• 제목/요약/키워드: Optical path difference

검색결과 60건 처리시간 0.026초

Assessment and Correction of the Spectral Quality for the Savart Polarization Interference Imaging Spectrometer

  • Zhongyi Han;Peng Gao;Jingjing Ai;Gongju Liu;Hanlin Xiao
    • Current Optics and Photonics
    • /
    • 제7권5호
    • /
    • pp.518-528
    • /
    • 2023
  • As an effective means of remotely detecting the spectral information of the object, the spectral calibration for the Savart polarization interference imaging spectrometer (SPIIS) is a basis and prerequisite of information quantification, and its experimental calibration scheme is firstly proposed in this paper. In order to evaluate the accuracy of the spectral information acquisition, the linear interpolation, cubic spline interpolation, and piecewise cubic interpolation algorithms are adopted, and the precision of the quadratic polynomial fitting is the highest, whose fitting error is better than 5.8642 nm in the wavelength range of [500 nm, 820 nm]. Besides, the inversed value of the spectral resolution for the monochromatic light is greater than the theoretical value, and the deviation between them becomes larger with the wavelength increasing, which is mainly caused by the structural design of the SPIIS, together with the rationality of the spectral restoration algorithm and the selection of the maximum optical path difference (OPD). This work demonstrates that the SPIIS has achieved high performance assuring the feasibility of its practical use in various fields.

Arrayed-Waveguide Grating의 경로 오차 측정을 위한 저 간섭 광원 간섭계 (Low Coherence Interferometer for Measurement of Path Length Errors in Arrayed-Waveguide Grating)

  • 송영기;허남춘;정영철
    • 한국광학회지
    • /
    • 제15권6호
    • /
    • pp.539-546
    • /
    • 2004
  • 고밀도 AWG (Arrayed-Waveguide Grating)의 광 경로차 에러를 정확히 측정하기 위하여 개선된 형태의 저간섭 광원 간섭계를 구성하였고, 새로운 해석방법을 제시하였다. 소프트웨어적인 방법을 이용하여 하드웨어면에서 실험장치를 간략화할 수 있었다. 또한 인접 간섭신호들 사이의 실제 피크 위치 차이를 보간법을 이용하여 정확히 측정할 수 있다. 특정 AWG의 위상 에러를 측정하였고, 이 에러를 가정하여 계산한 파장 투과 특성이 실제 AWG의 파장투과 특성과 유사함을 보임으로써, 제시한 측정 장치의 정확성을 입증하였다.

In Situ Sensing of Copper-plating Thickness Using OPD-regulated Optical Fourier-domain Reflectometry

  • Nayoung, Kim;Do Won, Kim;Nam Su, Park;Gyeong Hun, Kim;Yang Do, Kim;Chang-Seok, Kim
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.38-46
    • /
    • 2023
  • Optical Fourier-domain reflectometry (OFDR) sensors have been widely used to measure distances with high resolution and speed in a noncontact state. In the electroplating process of a printed circuit board, it is critically important to monitor the copper-plating thickness, as small deviations can lead to defects, such as an open or short circuit. In this paper we employ a phase-based OFDR sensor for in situ relative distance sensing of a sample with nanometer-scale resolution, during electroplating. We also develop an optical-path difference (OPD)-regulated sensing probe that can maintain a preset distance from the sample. This function can markedly facilitate practical measurements in two aspects: Optimal distance setting for high signal-to-noise ratio OFDR sensing, and protection of a fragile probe tip via vertical evasion movement. In a sample with a centimeter-scale structure, a conventional OFDR sensor will probably either bump into the sample or practically out of the detection range of the sensing probe. To address this limitation, a novel OPD-regulated OFDR system is designed by combining the OFDR sensing probe and linear piezo motors with feedback-loop control. By using multiple OFDR sensors, it is possible to effectively monitor copper-plating thickness in situ and uniformize it at various positions.

경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사 (MTF and wavefront error testing of large aperture optical system using unequal path interferometer)

  • 송종섭;조재흥;이윤우;송재봉;양호순;이인원
    • 한국광학회지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 2005
  • 기준광과 탐사광의 경로길이가 매우 크게 차이가 나는 경로길이 불일치 간섭계(unequal path interferometer)를 이용한 직경 300mm 카세그레인 형태의 인공위성 망원경과 같은 대구경 광학계의 변조전달함수(modulation transfer function : MTF)와 파면오차를 동시에 측정하는 방법을 제안하고 이를 실험적으로 확인하였다. 이러한 경로불일치 간섭계를 이용한 측정시스템에서 필요한 평행한 시준광을 만들기 위해서 쌍방향 층밀리기 간섭계를 사용하였으며, 파면오차를 측정하기 위해서 직경 400 mm인 비축 포물경을 사용하는 긴 광경로차의 대구경 피조우 간섭계를 사용하였다. 또한 회전하는 확산판을 이용하여 레이저 광을 부분가간섭광으로 바꿈으로써 피조우 간섭계의 파장으로부터 쉽게 MTF를 측정할 수 있었다.

