• 제목/요약/키워드: Optimal Dose

검색결과 572건 처리시간 0.032초

인삼의 효과에 관한 세포생리학적 연구 -제 I 편 Saccharomyces의 분열에 미치는 영향- (A Cellular Physiological Study on the Effects of Korean Ginseng -Part I. Effects on the Division of Saccharomyces-)

  • 정너팔
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.45-49
    • /
    • 1969
  • The effects of water extracts and powder of Korean ginseng on the division of Saccharomyces cerevisiae were studied. 1. The addition of several doses of water extracts and powder of ginseng to the yeast medium of Moyer and Coghill showed various promoted division of Saccharomyces. 2. The optimal dose of ginseng on tile division of Saccharomyces (0.08% dry ginseng medium solution per $10\;cells/mm^3$) could be recognized. 3. On the culture for 24 hours at $18^{\circ}C$, the cell number of control group was $13.25{\times}10^3\;cells/mm^3$ and that of the optimal dose group of water extracts of ginseng was $23.20{\times}10^3\;cells/mm^3$. On the culture, for 24 hours at $25^{\circ}C$, the cell number of control group was $16.85{\times}10^3\;cells/mm^3$ and that of the optimal dose group was $30.20{\times}10^3\;cells/mm^3$. The increasing rate of cell divison by the ginseng was about twice than that of control group. The optimal dose treatment of ginseng at $18^{\circ}C$ was more effective than control group at $25^{\circ}C$. 4. On the culture for 24 hours at $18^{\circ}C$, the increasing rate of water extracts of ginseng was 75.1%, and the rate of ginseng powder was 7.6%. On the culture for 24 hours at $25^{\circ}C$, the rate of water extracts of ginseng was 79.8%, and the rate of ginseng powder was 57.2%. Therefore water extracts of ginseng was more effective than ginseng powder of same dry weight, and the promoted effect of ginseng powder at $25^{\circ}C$ was more effective than at $18^{\circ}C$.

  • PDF

흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구 (A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination)

  • 김영근;양숙;왕태욱;김은혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구 (Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator)

  • 이철수
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

복합 부가필터 종류에 따른 선량 및 화질 분석 (Dose and Image Quality Analysis According to The Type of Composite Additional Filter)

  • 명노범;임소연;유세종;김성호;전민철
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.147-154
    • /
    • 2020
  • 본 연구에서는 복합 부가필터(Composite added filtration) 4가지 종류(알루미늄, 니켈, 구리, 아연)를 두께별로 조합하여 X-선 감약에 따른 선량감소와 최적의 영상을 평가하였다. 선량과 화질을 평가는 RQR9 표준 선질을 설정한 X선 발생장치, 면적선량계 그리고 ICY 프로그램이 사용되었다. 화질평가 항목(PSNR, RMSE, SSIM)에서는 PSNR값이 30 dB 이상이 되는 영상들만을 분석하였다. 그 결과 선량평가에서 가장 우수한 조합은 3 mmAl + 0.6 mmNi(0.16µGy㎡)이었고, 화질평가에서 가장 우수한 필터는 0.9 mmAl (PSNR 34.24dB, RMSE 79.52, SSIM 0.24)이었다. 본 연구에서는 선량적 측면과 화질적 측면이 언급되었기에 향후 환자의 피폭선량과 최적의 영상에 대한 더 많은 연구가 필요할 것으로 사료된다.

Optimal dose and volume for postoperative radiotherapy in brain oligometastases from lung cancer: a retrospective study

