• Title/Summary/Keyword: Optimum treatment condition

Search Result 689, Processing Time 0.024 seconds

Control of Contact Angle by Surface Treatment using Sanning Plasma Method (주사 플라즈마 법(SPM)을 이용한 소수성 표면처리)

  • Kim, Young-Gi;Choi, Byoung-Jung;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.10-13
    • /
    • 2010
  • The plasma processing technologies of thin film deposition and surface treatment technique have been applied to many industrial fields. This study is purposed Large-area uniformity and surface treatment on the stainless substrate. We treat surface of stainless by $CF_4$ plasma. $CF_4$ plasma is generated by using SPM(Scanning plasma method)which is kind a of CVD. Generally, SPM has been used for uniform surface treatment using a crossed electromagnetic field. The optimum discharge condition has been studied for the gas pressure, the magnetic flux density and the distance between substrate and electrodes. In result, contact angle is increased by surface treatment using $CF_4$ Plasma. Therefore we expect that SPM to control contact angle is applied to many industries.

Study on the Incinerating Treatment of Rice Hull Produced by RPC and Its Heat Utilization (미곡종합처리장 발생 왕겨폐기물의 소각처리 및 연소열의 활용에 관한 연구)

  • 진영덕;장동일;장동순;김만수;장홍희
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.250-261
    • /
    • 1995
  • This study has been performed to develop an agricultural waste incinerator to combust the rice hull originated from RPC with the typical disposal treatment capacity of 30kg/h and to test performance of the developed incinerator. Experimental results are summarized as following. 1. The optimum feed rate of rice hull of the incinerator is 30kg/h with air ratio of 1.5. 2. The contents of $SO_2$ in flue gas is maximum 18ppm(when rice hull feed rate was 20kg/h and air ratio of 1.5), minimum 7ppm(when rice hull feed rate was 30kg/h and air ratio of 1.5) and average 11ppm. So there is no environmental pollution problem for the incinerating treatment of rice hull of the RPC. 3. The temperature of water of heat exchanger are $53^{circ} C$ and $62^{circ} C$ with water flow rate $3{ell}/min$ and $1.5{ell}/min$ at the optimum combustion condition, respectively. 4. According to theoretical energy calculation, the energy from rice hull combustion may be amounted as much as 80%~190% of energy supplied by kerosene required by RPC.

  • PDF

Optimization of ultrasonification of slaughter blood for protein solubilization

  • Jeon, Yong-Woo
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • In this study, we attempted to solubilize protein in slaughter blood (SB) using ultrasonic technology. The application of ultrasonic technology can make enzymatic degradation of SB more effective, which has no comparable alternative for treatment. The SB was homogenized by grinding it for 10 minutes at 10,000 rpm as a pretreatment for preventing its clotting, and then ultrasonic treatment was attempted to solubilize protein in SB. To maximize the efficiency of ultrasonic treatment for SB, the optimum condition of ultrasonic frequency (UF) was determined to be 20 kHz. To optimize the operation conditions of ultrasonification with 20 kHz of frequency, we used response surface methodology (RSM) based on ultrasonic density (UD) and ultrasonification time (UT). The solubilization rate (SR) of protein (%) was calculated to be $101.304-19.4205X_1+0.0398X_2+7.9411X_1{^2}+0.0001X_2{^2}+0.0455X_1X_2$. From the results of the RSM study, the optimum conditions of UD and UT were determined at 0.5 W/mL and 22 minutes, respectively, and SB treated under these conditions was estimated to have a 95% SR. Also, experimentally, a 95.53% SR was observed under same conditions, accurately reflecting the theoretical prediction of 95%.

Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube (수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향)

  • 황규대;박노성;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

Treatment of Dye-Processing Wastewater with Complex Chemical Coagulants (복합응집제를 이용한 염색가공 폐수의 처리)

  • Seo, Myung-Po;Kim, Byung-So
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • This study provides the optimal conditions treating with the coagulation process and the other chemical treatment processes for dyeing wastewater, especially various dyeing complex wastewater. The results are shown as follows: 1. Optimum reaction condition of pH for ferrous sulfate was the range of 9 to 12. And when 3,000ppm(mg/l) of ferrous sulfate was dosed, the maximum $COD_{Mn}$ removal rate was approximately 40%. 2. In case of ferrous chloride and Bittern as coagulants, optimum pH range was 10 to 11. And maximum $COD_{Mn}$ removal rate was approximately 46% to 50% for dose of 2,000ppm(mg/l) to 6,000 ppm. 3. It is confirmed that the activated sludge process following coagulation precipitation method provides better treatment efficiency than the coagulation precipitation method following the activated sludge process. 4. The purpose of this study was to produce CGF (Cyanoguanidineformaldehyde resin) by organic compounds. 5. The complex coagulation agent by this study is the most economical coagulant with Alum(aluminum sulfate) and the removal efficiency is approximately 54% with 1,000ppm(mg/l) of pH range 6 to 7.

