• 제목/요약/키워드: Optimum Mix

검색결과 326건 처리시간 0.023초

노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트의 최적배합설계 (Mix Design of Exposed Concrete Wall using Self Compacting Concrete)

  • 손유신;이승훈;김규동;김한준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.555-560
    • /
    • 2002
  • The structure of Chosun-ilbo Boopyung factory was desined as exposed concrete. The self compacting concrete(non-vibrating concrete) must be applied to this case because the exposed concrete wall is very thin(200mm) and high(6m), Laboratory tests and semi mock-up test were performed for optimum mix design of the self compacting concrete. As a result, the optimum mixes were observed at the 3-component types(ope, fly-ash, slag powder) that Vp$\geq$0.175, Vw/Vp$\geq$0.95, W=170~175$kgf/m^3$ and B=500~540$kgf/m^3$ Based on this result. we make plan that the pilot productions of batcher plant, the full-scale mock up tests and site application.

  • PDF

초유동 콘크리트용 모르터의 최적배합설계 (Optimum Mix Design on the Mortar of the Super Flowing Concrete)

  • 박칠림;안재현;권영호;이상수
    • 콘크리트학회지
    • /
    • 제10권3호
    • /
    • pp.135-142
    • /
    • 1998
  • 본 연구는 초유동 콘크리트용 모르타르의 물/결합재비 및 고성능 감수제 첨가율에 따른 상대플로우 면적비와 상대깔대기 속도비의 상관관계를 실험으로 검토한 것이다. 구속수비 실험결과, C급 플라이애쉬>F급 플라이애쉬 > 석회석분순으로 나타났기 때문에 F급 플라이애쉬 및 석회석분은 유동성 개선에 효과적인 것으로 나타났다. 또한 모르타르 실험결과, 상대플로우 면적비와 상대깔대기 속도비는 고성능 감수제 첨가율이 일정할 경우 물/결합재비의 변화에 따라 원점을 지나는 직선관계로 나타났지만, 물/결합재비가 일정할 경우에는 고성능 감수제 첨가율의 변화에 따라 원점을 지나는 곡선관계로 나타났다. 따라서, 수식화 모델은 Rm= A. m0.4가 합리적이며, 최적값인 ( m .Rm)=(5.1)을 만족하는 배합조건은 플라이애쉬의 경우 치환율 30%, 물/결합재비 83%이며, 석회분의 경우 치환율30%, 물/결합재비 77%로 판명되었다.

3성분계 시멘트를 사용한 매스콘크리트의 시공사례 (An Application of the Mass Concrete Using Ternary Blended Cement)

  • 권영호;하재담;전성근;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1229-1234
    • /
    • 2001
  • The bottom slab of Inchon LNG in-ground #213 tank is designed as a massive structure witch has a large depth and section. The purpose of this study is to determine the optimum mix design having good workability and low hydration heat for bottom slab concrete and to control the actual concrete quality in site. For this purpose, we select the optimum mix design used ternary blended cement(furnace slag cement+fly ash) and design factors. As test results of actual application, we have finish placing the bottom slab concrete of 23,180㎥ during 68hours with good success and obtain the good quality of fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat in actual data. All test results are satisfied with our specifications for bottom slab concrete and we cut costs as the use of ternary blended cement and the reduction of placing hours.

  • PDF

LNG tank용 초유동 콘크리트의 배합설계 (The required performance of the super flowing concrete for LNG)

  • 권영호;전성근;백승준;이용일;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.463-468
    • /
    • 1999
  • The slurry wall of Inchon LNG receiving terminal tank will be planned the super flowing concrete having properties of high strength (required strength 520kg/$\textrm{cm}^2$), no-vibrating and massive structure in the underground. For the performance of this concrete, we investigate and select all materials, the optimum mix design and sensibility test in the laboratory. As test results, we choose portland blast-furnace slag cement and lime stone powder(L.S.P) as cementitious materials, W/C 41%(W/B 35.4%), S/a 50.8% and unit volume of coasre aggregate 0.30 as optimum mix design. Also test result of the fresh and hardened concrete are satisfied with specifications of slurry wall.