  • Chung, Seung Yeun;Chang, Jong Hee;Kim, Hye Ryun;Cho, Byoung Chul;Lee, Chang Geol;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • 제35권2호
    • /
    • pp.153-162
    • /
    • 2017
  • Purpose: To evaluate intracranial control after surgical resection according to the adjuvant treatment received in order to assess the optimal radiotherapy (RT) dose and volume. Materials and Methods: Between 2003 and 2015, a total of 53 patients with brain oligometastases from non-small cell lung cancer (NSCLC) underwent metastasectomy. The patients were divided into three groups according to the adjuvant treatment received: whole brain radiotherapy (WBRT) ${\pm}$ boost (WBRT ${\pm}$ boost group, n = 26), local RT/Gamma Knife surgery (local RT group, n = 14), and the observation group (n = 13). The most commonly used dose schedule was WBRT (25 Gy in 10 fractions, equivalent dose in 2 Gy fractions [EQD2] 26.04 Gy) with tumor bed boost (15 Gy in 5 fractions, EQD2 16.25 Gy). Results: The WBRT ${\pm}$ boost group showed the lowest 1-year intracranial recurrence rate of 30.4%, followed by the local RT and observation groups, at 66.7%, and 76.9%, respectively (p = 0.006). In the WBRT ${\pm}$ boost group, there was no significant increase in the 1-year new site recurrence rate of patients receiving a lower dose of WBRT (EQD2) <27 Gy compared to that in patients receiving a higher WBRT dose (p = 0.553). The 1-year initial tumor site recurrence rate was lower in patients receiving tumor bed dose (EQD2) of ${\geq}42.3Gy$ compared to those receiving <42.3 Gy, although the difference was not significant (p = 0.347). Conclusions: Adding WBRT after resection of brain oligometastases from NSCLC seems to enhance intracranial control. Furthermore, combining lower-dose WBRT with a tumor bed boost may be an attractive option.

경막외 Morphine 부작용 치료를 위한 Nalbuphine의 적정 정주 용량 (Optimal Dose of Intravenous Nalbuphine for Treatment of Side Effects of Epidural Morphine)

  • 한찬수;최일석;김일호
    • The Korean Journal of Pain
    • /
    • 제10권1호
    • /
    • pp.48-53
    • /
    • 1997
  • Background : Epidural morphine provides excellent postoperative analgesia but is often associated with side effects such as nausea, vomiting and pruritus. It has been reported that mixed agonist-antagonist, nalbuphine can reverse side effects of epidural morphine without compromising analgesia. This study was designed to compare the efficacy of each intravenous dose of nalbuphine for treatment of side effects following epidural morphine. Methods : All patients received continuous infusion(2 ml/hr) of epidural morphine-local anesthetics mixture(morphine 4 mg, 1% mepivacaine 50 ml and 0.25% bupivacaine 50 ml) following a loading dose (morphine 2 mg with 1% mepivacaine 7 ml). Patients requesting treatment for nausea, vomiting and pruritus randomly received intravenous nalbuphine 0.05 mg/kg(Group 1; n=20), 0.1 mg/kg(Group 2; n=20) or 0.15 mg/kg(Group 3; n=20). The severity of nausea, vomiting, pruritus, degree of pain, sedation and vital sign were assessed prior to and 30 min after each dose. Results : The severity of nausea, vomiting and pruritus decreased significantly in all groups(p<0.01). Pain and sedation scores were unchanged in all groups. One patient received nalbuphine 0.15 mg/kg, complained of dizziness, agitation and palpitation. His blood pressure who had increased to 170/100 after first dose. Conclusions : This study suggests that intravenous nalbuphine is good for treatment of side effects following epidural morphine, and the dose of Group 1, 0.05 mg/kg, may be recommended as an optimal dose.

  • PDF

Gamma Knife Radiosurgery for Trigeminal Neuralgia : Review and Update

  • Lee, Seunghoon;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권5호
    • /
    • pp.633-639
    • /
    • 2022
  • Accurate diagnosis of trigeminal neuralgia (TN) is the starting point for optimal treatment. Gamma knife radiosurgery (GKRS) is currently regarded as one of the first-line treatment options for medically refractory TN. GKRS is a less invasive treatment with a low risk of complications than other surgical procedures that provides a favorable pain control Barrow Neurological Institute (BNI) I-IIIb rate of >75% at short-term follow-up. Drawbacks of GKRS include the latency period before pain relief and higher recurrence rate compared with microvascular decompression. Therefore, repeat treatment is necessary if the initial GKRS was effective but followed by recurrence. The concept of dose rate and the biologically effective dose of radiation has been actively studied in radiation oncology and is also applied in GKRS for TN to achieve high safety and efficacy by prescribing the optimal dose. Recent progress in functional imaging, such as diffusion tensor imaging, enables us to understand the pathophysiology of TN and predict the clinical outcome after GKRS. Here, we review TN, GKRS, and recent updates, especially in the concepts of radiation dose, diffusion tensor imaging studies, and repeat treatment in GKRS for TN.

