• 제목/요약/키워드: Optimal point

검색결과 2,292건 처리시간 0.026초

최적제어를 이용한 목표점 지향 유도 (Target Pointing Guidance using Optimal Control)

  • 황익호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.881-888
    • /
    • 1999
  • Target pointing guidance steers a vehicle to point at a target point at a given range Rs. In this paper, vehicle's motions relative to the target point are modeled by differential equations. Then a target pointing guidance law is derived using optimal control theories. In addition, it is shown that the proposed guidance law can achieve the goal of target pointing guidance whatever initial headings are.

  • PDF

탐지확률 분석에 의한 입수점 선정 알고리듬 개발 방안 (A Development Method for Water Entry Point Selection Algorithm by Detection Probability Analysis)

  • 조성봉
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.30-37
    • /
    • 2007
  • In this paper, Water Entry Point Selection Algorithm(WEPSA) for selecting an optimal Water Entry Point of anti-submarine missiles which maximizes Detection Probability about a given target was investigated. WEPSA is a method which decides the position of an optimal Water Entry Point with calculating the target Detection Probability of a torpedo in the whole domain which centered by the target, performing the Monte-Carlo Simulations which include errors for the target informations and for weapon delivery. We can decide an optimal Water Entry Point of anti-submarine missiles which maximizes Detection Probability about a given target with WEPSA, if we get target informations about target range, target bearing, target speed and target course from Combat Systems.

무한 탄성 평판상의 기준점에 전달되는 진동인텐시티의 능동제어 (Active Control of Vibrational Intensity at a Reference Point in an Infinite, Elastic Plate)

  • 김기만
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper, active control of vibrational intensity at a reference point in an infinite, elastic plate was discussed. The plate is excised harmonically by a vibrating source, which has a vertical point force. The optimal condition of controller was investigated to minimize the vibrational intensity being transmitted from the vibrating source to a reference point. Hence the method of feedforward control was employed for the control strategy and then the cost function was evaluated to find the optimal control force. Three types of control force (Vertical force, Moment, and Coupling force (a set of vertical force and moment) ) and controller's positions were examined to define the optimal condition of the controller. The vibrational intensity at a reference point was found to be reduced down to a zero level, compared with the uncontrolled case. Especially maximum reduction of vibrational intensity was achieved when the controller was collinearly positioned between a vibrating source and a reference point.

  • PDF

An Interior Point Method based Reactive Optimal Power Flow Incorporating Margin Enhancement Constraints

  • Song Hwa-Chang;Lee Byong-Jun;Moon Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.152-158
    • /
    • 2005
  • This paper describes a reactive optimal power flow incorporating margin enhancement constraints. Margin sensitivity at a steady-state voltage instability point is calculated using invariant space parametric sensitivity, and it can provide valuable information for selection of effective control parameters. However, the weakest buses in neighboring regions have high margin sensitivities within a certain range. Hence, the control determination using only the sensitivity information might cause violation of operational limits of the base operating point, at which the control is applied to enhance voltage stability margin in the direction of parameter increase. This paper applies an interior point method (IPM) to solve the optimal power flow formulation with the margin enhancement constraints, and shunt capacitances are mainly considered as control variables. In addition, nonlinearity of margin enhancement with respect to control of shunt capacitance is considered for speed-up control determination in the numerical example using the IEEE 118-bus test system.

An Optimal Maximum Power Point Tracking Algorithm for Wind Energy System in Microgrid

  • Nguyen, Thanh-Van;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.382-383
    • /
    • 2018
  • To increase the efficiency of a wind energy conversion system (WECS), the maximum power point tracking (MPPT) algorithm is usually employed. This paper proposes an optimal MPPT algorithm which tracks a sudden wind speed change condition fast. The proposed method can be implemented without the prior information on the wind turbine parameters, generator parameters, air density or wind speed. By investigating the directions of changes of the mechanical output power in wind turbine and rotor speed of the generator, the proposed MPPT algorithm is able to determine an optimal speed to achieve the maximum power point. Then, this optimal speed is set to the reference of the speed control loop. As a result, the proposed MPPT algorithm forces the system to operate at the maximum power point by using a three-phase converter. The simulation results based on the PSIM are given to prove the effectiveness of the proposed method.

