• 제목/요약/키워드: Optimal capacity

검색결과 1,704건 처리시간 0.036초

열차의 좌석용량 배분을 위한 비선형계획모형 (A Nonlinear Programming Model for the Solution of the Train Seat Capacity Distribution Problem)

  • 김성호;홍순흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.72-79
    • /
    • 2001
  • In this paper we present a nonlinear programming model for the solution of the train seat capacity distribution problem (TSCDP) with a numerical example. The TSCDP model finds the optimal capacity distribution methods which minimize the sum of the differences between the demands and the seat capacities. Also the TSCDP provides the information on the degree of the discrepancy between the demand and the seat capacities. One can use the TSCDP model as a tool for planning train seat capacity planning.

  • PDF

구조물의 진동제어를 위한 MR-damper의 최적 제어력 산정 (Calculating a MR Damper's Optimal Capacity for a Control of Structural Vibration)

  • 허광희;전승곤;김충길;전준용;이진옥;서상구
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.163-169
    • /
    • 2016
  • In the case where a MR-damper is employed for vibration control, it is important to decide on how much control capacity should be assigned to it against structural capacities (strength and load, etc). This paper aims to present a MR-damper's control capacity suitable for the capacities of the structure which needs to be controlled. First, a two span bridge was built equipped with a MR-damper, which constitutes a two-span MR-damper control system. Then, inflicting an earthquake load on the system, a basic experiment was performed for vibration control, and a simulation was also carried out reflecting specific control conditions such as MR-damper and rubber bearing. The comparison of the results against each other proved their validity. Then, in order to calculate an optimal control capacity of the MR-damper, structural capacity was divided into eleven cases in total and simulated. For each case, an additional load of 30 KN was inflicted everytime, thereby increasingly strengthening structural capacity. As a result of the study, it was found that the control capacity of MR-damper of 30 KN was safely secured only with lumped mass of more than 150 KN(case 6). Therefore, it is concluded the MR-damper showed the best performance of control when it exerted its capacity at around 20% of structural capacity.

토지이용 시나리오별 용수공급 분석에 따른 빗물이용시설 최적 용량 결정 (Determination of Optimum Capacity Rainwater Utilizing Facilities by Analysis of the Water Supply by Land Use Scenario)

  • 임석화;김병성;류경식;이상진
    • 대한토목학회논문집
    • /
    • 제41권4호
    • /
    • pp.387-397
    • /
    • 2021
  • 우리나라 농업용수 공급은 대부분 저수지를 통한 공급 방법을 채택하고 있어 그 의존도가 매우 높다. 이에 적용 가능한 대체 수원을 활용하여 저수지 의존도를 경감시키고 안정적인 농업용수 공급이 이루어져야 한다. 따라서, 본 연구에서는 토지이용 별 시나리오를 구성하여 대체 수원인 빗물과 하수재이용수를 활용한 최적의 용수공급방안에 대하여 분석하고 빗물 이용시설의 최적 용량을 결정하는 연구를 수행하였다. 분석 결과 기존 논농사 지역을 하우스로 변경하여 빗물을 최대로 활용할 경우 안정적인 공급이 이루어졌고, 실제 빗물을 활용하고 있는 농장에서 1 mm의 강우에 약 0.82 ton의 용량이 필요한 것으로 분석되었다. 이에 최적의 시나리오를 MODSIM을 통해 결정한 빗물 저류 용량과 실제 모니터링을 통해 결정한 저류 용량을 집수면적당 저류 용량 비율로 분석한 결과 각각 약 31, 32 %로 유사하게 나타났으며, 빗물 이용시설의 최적 용량은 약 5,796,000 ton ~ 6,182,400 ton 으로 분석되었다.

