• 제목/요약/키워드: Optimal Load Distribution

검색결과 280건 처리시간 0.022초

다양한 곡률을 가진 공기 동압 베어링의 축방향 부하특성 해석 (Analysis of Axial Load Characteristics of Air-Dynamic Bearings of Various Curvatures)

  • 최우천;신용호;최정환
    • 한국정밀공학회지
    • /
    • 제17권3호
    • /
    • pp.129-135
    • /
    • 2000
  • Air-dynamic bearings are increasingly used in supporting small high-speed rotating bodies. This study investigates the effects of design parameters on the axial stiffness of spiral-grooved air bearings of various curvatures. Design parameters are fundamental clearance, groove depth, and bearing number. The pressure distribution at the clearance between the stator and rotor of the bearing is obtained by solving the Reynolds equation, and the supporting load and the axial linear stiffness are calculated from the pressure distribution. It is found that a larger curvature increases the axial linear stiffness more and that there exist an optimal groove depth for the linear stiffness of the air bearing. It is also found that the linear stiffness has a linear relationship with the bearing number.

  • PDF

마찰형 감쇠기가 설치된 다자유도 비선형 건물의 응답특성 (Response Characteristics of a Nonlinear MDOF Structure with Friction Dampers)

  • 이성경;박지훈;문병욱;민경원;이상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.561-567
    • /
    • 2007
  • This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.

  • PDF

PC 클러스터 기반 병렬 유전 알고리즘-타부 탐색을 이용한 배전계통 고장 복구 (PC Cluster Based Parallel Genetic Algorithm-Tabu Search for Service Restoration of Distribution Systems)

  • 문경준;이화석;박준호;김형수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.375-387
    • /
    • 2005
  • This paper presents an application of parallel Genetic Algorithm-Tabu Search (GA-TS) algorithm to search an optimal solution of a service restoration in distribution systems. The main objective of service restoration of distribution systems is, when a fault or overload occurs, to restore as much load as possible by transferring the do-energized load in the out of service area via network reconfiguration to the appropriate adjacent feeders at minimum operational cost without violating operating constraints, which is a combinatorial optimization problem. This problem has many constraints with many local minima to solve the optimal switch position. This paper develops parallel GA-TS algorithm for service restoration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solutions of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper $10\%$ of the population to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC cluster system consists of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the validity of the proposed method, proposed algorithm has been tested with a practical distribution system in Korea. From the simulation results, we can find that the proposed algorithm is efficient for the distribution system service restoration in terms of the solution quality, speedup, efficiency and computation time.

배전계통에서 GA를 이용한 접속변경 순서 결정 방법 (Study of Connection Process in Distribution systems using Genetic Algorithm)

  • 오선;서정갑
    • 한국위성정보통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.6-11
    • /
    • 2011
  • 본 논문에서는 전기 배전시스템에서 부하단의 실시간 변화에 따른 배전시스템의 안정적인 운용을 가능하게 하기 위해서 유전자 알고리즘 방법을 사용한 방법에 대해서 연구하였다 배전시스템의 안정적인 운용은 각각의 배전 구역에서의 안정성을 향상시킨다는 중요한 장점을 가지고 있다 본 논문에서는 배전계통에서 가장 어려운 것으로 평가되는 접속절차에 대한 접근을 기반의 신뢰성 모델에 기초하여 수행하였다 유전자 알고리즘은 일반적인 생물계에서의 생존을 위한 진화의 과정을 구현한 것으로서 본 논문에서는 개의 노드와 개의 배전영역을 갖는 배전시스템을 대상으로 유전자 알고리즘을 적용한 배전시스템 최적화를 구현하였다.

선형계획법을 적용한 임의 분할 불가능한 부하 분배계획 (Indivisible load scheduling applied to Linear Programming)

  • 손경호;이달호;김형중
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.382-387
    • /
    • 2005
  • There are many studies on arbitrarily divisible load scheduling problem in a distributed computing network consisting of processors interconnected through communication links. It is not efficient to arbitrarily distribute the load that comes into the system. In this paper, how to schedule in case that arbitrarily indivisible load comes into the system is studied. Also, the cases of the divisible load mixed with the indivisible load that come into network were dealt with optimal load distribution in parallel processing system by scheduling applied to linear programming.

  • PDF

임플란트 나사의 안정성 (Stability of implant screw joint)

  • 정재헌;곽종하;장두익
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

최적 재폐로방식 선정에 관한 연구 (A Study on the Determination of Optimal Auto-reclosing)

  • 김일동;한경남;임성정;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.861-863
    • /
    • 1997
  • This paper presents a reliability and power quality taken account of the reclosing scheme on the power distribution system. To determine the optimal reclosing scheme, the simple radial distribution system is modelled, and analyzes quantitatively the effect of customer's load to the number of reclosing. The result of the analysis shows that the determined reclosing scheme can satisfy both the reliability and the power quality in the power distribution system.

  • PDF

지식베이스를 이용한 배전계통의 최적재구성 (The Optimal Distribution Feeder Reconfiguration Using Knowledge Base)

  • 조시형;최병윤;김세호;이재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.99-101
    • /
    • 1993
  • This paper presents an approach to feeder reconfiguration in order to achieve an efficient operation of distribution systems utilizing knowledge base. The optimal feeder reconfiguration in this study eliminates various abnormal states which will create feeder overloads and feeder constraint problems. and will also accomplish minimum power loss of the distribution systems under normal operating condition by means of branch exchanges to change the status of sectionalizing switches with experiences of the experts. For an effective implementation of feeder reconfiguration, a best-first tree searching strategy based on heuristics is employed to evaluate the various alternatives of load transfer. The heuristic exchange of branches results in reduction of the search space as a means of implementing the best-first searching strategy.

  • PDF

A Four Pole, Double Plane, Permanent Magnet Biased Homopolar Magnetic Bearing with Fault-Tolerant Capability

  • Na, Uhn-Joo
    • 한국산업융합학회 논문집
    • /
    • 제24권6_1호
    • /
    • pp.659-667
    • /
    • 2021
  • This paper develops the theory for a novel fault-tolerant, permanent magnet biased, 4-active-pole, double plane, homopolar magnetic bearing. The Lagrange Multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrices for the failed bearing. If any of the 4 coils fail, the remaining three coil currents change via a novel distribution matrix such that the same opposing pole, C-core type, control fluxes as those of the un-failed bearing are produced. Magnetic flux coupling in the magnetic bearing core and the optimal current distribution helps to produce the same c-core fluxes as those of unfailed bearing even if one coil suddenly fails. Thus the magnetic forces and the load capacity of the bearing remain invariant throughout the failure event. It is shown that the control fluxes to each active pole planes are successfully isolated. A numerical example is provided to illustrate the new theory.