• Title/Summary/Keyword: Optimum rate

Search Result 4,172, Processing Time 0.038 seconds

A research of optimum supply reserve levels for stability of power system (전력계통 안정을 위한 공급예비력 적정수준에 대한 연구)

  • Ahn, Dae-Hoon;Kwon, Seok-Kee;Joo, Haeng-Ro;Shin, Jung-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.61-65
    • /
    • 2008
  • Because of the high increasing rate of load demand, these days the necessity of deciding what optimum reserve level is appropriate to most stably supply electricity is being emphasized. This research studies the downward tendency of reverve ratio by analyzing the trend of change of the network scale, reserve, and reserve ratio while optimum reserve has been increased as the network system scale grow up. This means, at this moment 6,000MW is optimum level for short term prospect of power supply and demand. And also, it has been analyzed that, as the annual peak load exceeded 50,000MW, confirming the amount of optimum reserve level is more stable than keeping 10 to 12% reserve ratio.

  • PDF

Study on the Optimum Modification and Modal Analysis of Stiffened Plate of Ship Hull Structure (신체의 Stiffened Plate 구조물의 모우드해석과 최적변경법에 관한 연구)

  • 박성현;박석주;고재용
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.10b
    • /
    • pp.51-58
    • /
    • 2000
  • The purpose of this study is the optimum modification of dynamic characteristics of stiffened plate structure. In the method of the optimization ,finite element method (FEM), sensitivity analysis and optimum structural modification method are used. To begin with, using FEM, the dynamic characteristics of stiffened plate structure is analyzed. Next, rate of change of dynamic characteristic by the change of design variable is calculated using the sensitivity analysis. Then, amount of change of design variable is calculated using this sensitivity value and optimum structural modification method. The change of natural frequency is made to be an objective function. Thickness of plate and cross section moment become a design variable. It is shown that the results are effective in the optimum modification for dynamic characteristics of the stiffened plate structure.

  • PDF

Optimum Vibration Angle for Transporting Granular Materials on Linear Conveyors

  • Keraita, James Nyambega
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.3-7
    • /
    • 2008
  • Vibratory conveyors are widely used in industry to transport granular materials and products. A theoretical point mass model for vibratory conveying was studied. The results agreed well with experimental observations. The model theory included the resting, sliding and flight states of the material. Each state was considered separately when determining the equations of motion. For the coefficients of restitution, values of zero for the normal component and 0.8 for the tangential component were found to be appropriate for modeling the collisions of the granular particles with the conveying surface. The vibration angle had a large influence on the mode and rate of transport. There was an optimum vibration angle for a given set of conditions. The optimum vibration angle decreased and was better defined as the coefficient of friction increased. The results suggest the existence of an optimum dimensionless track acceleration (throw number), which does not support general industrial practice in which the track acceleration is limited when the feed cycle becomes erratic and unstable.

Optimum Design Condition of the Collins Cryocooler (Collins 내동기의 최적 설계조건)

  • Lee, S.W.;Kim, S.Y.;Jung, P.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF

Optimum Design of the CT Type Plate with Varing Thickness (CT형 변후보강재의 최적 설계)

  • 석창성;최용식
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.1
    • /
    • pp.5-13
    • /
    • 1991
  • Fail-safe design of machine elements or structural members is very aim of the whole mankind. Fracture occurs generally from cracks that exist originally or produced from flaws. The most important job we have to do is to make stopping or decreasing the crack growth rate. For fail-safe design variable thickness plates have been used as structural members in practical engineering services. In this paper, optimum design of CT type plate with varlng thickness is studied with the theoritical analysis. The theoritical analysis was based on the stress concentration and nominal stress analysis. From the study, the optimum design curve was determined for use of designing of such structures using the computer analysis program of optimum design.

  • PDF

Oplimum Design Conditions for a Basic Refrigeration Cycle (냉동사이클의 최적 설계조건)

  • Cho, Sung-Whan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.356-361
    • /
    • 1986
  • An optimum design condition for a basic refrigeration cycle is defined as the condition which minimizes the total cost of heat exchanges (condenser and evaporator) and compressor for the refrigeration effect. Thermodynamic properties of ammonia (R717) are approximated by rational functions in order to obtain the optimum condition for a basic refrigeration cycle. Optimum condition depends on the heat capacity rates (mass flow rate times specific heat) of cooling water and brine used in condenser and evaporator. The difference between the cooling water temperature and condensation temperature at the optimum condition increases as the heat capacity rates and the coat of heat exchangers relative to the cost of compressor increase. Numerical examples of optimum conditions are obtained when the condensation temperature is $30^{\circ}C$ and the evaporator temperature is $-10^{\circ}C$.