데이터 트래픽 특성을 고려한 적정 채널 용량 산정 (Estimation of Channel Capacity for Data Traffic Transmission)

  • 박현민
    • 한국콘텐츠학회논문지
    • /
    • 제17권3호
    • /
    • pp.589-595
    • /
    • 2017
  • 본 논문에서는 다양한 이동통신 서비스의 원활한 데이터 전송을 위한 적정 채널 용량의 산정 방법을 제시한다. 서비스 유형별 패킷 전송에 대한 허용 지연시간 기준을 모두 충족하기 위해서는 적정한 채널용량이 확보되어야 한다. 이러한 채널 산정 과정을 분석하기 위해 디지털 통신시스템의 이산시간 운영특성과 패킷 기반 트래픽의 집단 발생 상황을 $Geo^x$/G/1 비선점형 우선순위 대기행렬로 모델링하였다. 휴리스틱한 평균 대기시간 분석 방법을 이용하여 다양한 전송 우선순위를 갖는 서비스 유형별 평균 대기시간을 도출하였다. 이를 이용하여 무선 서비스 지연에 관한 품질 척도(QoS)를 충족시키는 적정 채널 용량의 산정 과정을 제시하였다. 본 연구 결과인 적정 채널 용량 산정 방법은 이동통신 데이터 서비스의 품질 만족도를 높이고 네트워크의 경제적 운용에 도움이 될 것으로 기대한다.

대용량 통신처리시스템에서 사용자 이용성향과 ISDN를 고려한 망정합장치의 회선용량 분배에 관한 연구 (An Optimal Capacity Allocation Problem in Designing advanced Information Communication Processing System)

  • 김영일;김찬규;이영호;김영휘;류근호
    • 한국통신학회논문지
    • /
    • 제25권5B호
    • /
    • pp.809-819
    • /
    • 2000
  • 이 연구는 온라인 서비스를 제공하는 AICPS의 정합장치 용량 분배 및 성능을 분석하고자 한다. AICPS은 전화망, 패킷망, ISDN, 인터넷 및 프레임 릴레이망을 연동하는 게이트웨이 시스템이다. 기존의 PC통신망에 관한 연구는 전화망과 데이터망간 연동에 한정되어 있었고 사용자 이용성향도 고려하지 못했다. 따라서 이 연구에서는 앞으로 급격히 증가할 ISDN서비스를 반영하고 한번 호접속으로 PC통신, 인터넷을 동시에 이용할 수 있는 통신환경을 반영한 모형을 제시하였다. 이 모형에서는 사용자 이용성향은 마코프 과정을 이용해서 분석하였고 PC통신과 인터넷을 동시에 이용한는 경우에 호손율을 산출하기 위해 확률 배낭(Stochastic Knapsack) 방법을 이용하였다. 그리고 시뮬레이션을 통해 분석적 방법에 의한 분석과 비교하였다. 제안된 모형을 통해 전체의 호손율을 최소로 하는 AICPS의 망정합장치 용량을 배분할 수 있다.

  • PDF

Reversible Watermarking with Adaptive Embedding Threshold Matrix

  • Gao, Guangyong;Shi, Yun-Qing;Sun, Xingming;Zhou, Caixue;Cui, Zongmin;Xu, Liya
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4603-4624
    • /
    • 2016
  • In this paper, a new reversible watermarking algorithm with adaptive embedding threshold matrix is proposed. Firstly, to avoid the overflow and underflow, two flexible thresholds, TL and TR, are applied to preprocess the image histogram with least histogram shift cost. Secondly, for achieving an optimal or near optimal tradeoff between the embedding capacity and imperceptibility, the embedding threshold matrix, composed of the embedding thresholds of all blocks, is determined adaptively by the combination between the composite chaos and the average energy of Integer Wavelet Transform (IWT) block. As a non-liner system with good randomness, the composite chaos is suitable to search the optimal embedding thresholds. Meanwhile, the average energy of IWT block is calculated to adjust the block embedding capacity, and more data are embedded into those IWT blocks with larger average energy. The experimental results demonstrate that compared with the state-of-the-art reversible watermarking schemes, the proposed scheme has better performance for the tradeoff between the embedding capacity and imperceptibility.