  • PDF

전동차 제동장치의 고장데이터와 비용함수를 고려한 유지보수 정책에 관한 연구 (A Study on the Maintenance Policy Considering the Failure Data of the EMU Braking System and the Cost Function)

  • 한재현;김종운;구정서
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.13-19
    • /
    • 2015
  • Railway vehicle equipment goes back again to the state just before when failure by the repair. In repairable system, we are interested in the failure interval. As such, a statistical model of the point process, NHPP power law is often used for the reliability analysis of a repairable system. In order to derive a quantitative reliability value of repairable system, we analyze the failure data of the air brake system of the train line 7. The quantitative value is the failure intensity function that was modified, converted into a cost-rate function. Finally we studied the optimal number and optimal interval in which the costs to a minimum consumption point as cost-rate function. The minimum cost point was 194,613 (won/day) during the total life cycle of the braking system, then the optimal interval were 2,251days and the number of optimal preventive maintenance were 7 times. Additionally, we were compared to the cost of a currently fixed interval(4Y) and the optimum interval then the optimal interval is 3,853(won/day) consuming smaller. In addition, judging from the total life, "fixed interval" is smaller than 1,157 days as "optimal interval".

태양전지 온도 센싱만을 통한 태양광 발전시스템의 최적 운전전압에 관한 연구 (A Study on the Optimal Voltage for MPPT Obtained by only Surface's Temperature of Solar Cell)

  • Minwon Park;In-Keun Yi
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.269-275
    • /
    • 2004
  • Photovoltaic(PV) system has been studied and watched with keen interest due to a clean and renewable power source. But, the output power of PV system is not only unstable but uncontrollable, because the maximum power point tracking (MPPT) of PV system is still hard with the tracking failure under the sudden fluctuation of irradiance. Authors suggest that the optimal voltage for MPPT be obtained by only solar cell temperature. Having an eye on that the optimal voltage point of solar cell is in proportion to its panel temperature, with operating the power converter whose operating point keeps its input voltage to the optimal voltage imagined by the surface's temperature of PV panel, the maximum power point becomes tenderly possible to be tracked. In order to confirm the availability of the proposed control scheme. And both control methods are simulated not only on the various angle of sampling time of switching control, but also with the real field weather condition. As the results of that, the conversion efficiency between PV panel and converter of the proposed control scheme was much better than that of the power comparison MPPT control, and what is better, the output voltage of PV panel was extremely in stable when the optimal voltage for MPPT is obtained by only solar cell temperature.

평판의 1차 고유진동수가 최대가 되는 점지지의 최적위치선정에 관한 연구 (A Study on the Optimal Position Determination of Point Supports to Maximize Fundamental Natural Frequency of Plate)

  • 홍도관;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1165-1171
    • /
    • 2004
  • The free vibration analyses of the isotropic and CFRP laminated composite rectangular plates with point supports at the fix edge is performed by FEM. We showed optimal position and mode shape of point supports that maximized fundamental natural frequency of the isotropic and CFRP laminated composite rectangular plates by each aspect ratio and the number of point supports.

장애물이 있는 경우 단일설비의 최적위치의 결정에 관한 연구 (A Study on Decision of Optimal Point of Single Facility Location when the Application Region is Divided into Two)

  • 강성수
    • 산업경영시스템학회지
    • /
    • 제5권7호
    • /
    • pp.9-15
    • /
    • 1982
  • The rectilinear-distance location problem combines the property of being a very appropriate distance measure for a large number of location problems and the property of being very simple to treat analytically. An obvious question to be asked at the optimal point which is obtained by the rectilinear distance method is, "what if the point is not available as a location site\ulcorner." The point may, for example, be inaccessible or may coincide with the location of another structure, a river, or a municipal park. In this case, one approach that may be employed is to construct contour lines (also called iso-cost or level curves) of the cost function. Contour lines provide considerable insight into the shape of the surface of the total cost function as well as a useful means of evaluating alternative locations for the new facility. But, when there is an obstacle which divides the application area into two. The optimal location(which is acquired by the rectilinear distance method) is not coincide with the minimal cost point and the contour line is occasionally of no use, this paper shows the method of finding a way to decide an optimal point of single facility location in this case.this case.

  • PDF

비선형 내점법을 이용한 최적 조속기 응동 조류계산 (Optimal Governor Response Power Flow with Nonlinear Interior Point Method)

  • 김태균;이병준;송화창;차준민
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1527-1534
    • /
    • 2007
  • This paper proposes a new concept of optimal governor-response power flow (OGPF) to obtain an optimal set of control parameters when the systems are in mid-term conditions after disturbances, ignoring the system dynamics. The idea of GOPF simply comes from the attempt to find an optimal solution of the governor-response power flow (GPF), which is a pre-exiting tool that is used to get power flow solutions that would exist several seconds after an event is applied. GPF incorporates the simplified model of governors in the systems into the power flow equations. This paper explains the concept of OGPF and depicts the OGPF formulation and application of a nonlinear interior point method as the solution technique. Also, this paper includes an example with New England 39-bus test system to illustrate the effectiveness of GOPF.