  • PDF

A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

Optimum Number of Seedling Stands of Rice for High Yield in Direct Water-Seeded Culture (벼 담수직파재배에 있어서 적정립모수 설정)

  • 이철원;성기영;임준택
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.5
    • /
    • pp.405-411
    • /
    • 1994
  • This study was carried out to determined the optimum seeding rate and number of seedling stands per unit area for high yield with two varieties of rice, Nakdongbyeo (Japonica type) and Samgangbyeo (Indica x Japonica type), in direct water-seeded rice culture at Crop Experiment Station. Seeds coated with $CaO_2$ after germination were sowed at May 4 in 7 levels, such as 1.6, 1.8, 2.1, 2.7, 3.5, 4.0, 4.3kg /10a, and the number of seedling stands per square meter was adjusted to be 30, 40, 60, 80, 100, 120, 140 plants, respectively. The maximum number of tillers increased as the seeding rates increased, but the ratio of effective tillers decreased. The critical dates of effective tillering of tested varieties were delayed by the lower seeding rates, and the date was June 18 at the plot of seeding rate with 3.5kg /10a. The number of panicles per unit area increased in accordance with the increased seeding rates. The number of spikelets per panicle in Nakdongbyeo was not affected by the seeding rates, but in Samgangbyeo it decreased as the seeding rate increased. The optimum number of seedling stand per square meter appeared to be 78 in Nakdongbyeo and 120 in Samgangbyeo, respectively. It meant that the optimum seeding rates for Nakdongbyeo and Samgangbyeo were about 2.7 and 4.0kg /10a, respectively.

  • PDF

Fundamental Study on the Application of a Surface Layer using Cold Central-Plant Recycling (플랜트 생산 재활용 상온 혼합물의 도로 표층 적용성에 관한 기초연구)

  • Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.69-76
    • /
    • 2018
  • PURPOSES : This study determined the optimal usage rate of RAP (reclaimed asphalt pavement) using cold central-plant recycling (CCPR) on a road-surface layer. In addition, a mixture-aggregate gradation design and a curing method based on the proposed rate for the surface-layer mix design were proposed. METHODS : First, current research trends were investigated by analyzing the optimum moisture content, mix design, and quality standards for surface layers in Korea and abroad. To analyze the aggregate characteristics of the RAP, its aggregate-size characteristics were analyzed through the combustion asphalt content test and the aggregate sieve analysis test. Moreover, aggregate-segregation experiments were performed to examine the possibility of RAP aggregate segregation from field compaction and vehicle traffic. After confirming the RAP quality standards, coarse aggregate and fine aggregate, aggregate-gradation design and quality tests were conducted for mixtures with 40% and 50% RAP usage. The optimum moisture content of the surface-layer mixture containing RAP was tested, as was the evapotranspiration effect on the surface-layer mixture of the optimum moisture content. RESULTS : After analyzing the RAP recycled aggregate size and extraction aggregate size, 13-8mm aggregate was found to be mostly 8mm aggregate after combustion. After using surface-chipping and mixing methods to examine the possibility of RAP aggregate segregation, it was found that the mixing method contributed very little for 3.32%, and because the surface-chipping method applied compaction energy directly as the maximum assumption the separation ratio was 15.46%. However, the composite aggregate gradation did not change. Using a 40% RAP aggregate rate on the surface-layer mixture for cold central-plant recycling satisfied the Abroad quality standard. The optimum moisture content of the surface-layer mixture was found to be 7.9% using the modified Marshall compaction test. It was found that the mixture was over 90% cured after curing at $60^{\circ}C$ for two days. CONCLUSIONS : To use the cold central-plant recycling mixture on a road-surface layer, a mixture-aggregate gradation design was proposed as the RAP recycled aggregate size without considering aggregate segregation, and the RAP optimal usage rate was 40%. In addition, the modified Marshall compaction test was used to determine the optimum moisture content as a mix-design parameter, and the curing method was adapted using the method recommended by Asphalt Recycling & Reclaiming Association (ARRA).

Evaluation of Preplant Optimum Application Rate of Mixed Expeller Cake in Chinese Cabbage Cultivation at the Field (노지 배추 재배시 혼합유박의 밑거름 적정 시용량 평가)

  • Kim, Seong Heon;Hwang, Hyun Young;Park, Seong Jin;Kim, Seok Cheol;Kim, Myung Sook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.3
    • /
    • pp.41-48
    • /
    • 2019
  • Mixed expeller cake has been one of soil management to improve crop productivity and soil fertility. But, there was a little information on optimum mixed expeller cake application for chinese cabbage. So, in this study, we were evaluated the preplant optimum application rate of mixed expeller cake(MEC) in chinese cabbage cultivation at field. Treatments consist of control, inorganic fertilizer($N-P_2O_5-K_2O$ : $320-78-198kg\;ha^{-1}$), MEC(50, 100, 150% on preplant application standard $110kg\;ha^{-1}$ as N, topdressing : $210kg\;ha^{-1}$ as N). In results, growth characteristics was not significantly different. But, yield was increased when application rate was increased. And MEC 150% treatment showed similar yield as inorganic treatment. There was no significant difference in soil pH, OM, $Av.P_2O_5$, $NH_4-N$ and Ex.K. But, soil EC and $NO_3-N$ were increased when MEC level increased. As a results, MEC 150% can be proposed as preplant optimum application rate of MEC from this study. But abuse of MEC and long-term using caused about salt accumulation in soil.