도시지역의 최적 배수관망 설계를 위한 Risk Safety Factor 관계의 설정 (Derivation of the Risk-Safety Factor Relation for Optimal Storm Sewer Design in Urban Area)

  • 김문모;이원환;조원철
    • 대한토목학회논문집
    • /
    • 제12권4호
    • /
    • pp.129-134
    • /
    • 1992
  • 본 논문은 도시유역의 최적 배수관망설계를 위한 위험도-안전도계수 관계를 설정하는 것이다. 배수관망의 신뢰도 분석을 위하여는 하수관의 용량과 하중을 결정하는 식을 구성하는 여러가지 매개변수들의 불확실성이 고려되어야 하며, 이에 따른 위험도를 결정하게 된다. 본 연구에서는 신뢰도 분석기법을 유역면적 $381,000m^2$인 성산 유수지 유역에 적용하였다. 하수관망의 용량을 결정하는 식으로는 Darcy-Weisbach식을, 하중을 결정하는 식으로는 합리식을 사용하였으며, 하수관의 용량과 설계유량과의 비로 나타나는 안전도계수를 구하여 이를 하수관망의 위험도와 상관시켰다. 이에 따라 재현기간별 위험도-안전도계수를 얻었으며, 이는 배수관망의 최적설계에 이용될 수 있다.

  • PDF

PSTN과 PSDN을 연결한 데이터 통신망의 회선할당에 관한 연구 (An optimal link capacity problem of on-line service telecommunication networks)

  • 김병무;이영호;김영휘;김유환;박석지;김주성
    • 대한산업공학회지
    • /
    • 제24권2호
    • /
    • pp.241-249
    • /
    • 1998
  • In this paper, we seek to find an optimal allocation of link capacity in a data communication network. The architecture of the data communication network considered in the study is an online-service network based on public switched telephone network(PSTN) and packet switched data network(PSDN). In designing the architecture of the network, we need to deal with various measures of quality of service(QoS). Two important service measures are the call blocking probability in PSTN and the data transfer delay time in PSDN. Considering the tradeoff between the call blocking probability and the data transfer delay time in the network, we have developed the optimal link capacity allocation model that minimizes the total link cost, while guarantees the call blocking probability and the data transfer delay time within an acceptable level of QoS. This problem can be formulated as a non-linear integer programming model. We have solved the problem with tabu search and simulated annealing methods. In addition, we have analyzed the sensitivity of the model and provided the insight of the model along with computational results.

  • PDF

Studies for the Sustainable Management of Oyster Farms in Pukman Bay, Korea: Estimation of Carrying Capacity from Food Availability

  • Jeong, Woo-Geon;Cho, Sang-Man;Lee, Sang-Jun
    • Fisheries and Aquatic Sciences
    • /
    • 제12권2호
    • /
    • pp.118-129
    • /
    • 2009
  • To develop a sustainable management model for oyster farming in Pukman Bay, Korea, we estimated the carrying capacity for oyster farming using food availability data. Optimal culture densities were calculated to be 124-133 individuals per unit flux area ($m^2$) and 310-330 individuals per string. The present annual production is approximately 1,038 tons/year, which is 87% of the estimated maximum yield of 1,193 tons/year. Therefore, considering annual fluctuations and a critical buffer to reduce ecological impacts, the current level is within optimal conditions. During periods of increased water temperature, energy demand was largely met by high primary production. The food supply significantly decreased as the harvest season approached, and 10 out of 21 oyster farms had a deficient food supply for at least 1 month. Therefore, these farms (39% of the farms within the bay) exceeded optimal densities.

아산호 용수공급용량 유지를 위한 적정 준설량 산정 (Estimation of the Optimal Dredge Amount to Maintain the Water Supply Capacity on Asan-Lake)

  • 장태일;김상민;강문성;박승우
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.45-55
    • /
    • 2006
  • This study analyze the hydrologic conditions and the effects of selected runoff characteristics as an attempt to estimate the optimal dredge amount for Asan Lake in Korea. The runoff feature was calculated by utilizing the water balance simulation from DIROM (Daily Irrigation Reservoir Operation Model), which allowed changes in landuse to be quantified using remote sensing for 14 years. The distribution of prospective sediment deposits was been tallied based on the changes in landuse, and quantity of incoming sediment estimated. From these findings, we were then able to simulate the fluctuation of water level, gauging the pumping days not already in use, to determine the frequency of the distribution for around the. requirement annual water storage and the changing water level. The optimal dredge amount was calculated on the basis of the distribution of frequency, taking into account the design criteria for agricultural water with the 10-year frequency of resistant capacity.