• 제목/요약/키워드: Optimized analysis

검색결과 3,458건 처리시간 0.03초

매스 콘크리트의 적정 타설높이 산정을 위한 수화열 해석 (Hydrate Heat Analysis for the Determination of Optimized Thickness in Mass Concrete)

  • 신성우;이광수;유석형;김선호;황동규;박기홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 2001
  • The thermal crack in mass concrete is mainly due to the difference of concrete temperature, which is generated by hydration heat of cement. As the thickness of mat foundation increases, the difference of temperature becomes bigger. The purpose of this study is to estimate the optimum placing depth. The temperature of real mat foundation was observed and the thermal analysis by Finite Element Method was executed. Finally, the crack index according to the placing depth was estimated.

  • PDF

MGPSS를 이용한 전력계통안정도 해석 (A Study on the Analysis of Power System Stability using MGPSS)

  • 이상근;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.165-167
    • /
    • 2007
  • This paper presents a analysis method for power system stability using a Modified Genetic-based Power System Stabilized(MGPSS). The proposed MGPSS parameters are optimized using Modified Genetic Algorithm(MGA) in order to maintain optimal operation of generator under the various operating conditions. To improve the convergence characteristics, real variable string is adopted. The results tested on a single machine infinite bus system verify that the proposed controller has better dynamic performance than conventional controller.

  • PDF

실리콘 마이크로머시닝을 이용한 유체증폭기의 제작과 수치해석을 이용한 해석 (A Silicon Micromachined Fluidic Amplifier and Performance Analysis with Computational Fluid Dynamics)

  • 김태현;조동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1963-1967
    • /
    • 1996
  • This paper describes the analysis, design, and silicon-fabrication of a fluidic proportional amplifier, which is the most important element of fluidic logic circuits. First, FEM(finite element method) analyses were performed, using the Fluent computational fluid dynamics program, and design geometries were optimized. Then, a $40\;{\mu}m$-deep amplifier was fabricated in silicon using anisotropic dry etching.

  • PDF

깊은 공핍층을 가지는 우주항공용 촬상소자의 3 차원 특성 분석 (Three-Dimensional Characterizing Analysis of Astronomic CCDs with a deep depletion)

  • Kim, M. H.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 하계학술발표회
    • /
    • pp.228-229
    • /
    • 2000
  • Buried channel JET-X CCDs (Joint European X-ray Telescope Charge Coupled Devices: EEV CCD12) with a deep depletion have been analyzed to provide an optimized condition for a charge storage and transfer. A maximum charge capacity has been found for the supplementary narrow channel by considering the potential distribution as a function of a mobile charge. Analysis for the depletion edges of JET-X CCDs have been successfully performed, showing good agreement with the depths estimated from X-ray detection efficiency measurements [1]. (omitted)

  • PDF

UAV 감시정보정찰 임무분석 및 설계 도구 개발 (Development of Mission Analysis and Design Tool for ISR UAV Mission Planning)

  • 김홍래;전병일;이나래;최성동;장영근
    • 한국항공우주학회지
    • /
    • 제42권2호
    • /
    • pp.181-190
    • /
    • 2014
  • 무인항공기(UAV)를 이용하여 효율적인 감시정찰을 수행하기 위해서는 센서의 고성능, 다중화와 함께 운용상황에 맞는 최적화된 비행경로계획이 요구된다. 이뿐만 아니라 시스템 개발 또는 임무운용 전 임무 효용성 평가, 평시와 전시에 빠른 작전 결정을 위해서는 임무를 가시화할 수 있는 가시화 도구가 필요하다. 본 연구에서는 STK(Systems Tool Kit)와 MATLAB을 통합한 임무 가시화 및 분석 도구를 개발하고 이를 통하여 UAV 감시정보정찰(ISR; Intelligence, Surveillance and Reconnaissance) 임무분석을 수행하였다. 개발된 임무분석 도구에는 비행최적화 뿐만 아니라 장애물 회피 알고리즘, FoM(Figure of Merit) 분석 알고리즘이 적용되어 최적의 임무계획이 가능하도록 하였다.

Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis

  • Geramizadeh, Maryam;Katoozian, Hamidreza;Amid, Reza;Kadkhodazadeh, Mahdi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권2호
    • /
    • pp.59-65
    • /
    • 2018
  • Objectives: This study aimed to optimize the thread depth and pitch of a recently designed dental implant to provide uniform stress distribution by means of a response surface optimization method available in finite element (FE) software. The sensitivity of simulation to different mechanical parameters was also evaluated. Materials and Methods: A three-dimensional model of a tapered dental implant with micro-threads in the upper area and V-shaped threads in the rest of the body was modeled and analyzed using finite element analysis (FEA). An axial load of 100 N was applied to the top of the implants. The model was optimized for thread depth and pitch to determine the optimal stress distribution. In this analysis, micro-threads had 0.25 to 0.3 mm depth and 0.27 to 0.33 mm pitch, and V-shaped threads had 0.405 to 0.495 mm depth and 0.66 to 0.8 mm pitch. Results: The optimized depth and pitch were 0.307 and 0.286 mm for micro-threads and 0.405 and 0.808 mm for V-shaped threads, respectively. In this design, the most effective parameters on stress distribution were the depth and pitch of the micro-threads based on sensitivity analysis results. Conclusion: Based on the results of this study, the optimal implant design has micro-threads with 0.307 and 0.286 mm depth and pitch, respectively, in the upper area and V-shaped threads with 0.405 and 0.808 mm depth and pitch in the rest of the body. These results indicate that micro-thread parameters have a greater effect on stress and strain values.