An Efficient Design Technique for the Flattened Transfer Function of Arrayed Waveguide Grating

  • Jung Jae-Hoon;Moon Hyung-Myung;Kwak Seung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.33-36
    • /
    • 2006
  • This paper describes an efficient optimal design method for an arrayed waveguide grating (AWG) with flattened transfer function. The objective function is the norm of the difference between calculated and target spectra. To analyze the AWG transfer function, the Fresnel-Kirchhof diffraction formula was employed and the design variable was optical path difference of each array waveguide. The (1+1) Evolution Strategy was applied to an eight-channel coarse wavelength division multiplexing (CWDM) AWG as the optimization tool. The optimized transfer function will considerably improve the system performance.

Study of Propagation of Light along an Acupuncture Meridian

  • Choi, Chun-Ho;Soh, Kwang-Sup;Lee, Sang-Min;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • 제7권4호
    • /
    • pp.245-248
    • /
    • 2003
  • Propagation of light along a pericardium meridian is measured and compared with that along a non-meridian path one cm away from the meridian. Source-light is illuminated on the Nei-Guan(PC6) and propagated light is detected at three points along the meridian. Four reference points are one cm away from the corresponding meridian points, respectively. Light propagates better along the meridian than the reference path with more than twenty percent difference for all the subjects tested.

초고속 광통신을 위한 16-Channel AWG 파장다중화기의 설계에 관한 연구 (A Study on the Design of 16-Channel AWG Wavelength Division Multiplexer for Super High-Speed Optical Communication)

  • 조명현
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.148-154
    • /
    • 2005
  • Various methods for analyze optical components which are necessary before the fabrication of optical circuit component and as its applications, designing method of Wavelength Division Multiplexer(WDM) filter using arrayed-waveguide grating(AWG) is paper. In the case of analyzing uniform optical waveguide, effective index method(EIM), harmonic expansion method are used, and in the case of non-uniform optical waveguide, beam propagation method(BPM) are used. In this paper, to use arrayed-waveguide grating as WDM filter of centered wavelength of $1.55{\mu}m$ and wavelength spacing of 0.8nm, all of the parameter of AWG is calculated by the HEM and the BPM using EIM. As a result of calculation, free spectral range is 12.8nm, focal length $9336.55{\mu}m$, path difference $129.36{\mu}m$ and the number of slab waveguide 91 when the distance of core center to center on row land circle is $20{\mu}m$.

링 공명기의 경로치 제어를 위한 피에조 구동 거울의 설계 (The Design of Piezo-driven mirror for the Path Length Control in a Ring Resonator)

  • 이정익
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2551-2556
    • /
    • 2009
  • 링 레이저 자이로스콥의 주 동작은 폐경로 내의 상대 전파에 대한 위상 차에 의존한다. 공명 블록위에 설치 된 반사경들이 순항 파를 형성한다. 따라서, 공명 블록의 차원 정확도가 빔의 순항 경로에 영향을 미친다. 링의 공진 내에서 안정된 광학 빔 경로를 유지하기 위해서 피에조로 구동되는 이동거울이 공명 블록의 열팽창이나 기계적 변형하에서 경로치 제어를 하고자 선택되었다. 이 논문에서는 피에조 구동 거울의 탄성거동에 대한 수학적 설명을 제시하였다. 이 설명은 피에조 구동 거울의 개념 설계에도 적용될 수 있다.

정밀 광학 부품의 복굴절 측정 방법에 관한 연구 (A Study on The Birefringence Measurement in Precision Optical Product)

  • 민인기;고영배;권창오;윤경환
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.90-94
    • /
    • 2012
  • Recently, injection molding process became more popular than ever to produce large quantities of high precision products. Extensive studies have been conducted for reducing the residual stresses and birefringence in injection-molded optical products. Flow-induced and thermally-induced stresses and birefringence have been found as two main sources during injection molding process. Generally, quantitative value of birefringence can be measured with polarizing microscope using the compensator. However, it is difficult to measure low order retardation with microscope, so developing a measurement system for low order optical path difference is in need. In the present paper, a system using Photo Elastic Modulator (PEM) is demonstrated to measure low phase retardation in injection-molded products.

  • PDF

광경로차가 있는 광학기기의 변조전달함수에 관한 연구 (A Study on the MTF of optical system with optical path difference)

  • 최규식;장원석;오재익
    • 한국항행학회논문지
    • /
    • 제16권3호
    • /
    • pp.518-525
    • /
    • 2012
  • 광학기기가 대상물체를 영상으로 완벽하게 재현할 수는 없으므로 이러한 광학기기의 특성을 평가하는 방법으로서 변조전달함수(MTF)가 보편적으로 사용된다. 그런데 한편으로 렌즈의 수차가 적어지면 광학시스템 구경의 회절과 수차 사이의 반응이 매우 복잡해지므로 기존의 MTF의 방법으로는 광학기기를 평가하기가 어렵다. 이 경우에는 렌즈의 수치구경, 탈초점, 광경로차 및 위상차를 고려한 MTF를 구해야 한다. 본 논문에서는 이러한 방법으로서 가장 보편적으로 알려진 베셀함수를 이용하여 이의 타당성을 검증하고 실례를 통하여 이를 보여주고자 하였다.