• Title/Summary/Keyword: Optimization of the exposure dose

Search Result 67, Processing Time 0.023 seconds

Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer (유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가)

  • Kim, Dae-Woong;Kim, Jong-Won;Choi, Yun-Kyeong;Kim, Jung-Soo;Hwang, Jae-Woong;Jeong, Kyeong-Sik;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Purpose: The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Materials and Methods: Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Results: Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) Conclusion: In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  • PDF

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

Phototoxicity Evaluation of Pharmaceutical Substances with a Reactive Oxygen Species Assay Using Ultraviolet A

  • Lee, Yong Sun;Yi, Jung-Sun;Lim, Hye Rim;Kim, Tae Sung;Ahn, Il Young;Ko, Kyungyuk;Kim, JooHwan;Park, Hye-Kyung;Sohn, Soo Jung;Lee, Jong Kwon
    • Toxicological Research
    • /
    • v.33 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • With ultraviolet and visible light exposure, some pharmaceutical substances applied systemically or topically may cause phototoxic skin irritation. The major factor in phototoxicity is the generation of reactive oxygen species (ROS) such as singlet oxygen and superoxide anion that cause oxidative damage to DNA, lipids and proteins. Thus, measuring the generation of ROS can predict the phototoxic potential of a given substance indirectly. For this reason, a standard ROS assay (ROS assay) was developed and validated and provides an alternative method for phototoxicity evaluation. However, negative substances are over-predicted by the assay. Except for ultraviolet A (UVA), other UV ranges are not a major factor in causing phototoxicity and may lead to incorrect labeling of some non-phototoxic substances as being phototoxic in the ROS assay when using a solar simulator. A UVA stimulator is also widely used to evaluate phototoxicity in various test substances. Consequently, we identified the applicability of a UVA simulator to the ROS assay for photoreactivity. In this study, we tested 60 pharmaceutical substances including 50 phototoxins and 10 non-phototoxins to predict their phototoxic potential via the ROS assay with a UVA simulator. Following the ROS protocol, all test substances were dissolved in dimethyl sulfoxide or sodium phosphate buffer. The final concentration of the test solutions in the reaction mixture was 20 to $200{\mu}M$. The exposure was with $2.0{\sim}2.2mW/cm^2$ irradiance and optimization for a relevant dose of UVA was performed. The generation of ROS was compared before and after UVA exposure and was measured by a microplate spectrophotometer. Sensitivity and specificity values were 85.7% and 100.0% respectively, and the accuracy was 88.1%. From this analysis, the ROS assay with a UVA simulator is suitable for testing the photoreactivity and estimating the phototoxic potential of various test pharmaceutical substances.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Usefulness evaluation of Hybrid planning through dosimetric comparision of Three Dimensinal Conformal Radiation Radiotherapy and Hybrid planning for left breast cancer (유방암 환자의 방사선 치료시 Energy와 Wedge를 combine한 Hybrid plan의 유용성 평가)

  • Chae, Moon Ki;Park, Byung Soo;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2014
  • Purpose : To compare the dosimetry for the left breast cancer treatment between three dimensional conformal radiation radiotherapy (3D-CRT) and Hybrid planning and to estimate usefulness of Hybrid planning Materials and Methods : Five patients with left breast cancer were included in the study. They were planned using several different radiotherapy techniques including: 1)open rectangular field, 2)tangential wedge-based field 3)field in field, 4)hybrid planning(energy, wedge combine). For each patient planning was using Light Speed RT-16 CT and PINNACLE planning system-ver.9.2. Hybrid plan was made using same system and using the same targets and optimization goals. We comparing the Homogeneity Index(HI), normal organs at the does-volume histogram(DVH) Results : In all plans, the Homogeneity Index(HI) of Hybrid planning was significantly better than other. Dose comparison of HI= 2D-RT:38.32, TW:38.32, FIF:29.22, HYBRID:30.57. 2D-RT, TW, FIF Hybrid$V_{75_-lung}$=112.33, 125.14, 121.3, 123.78. $V_{50_-lung}$=155.43, 159.62, 157.96, 159.06. $V_{25_-lung}$=199.86, 200.22, 198.65, 200.31. $V_{50_-heart}$=26.07, 27.1, 26.85, 27.17 $V_{30_-heart}$=33.71, 34.37, 34.15, 34.65 Conclusion : In summary, 3D-CRT, Hybrid planning techniques were found to have acceptableCTV coverage in our study. However the Hybrid planning increased radiation dose exposure to normal tissue. If you apply for treatment of inhomogeneity areas like lung, For best results will be achieved.