  • PDF

복합섬유를 혼입한 초고강도 콘크리트의 폭렬 특성 평가 (Evaluation on Spalling Properties of Ultra High Strength Concrete with Combined Fiber)

  • 손명학;김규용;민충식;이태규;구경모;윤용상
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2011
  • This study is aimed to draw a optimum combined fiber mix condition to improve spalling resistance and flowability of ultra high-strength concrete. As a result, W/B 12.5% concrete specimens were prevented spalling with PE0.05+ PP0.1, PE0.05+NY0.1 and W/B 12.5% concrete specimens were prevented spalling with all of combined organic fiber mix condition. But There is no significant influence of steel fiber under 5% volume ratios to prevent spalling. In the scope of this study, we suggest that condition of optimum volume ratio PE0.05+NY0.1 is to improve spalling resistance, flowability and residual compressive strength.

  • PDF

MANAGEMENT DECISION-MAKING FOR SUGARCANE FERTILIZER MIX PROBLEMS THROUGH GOAL PROGRAMMING

  • Sharma, Dinesh K.;Ghosh, Debasis;Alade, Julius A.
    • Journal of applied mathematics & informatics
    • /
    • 제13권1_2호
    • /
    • pp.323-334
    • /
    • 2003
  • This paper presents a goal-programming (GP) model for management decision-making for sugarcane fertilizer mix problems. Sensitivity analysis on the priority structure of the goals has been performed to obtain all possible solutions. The study uses Euclidean distance function to measure distances of all possible solutions from the ideal solution. The optimum solution is determined from the minimum distance between the ideal solution and other possible solutions of the problem. The optimum solution corresponds to the appropriate priority structure of the problem in the decision-making context. furthermore, the results obtained from sensitivity analysis on the cost of combination of fertilizers confirm the priority structure.

$23,000m^3$ 대용량 바닥스래브 콘크리트의 시공기술 (Construction technology of the massive bottom slab placed by $23,000m^3$ concrete quantity)

  • 권영호;이현호;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1035-1040
    • /
    • 2003
  • This research investigates the actual data and construction technology of the massive bottom slab placed by $23,000m^3$ concrete quantity in site of the in-ground type LNG receiving terminal having 20,000kl storage capacity. The purpose of this study is to determine the optimum mix design and control the actual concreting procedures including concrete production, transportation, placement, vibrating and curing in site. For this purpose, the optimum mix design using ternary blended cement(furnace slag cement+fly ash) and under piping method having 11 gates and 7 distributors are selected. As test results of actual construction, concrete placement is finished during 68hours with good success and obtained the good quality of the fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat. Also, actual data for all of concrete procedures are proved successful and satisfied with our specifications.

  • PDF

인공경량골재를 활용한 경량 폴리머 콘크리트의 개발 및 바닥배수구조물에의 적용 (Development of Lightweight Polymer Concrete Using Synthetic Lightweight Aggregate and Application for Bottom Draining Structure)

  • 성찬용;김영익;윤준노
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.846-851
    • /
    • 2003
  • This study was performed to develop the lightweight polymer concrete using expanded clay and perlite to improve workability, durability and chemical resistance for bottom draining structure under severe condition. This paper was composed of two parts. One is to invest the physical and mechanical properties of lightweight polymer concrete using synthetic lightweight aggregate, the other is to the develop products for bottom draining structure. Physical and mechanical test for lightweight polymer concrete was performed unit weight, compressive and flexural strength, chemical resistance, accelerated weathering test, absorption ratio and optimum mix for lightweight polymer concrete was designed. Also, products for bottom draining structures by optimum mix of lightweight polymer concrete was made draining trench of small size.

  • PDF

옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험 (Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top)

  • 서유현;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

무극성 플라스틱 소재용 잉크 개발 및 소재의 부착성에 관한 연구 (A Study on Ink of Nonpolar Plastic Material and Material Adhesive Property)

  • 허경영;조가람;구철회
    • 한국인쇄학회지
    • /
    • 제28권2호
    • /
    • pp.13-30
    • /
    • 2010
  • Existing domestic ink market had some problem because of dependence on CPP import, increasing cost, competitive price. For this reason, previous speed of research and developments are very slow. Therefore, develop the new waterborne type of non-chlorine resin, enhance the nation's position with manufacturing outstanding products. Through this thesis, the purpose is mix the polar resin and non-chlorine resin with many proportion and manufacturing better product than existing resin. Pilot production samples have run the test of adhesion, transparency, water resist and resist high pressure car washing. In conclusion, this thesis found that mix acryl Urethane resin and Non-Chlorine resin is the optimum condition.