    • /
    • 2010
  • Purpose: We studied the relationship between subjective and objective deviating angle. Methods: Those who were diagnosed with strabismus among the patients who had no systemic diseases that fifty-one subjects (Male; 21, Female; 30) were measured between seven to sixty three years, evaluated to alternate cover test after AR/K (Canon RK-FI, Japan) and retinoscope measured refractive errors. Objective deviating angle was measured using prism bar; and subjective and objective deviating angles were measured and compared using the synoptophore. Results: For the correlation between subjective and objective deviating angles. The differences were $2.6{\pm}2.5{\Delta}$, between subjective deviating angle measured using synoptophore and objective deviating angles measured using synoptophore were $0.7{\pm}1.4{\Delta}$, the average with each other were $1.7{\pm}1.8{\Delta}$, with all the differences highly significant. Conclusions: We thought not only reduced angle of deviating errors and identified the significance in the correlation between subjective and objective deviating angles but also considered to be useful in determining deviating angle of patient with strabismus.

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

A study on the accuracy of optotypes test chart (자동 시력표 정확도에 관한 연구)

  • Song, Kyung-Sek;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.111-118
    • /
    • 2005
  • The optotypes widely used as a necessity in the course of optometry are the world authorized versions which contain items such as the Landolt's rings, Snellen's chart and also Arabian numbers, Korean letters, Pictures and so on. In Korea, the Hahn-chun-suk test chart has been In use generally alolng with Chung-san test chart and Jin-yong-han test chart also in use on the wall. But these sort of test charts hung on the wall have some problems such as the difference in test results owing to the rate of illumination and so a more accurate method is required. To solve the problem of inaccuracy in optometry, the projected type of charts with digital instrument such as the beam projector has been developed lately. This chart projector with consistent high resolution and the ability to provide various charts can help eye examiner perform effective examination and thus is looked positively upon as the automated total optometry system. So in this study our purpose is to examine the accuracy of the projected chart. It was done by comparing it with the frequently used test chart. The results of experiment are as follow. When the projected chart was used, cases that subject read charts one step higher were 10%, two step higher 2% than perfectly corrected vision. When Han-chun-suk test chart was used, cases that subject read charts one step higher were 12%, and two step higher were 4%.

  • PDF

The Effects of Breath Alcohol Concentration Increase on Visual Field and Readable Visual Field (호흡 알코올 농도 증가가 시야 및 가독시야에 미치는 영향)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.153-158
    • /
    • 2016
  • Purpose: This study was aimed to investigate effects of breath alcohol concentration (BrAC) increase on visual field and readable visual field. Methods: 23 males in 20s (average age $21.17{\pm}2.19years$, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program. Then, visual field and readable visual field test with Vision Disk were conducted. Results: Visual field are measured as $74.41{\pm}15.97^{\circ}$, $64.98{\pm}17.93^{\circ}$, and $58.33{\pm}19.01^{\circ}$ (p=0.000) and readable visual field as $21.93{\pm}12.71^{\circ}$, $17.41{\pm}11.36^{\circ}$, $14.26{\pm}9.93^{\circ}$ (p=0.006) in 0.00%, 0.05% and 0.08% BrAC respectively. As breath alcohol concentration increased, both visual field and readable visual field decreased. Conclusions: BrAC increase with drinking could be the cause of safety accident by decreasing visual field and readable visual field, it is necessary to raise awareness.