수환경 내 Estrogen 에스트로젠 활성 검출을 위한 누치 난황전구단백질 유전자 발현의 RT-PCR시험법 (Analysis of Vitellogenin Gene Expression by RT-PCR in Hemibarbus labeo (Cyprinidae) for the Analysis of Estrogenic Activity in Aquatic Environment)

  • 계명찬
    • 생태와환경
    • /
    • 제37권1호통권106호
    • /
    • pp.122-129
    • /
    • 2004
  • In an effort to develop the biomarker for monitoring the contamination of xenoestrogen in the freshwater environment of Korea, reverse transcription-polymerasechain reaction (RT-PCR) analysis of vitellogenin (VTG) gene expression was optimized in Hearisarsus Iaseo, Based on the homology of the VTG cDNA sequences between the common carp and zebra fish, a set of PCR primers for VTG mRNA amplification for H; labo was designed. VTG mRNA level in livers from female and male fishes was analyzed by RT-PCR following single injection of 17 beta estradiol($E_2$ 10 mg $kg^{-1}$ B.W.). As an internal control, beta actin mRNA was amplified. One us of total liver RNA was subjected to RT-PCR. In female the amount of PCR productof VfC gradually increased in the range from 16 to 34 cycles of amplification. On the contrary, in control male, PCR product first detected at 32 cycles of amplification and linearly increased up to 40 cycles of amplification. In $E_2$ injected male liver, the VTC mRNA level was similar to that in the female. Taken together, this result suggests that liver of male H. labo expresses minute amount of VTG mRNA which are2-l6 equivalent of female and that induction of VTG mRNA occurs in male liver after estrogen treatment. In conclusion, the optimized protocol for RT-PCR analysis of VTG mRNA expression in liver of male H. labo will provide the environmental monitoring method for the xenoestrogen contamination in the rivers in Korea.

경수로 연료봉을 지지하는 5×5 지지격자체의 자유진동특성 (Free Vibration Characteristics of 5 × 5 Spacer Grid Assembly Supporting the PWR Fuel Rod)

  • 강흥석;윤경호;송기남;최명환
    • 한국소음진동공학회논문집
    • /
    • 제14권6호
    • /
    • pp.512-519
    • /
    • 2004
  • This paper described the free vibration characteristics of Optimized H Type (OHT) spacer grids (SG) supporting the PWR fuel rod. The vibration test and the finite element (FE) analysis are performed under the free boundary condition and the clamped at two points (or three points) in the bottom which is the same one as the experimental condition for the dummy rod continuously supported by spacer grids. A modal test is conducted by the impulse excitation method using an impulse hammer and an accelerometer, and the TDAS module of the I-DEAS software is used to acquire and analyze the sensor signals. The softwares related to the FE analysis are the I-DEAS for the geometrical shape modeling and meshing, and the ABAQUS for solving. The fundamental frequency of the OHT SG by experiment under a clamped condition at two points is 175.18 Hz, and shows a bending mode. We think there is no resonance between the fuel rod and the SG because the SG's frequency is higher than that of the fuel rod existing in the range from 30 to 120 Hz. The fundamental frequency of the SG under the free boundary condition is 349.2 Hz showing a bending mode, and the results between the test and the analysis have a good agreement with maximum 7 % in error It is also found that the FE analysis model of the OHT SGs to analyze an impact, a buckling and vibration et al. has been generated with reliability.

Generic optimization, energy analysis, and seismic response study for MSCSS with rubber bearings

  • Fan, Buqiao;Zhang, Xun'an;Abdulhadi, Mustapha;Wang, Zhihao
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.347-359
    • /
    • 2020
  • The Mega-Sub Controlled Structure System (MSCSS), an innovative vibration passive control system for building structures, is improved by adding lead rubber bearings (LRBs) on top of the substructure. For the new system, a genetic algorithm is used to optimize the dynamic parameters and distributions of dampers and LRBs. The program uses various seismic performance indicators as optimization objectives, and corresponding results are compared. It is found that the optimization procedure for maximizing the energy dissipation ratio yields the best solutions, and optimized models have consistent seismic performances under different earthquakes. Seismic performances of optimized MSCSS models with and without LRBs, as well as the traditional Mega-Sub Structure model, are evaluated and compared under El Centro wave, Taft wave and 20 other artificial waves. In both elastic and plastic analysis, the model with LRBs shows significantly smaller story drift and horizontal acceleration than those of the other two models, and fewer plastic hinges are developed during severe earthquakes. Energy analysis also shows that LRBs installed in proper locations increase the deformation and energy dissipation of dampers, thereby significantly reduce the kinetic, potential, and hysteretic energy in the structure. However, LRBs do not have to be mounted on all the additional columns. It is also demonstrated that LRBs at unfavorable locations can decrease the energy dissipation for dampers. After LRBs are installed, the optimal damping coefficient and the optimal damping exponent of dampers are reduced to produce the best damping effect.

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.