  • PDF

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

Effect of Cellulase on Characteristics of Denim (중성 셀룰라제 처리에 의한 데님의 물성)

  • Kim, Jee-Yeon;Song, Wha-Soon;Kim, Hye-Rim
    • Fashion & Textile Research Journal
    • /
    • v.11 no.3
    • /
    • pp.469-473
    • /
    • 2009
  • Recently, eco-friendly processing has been focused in the textile industry in order to reduce environmental pollutions. Applications of enzyme technology to the textile industry are an example of more environmentally compatible processes. However, there is not enough quantity of referring to denim fabric subjected to enzymatic treatment. In this study, depending on pH, temperature, cellulase concentration, and treatment time, the weight loss of denim fabrics was examined. Characteristics of enzyme-treated fabrics were measured by tearing strength, stiffness, and K/S values. The effect of a non-ionic surfactant (Triton X-100) on characteristics of the enzyme-treated fabrics was evaluated. The cellulase treatment condition on the cotton fabric were optimized to pH 6.0, $50^{\circ}C$, 1%(o.w.f.), and 60minutes. Characteristics of denim fabrics by cellulase treatment in the presence of Triton X-100 did not improve because Triton-X inhibited the activity of enzyme.

Effects of Mixing Condition and Filtration Velocity on Turbidity Removal in a Contact Roughing Filter (접촉여과방식 거친여과지에서 혼화조건과 여과속도가 고탁도 제거에 미치는 영향)

  • Park, Noh-Back;Park, Sang-Min;Hong, Jin-Ah;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.359-366
    • /
    • 2007
  • Slow sand filtrations have been widely used for water treatment in small communities, however their capacity is often limited by high turbidity in the raw water. For this reason, several pre-treatment facilities were required for a slow sand filter. Turbidity removal from the highly turbid raw water was investigated in roughing filters as a pre-treatment process. The roughing filters followed by rapid mixing tank were operated in the form of a contact filtration. In several jar tests, the predetermined optimum aluminium sulfate (alum) doses for turbid water of 30 and 120NTU were 30 and 50mg/L, respectively. At the optimum alum dose, physically optimum parameters including G value of $220sec^{-1}$ and rapid mixing time of 3 minutes were applied to the contact filtration system. Without addition of alum, the filtrate turbidity from the roughing filters, packed respectively with different media such as sand, porous diatomite ball and gravel, was in the range of 5~30NTU at filtration velocities of 30 and 50m/day. However, the application of a contact filtration to roughing filters showed stably lower filtrate turbidity below 1.0NTU at filtration velocity of 30 m/day. Although the filtration velocity increased to 50m/day, filtrate turbidity was still below 1.0NTU in both single and double layer roughing filters. At influent turbidity of 120NTU, the filtrate turbidity was over 5 NTU in the triple layer roughing filter, which shortened the filter run time. The flocs larger than $10{\mu}m$, formed in the rapid mixing tank, were almost captured through the roughing filter bed, while the almost flocs smaller than $10{\mu}m$ remained in filtrate.

Characterization of Optimum Conditions Affecting on Multi-Color Dyeing of Cut Rose (Rosa hybrida 'Akito') (절화장미(Rosa hybrida 'Akito') 복색염색에 미치는 몇 가지 요인의 최적조건 구명)

  • Shim, Sung Im;Nam, Jin Soo;Kim, Hong Yul;Lim, Ki Byung
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.110-114
    • /
    • 2011
  • This experiment was conducted to examine the ideal condition for multiple colors dyeing of cut rose, 'Akito'. Four different colors of dye were applied to make multiple flower colors in cut rose by absorption method. Acidic condition around pH 3.5 showed the fastest absorption speed in all four colors. There is no difference at each pH levels, at part of leaves dyeing, it is more affected colors rather than pH levels in purple and blue colors. From vary concentration of each dyes, $10g{\cdot}L^{-1}$ concentration of dyeing solution gave the best color definition. But it's not significant and result was different by each color in a same concentration. 10 minutes of dyeing performed pastel color and 30 minutes performed the best color definition, but the 30 minutes treatment accompanied with significant dyeing on the leaves also. As a result of this experiment, optimum condition for dyeing cut rose, 'Akito' requires pH 3.5, $5-10g{\cdot}L^{-1}$ of dye concentration and 10-30 minutes treatment.

A Study on Natural Dyeing (4) - Dyeing of Silk Fabric with Amur cork tree Extract - (천연염색에 관한 연구(4) - 황벽에 의한 견 염색 -)

  • Kim, Hye In;Eom, Seong Il;Park, Su Min
    • Textile Coloration and Finishing
    • /
    • v.13 no.5
    • /
    • pp.32-32
    • /
    • 2001
  • Amur cork tree contains yellow natural basic dye largely used for dyeing on silk. Dyeabilities and fastnesses of the colorant on silk fabrics were investigated , According to dye concentration, pH, temperature, time of pre- and post- treatment of mordant, K/S values and fastnesses of the silk fabrics were examined. As a results, K/S values of dyed silk fabrics were increased by pre- and post-treatment with chinese gallotannin. The optimum condition of chinese gallotannin pre-treatment was 0.15% concentration, pH 4, 70℃, and 45min, and that of post-treatment was 0.05% concentration,60℃, and 30min. The wash fastness and the light fastness were enhanced to 4 grades and 2∼3 grades.