Comparison and Analysis of Keywords in the Korean Ophthalmic Optics Society Articles to MeSH Terms (한국안광학회지 게재 논문의 주제어와 MeSH 용어의 비교·분석)

  • Kim, Daeyoon;Lee, Min Hyung;Choi, Moonsung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • Purpose: The purpose of this study is to compare and analyze keywords of articles in the Korean Ophthalmic Optics Society to MeSH (Medical Subject Headings) terms. The study hopes to enhance the understanding and usage of MeSH and give fundamental information to the Korean Ophthalmic Optics Society in advance. Methods: A total of 1952 keywords from 409 informative articles published from 2004, Vol 9(1) to 2016, Vol 21(1) were compared with MeSH terms according to the criteria of complete coincidence, incomplete coincidence and complete incoincidence. Results: 439 keywords (22.4%) were completely coincident with MeSH terms, 815 keywords (41.8%) were incompletely coincident with MeSH terms and 693 keywords (35.5%) were completely incoincident with MeSH terms. The most used keyword in MeSH terms is in the order of Myopia, Astigmatism and visual acuity. For the incompletely coincident keywords Refractive error, Soft contact lens, and Phoria were used the most. Finally, the most used keywords in the category of completely incoincident were Accommodative lag and Pseudomonas aeruginosa. Conclusions: It is highly recommended that MeSH terms are selected as controlled keywords to increase usage of searced Korean Ophthalmic Optics Society articles in MEDLINE.

Changes in Optical and Surface Properties of Contaminated Soft Contact Lenses (표면 오염시 소프트콘택트렌즈의 재질에 따른 가시광선투과도 및 표면 변화)

  • Kim, Jungeun;Jung, Boyoung;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.83-89
    • /
    • 2012
  • Purpose: This article was to study the optical and surface properties of soft contact lenses (SCL) exposed to eye make-ups. Methods: Rates of the light transmission of etafilcon A (HEMA based hydrogel lens) and lotrafilcon B (silicone based hydrogel lens) exposed to four different cosmetics over time were investigated. After cleansed with multi-purpose solution (MPS), rates of the light transmission and surface change of lens that were exposed to the cosmetics for 7 consecutive days were analyzed. Results: Visible light transmissions of all lenses exposed to cosmetics decreased to 93.35% (HEMA based hydrogel lens) and 90% (silicone based hydrogel lens) compared with those of the fresh SCLs, such as 97.8% and 96.4%, respectively. It was found that cosmetic residues from powder eye shadow and mascara attached to the lenses were not removed completely when cleansed with MPS. Especially with silicone based hydrogel lens, we found a decrease in visible light transmission of the lens and noticeable particles on lens surface imaged by SEM. Conclusions: Depending on types of eye make-ups and contact lens materials, make-ups were not completely eliminated with current cleansing methods and that caused a decrease in optical property and a change in surface property of the lenses.

Clinical Features of Retinal Correspondence according to Refractive Errors and Deviation Angles (굴절이상과 편위각에 따른 망막대응의 임상적 고찰)

  • Wi, Dae-Gwang;Joo, Seok-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • Purpose: The purpose of this study was to provide useful information for evaluating the sensory function of patients with strabismus by identifying the distribution of anomalous retinal correspondence (ARC) and normal retinal correspondence (NRC) by the degree of refractive errors and deviation angles. Methods: Objective refraction (AR/K, Cannon RK-F1, Japan) and subjective refraction tests were performed on 56 subjects (male: 26, female: 30) by an examiner; objective deviation angle was measured using synoptophore (OCULUS Synoptophore, Germany) with subject' eyes fully corrected for distance, and then subjective deviation angle was measured. Results: In all groups with refractive errors, the number of ARC was larger than that of NRC(67%). Particularly, it was largest in groups with myopia (71%), and in all groups, the number of UARC was larger than that of HARC. In groups with anisometropia, although the numbers of NRC and ARC were same, the number of UARC was larger than that of HARC as in other groups. In the distribution of NRC and ARC by deviation angle, the number of NRC was larger than that of ARC (46%) only at microstrabismus (0 ~ ${\pm}10{\triangle}$). Conclusions: Normal retinal correspondence were the most emmetropia in the retinal response were much higher than in the more hyperopia than the retinal correspondence were more myopia. In addition, the smaller the angle of retinal correspondence Normal over many, but overall, respectively.