감마선 조사가 귀리(Avena sativa)의 감수성에 미치는 영향 (Effects of Gamma-ray Irradiation on Radio Sensitivity in Oat (Avena sativa))

  • 류재혁;권순재;임승빈;정상욱;안준우;김진백;최기춘;김원호;강시용
    • 한국자원식물학회지
    • /
    • 제29권1호
    • /
    • pp.128-135
    • /
    • 2016
  • 귀리 종자에 감마선을 조사한 후 발아율과 생존율 및 초기 생장 특성을 조사하여 돌연변이 유도를 위한 적정 방사선량을 구명하고, DNA 손상 정도를 평가 하였다. 연구의 결과, 발아율은 500 Gy 이상의 선량에서 급격히 감소하였고, 단순회귀분석으로 평가한 LD50 선량은 392 Gy였다. 감마선 조사 30일 후 초장, 생체중, 근장, 분얼수를 조사한 결과 대조구와 100∼200 Gy 처리구간 차이가 없었으며, RD50 선량은 초장과 생체중은 411 Gy로 동일하였고, 근장 403 Gy, 분얼수 394 Gy였다. LD50과 RD50 선량을 바탕으로 결정한 귀리의 적정 조사선량은 300~400 Gy였다. Comet assay로 DNA 손상 정도를 측정한 결과, 파종 7일 후에는 모든 감마선 처리구가 대조구와 비교하여 DNA 손상이 크게 나타났으며, 파종 30일 후에는 300 Gy 이상의 처리구에서 대조구보다 유의성 있는 DNA 손상이 관찰되어 생육형질과 동일한 경향이었다. 선량과 생장, 코멧분석 결과간의 상관관계를 분석한 결과, 머리의 비율을 제외한 다른 조사 항목에서 높은 상관관계를 나타내었다. M2 세대의 생육특성은 400 Gy 이상에서 생육이 감소하였고, 돌연변이 양상은 주로 고선량에서 단간, 불임이었다.

감마선 조사가 감초(Glycyrrhiza uralensis)의 초기 생육 및 DNA 손상에 미치는 영향 (Effects of Gamma-ray Irradiation on Growth Characteristics and DNA Damage in Licorice (Glycyrrhiza uralensis))

  • 류재혁;임승빈;김동섭;안준우;김진백;김상훈;강시용
    • 방사선산업학회지
    • /
    • 제8권2호
    • /
    • pp.89-95
    • /
    • 2014
  • This study was conducted to determine the optimal dose of gamma-ray on the growth and nucleus DNA damage for mutation breeding in licorice. Gamma-rays irradiated to dry seeds with various doses (0 to 1000 Gy). Significant decreases in germination rate (%), survival rate (%) and growth characteristics (plant height, number of leaves, root length and fresh weight) were observed by dose of increased. $LD_{50}$ (lethal dose) was approximately 400 Gy to 500 Gy. Also, reduction doses ($RD_{50}$) of plant height, number of leaves, root length and flash weight were 428 Gy, 760 Gy, 363 Gy and 334 Gy, respectively. It is supplest that the optimal dose of gamma irradiation for licorice mutation induction might be about 400 Gy in this study. We also conducted comet assay to observe nucleus DNA damage due to gamma irradiation. In comet assay, a clear difference was identified over 300 Gy treatments. With increasing doses of gamma-ray in the range of 100 to 1000 Gy, the rate of head DNA was decreased significantly from 92.88% to 73.09%. Tail length(${\mu}m$) was increased as the dose of increased over 300 Gy. Growth characteristics (Germination rate, Survival rate, plant height, number of leaves, root length and fresh weight) were highly negatively ($P{\leq}0.01$) correlated with dose. While the tail length was highly positively ($P{\leq}0.01$) correlated with dose.

방사선을 이용한 생물폐자원의 멸균선량 결정 (Radiation Sterilization Dose of Biowastes)

  • 이영근;장화형;한갑진;김진규;김재성
    • 한국환경농학회지
    • /
    • 제17권4호
    • /
    • pp.368-370
    • /
    • 1998
  • In order to determine the optimal radiation dose for the sterilization of biowastes, the bioburden, frequencies and radiosensitivities of bacteria, mold and fungi in rice straw, chaff, corn stover and sawdust was observed before and after ${\gamma}-ray$ irradiation. Radiation sterilization dose of rice straw, chaff, com stover and sawdust was calculated as 17.7, 17.6, 15.6 and 20.0kGy, respectively, from the mutual compensation of screening dose and derived dose on the basis of $10^{-3}$ SAL. This method could be acceptable for the sterilization of various biowastes including food, pharmaceuticals, etc.

  • PDF