• Title/Summary/Keyword: Optical injection

Search Result 525, Processing Time 0.023 seconds

Construction of a microwave free electron laser and studies of its characteristics (마이크로파 자유전자 레이저의 제작 및 동작특성 연구)

  • 이관철;정기형
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.43-49
    • /
    • 1992
  • A microwave free electron laser which consists of Marx generator, vacuum diode, bifilar helical wiggler, and guide solenoid was designed and constructed. The analysis of the magnetic field distributions of the bifilar helical wiggler and computer simulation of electron trajectories with the perpendicular effect of space charges led to the conclusion that the magnetic field distributions are suitable for the electron beam injection. Output frequency in a single $TE_{11}$

  • PDF

Reducing Efficiency Droop in (In,Ga)N/GaN Light-emitting Diodes by Improving Current Spreading with Electron-blocking Layers of the Same Size as the n-pad

  • Pham, Quoc-Hung;Chen, Jyh-Chen;Nguyen, Huy-Bich
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.380-390
    • /
    • 2020
  • In this study, the traditional electron-blocking layer (EBL) in (In,Ga)N/GaN light-emitting diodes is replaced by a circular EBL that is the same size as the n-pad. The three-dimensional (3D) nonlinear Poisson, drift-diffusion, and continuity equations are adopted to simulate current transport in the LED and its characteristics. The results indicate that the local carrier-density distribution obtained for the circular EBL design is more uniform than that for the traditional EBL design. This improves the uniformity of local radiative recombination and local internal quantum efficiency (IQE) at high injection levels, which leads to a higher lumped IQE and lower efficiency droop. With the circular EBL, the lumped IQE is higher in the outer active region and lower in the active region under the n-pad. Since most emissions from the active region under the n-pad are absorbed by the n-pad, obviously, an LED with a circular EBL will have a higher external quantum efficiency (EQE). The results also show that this LED works at lower applied voltages.

A Study on the Effects of Micro Cavity on the HTL Thicknesses on the Top Emission Organic Light Emitting Diode (유기발광 다이오드의 정공수송층 두께에 따른 미소 공진 효과의 영향에 관한 연구)

  • Lee, DongWoon;Cho, Eou Sik;Seong, Jin-Wook;Kwon, Sang Jik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.91-94
    • /
    • 2022
  • Top emission organic light-emitting diode is commonly used because of high efficiency and good color purity than bottom - emission organic light-emitting device. Unlike BEOLED, TEOLED contain semi-transparent metal cathode. Because of semi-transparent cathode, micro cavity effect occurs in TEOLED. We optimized this effect by changing the thickness of hole injection layer. Device consists of is indium-tin-oxide / N,N'-Di-[(1-naphthyl)-N,N'-diphenyl]-1,1'-biphenyl-4,4'-diamine (x nm) / tris-(8-hydroxyquinoline) aluminum (50nm) / LiF(0.5nm) / Mg:Ag (1:9), and we changed NPB thickness which is used as HTL in our device in order to study how micro cavity effects are changed by optical path. As the results, NPB thickness at 35nm showed the current efficiency of 8.55Cd/A.

Hyperkinetic Rat Model Induced by Optogenetic Parafascicular Nucleus Stimulation

  • Moonyoung Chung;Young Seok Park
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.121-132
    • /
    • 2023
  • Objective : The parafascicular nucleus (PF) plays important roles in controlling the basal ganglia. It is not well known whether the PF affects the development of abnormal involuntary movements (AIMs). This study was aimed to find a role of the PF in development of AIMs using optogenetic methods in an animal model. Methods : Fourteen rats were underwent stereotactic operation, in which they were injected with an adeno-associated virus with channelrhodopsin (AAV2-hSyn-ChR2-mCherry) to the lateral one third of the PF. Behavior test was performed with and without optical stimulation 14 days after the injection of the virus. AIM of rat was examined using AIM score. After the behavior test, rat's brain was carefully extracted and the section was examined using a fluorescence microscope to confirm transfection of the PF. Results : Of the 14 rats, seven rats displayed evident involuntary abnormal movements. AIM scores were increased significantly after the stimulation compared to those at baseline. In rats with AIMs, mCherry expression was prominent in the PF, while the rats without AIM lacked with the mCherry expression. Conclusion : AIMs could be reversibly induced by stimulating the PF through an optogenetic method.

Fabrication of AlGaN-based vertical light-emitting diodes

  • Bae, Seon Min;Jeon, Hunsoo;Lee, Gang Seok;Jung, Se-Gyo;Kim, Kyoung Hwa;Yi, Sam Nyung;Yang, Min;Ahn, Hyung Soo;Yu, Young Moon;Kim, Suck-Whan;Cheon, Seong Hak;Ha, Hong-Ju;Sawaki, Nobuhiko
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.75-77
    • /
    • 2012
  • The AlGaN-based vertical light-emitting diodes (LEDs) on thick GaN epilayer were fabricated by a hydride vapor phase epitaxy with multi sliding boat system. The optical and electrical characteristics of AlGaN-based vertical LEDs were evaluated using a scanning electron microscopy, electroluminescence and I-V measurements. The AlGaN-based vertical LEDs structure has hexagonal symmetry, 500 ㎛ in diameter and above 67 ㎛ in growth thickness. At the room-temperature, the broaded strong peak and relatively high intensity peak were gradually measured at 405 nm with increasing injection current. And a forward operator voltage was measured to be about 7.5 V.

Growth and optical characteristics of the non-phosphor white LED by mixed-source HVPE (혼합소스 HVPE에 의한 비형광체 백색 LED의 성장과 광 특성)

  • Kim, E.J.;Jeon, H.S.;Hong, S.H.;Han, Y.H.;Lee, A.R.;Kim, K.H.;Ha, H.;Yang, M.;Ahn, H.S.;Hwang, S.L.;Cho, C.R.;Kim, S.W.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.61-65
    • /
    • 2009
  • In this paper, we report on the growth and optical characteristics of white-LED without fluorescent material. The growth of DH(double heterostructure) with AlGaN active layer was performed on a n-GaN/(0001) $Al_{2}O_{3}$ by the mixed-source HVPE and multi-sliding boat. The CRI(color rendering index) of packaging device charged in the range 72-93 with CIE chromaticity coordinates(x=$0.26{\sim}0.34$, y=$0.31{\sim}0.40$). And CCT(correlated color temperature) values was measured $5126{\sim}10406K$ with increasing injection current. The CIE point of conventional phosphor white LED shifts blue region, but cm point of non-phosphor white LED shifts opposite direction. These results show the mixed-source HVPE can be possible to newly fabricate method of phosphor free white LED with high CRI value.

Dependence of $O_2$ Plasma Treatment of ITO Electrode on Electrical and Optical Properties of Polymer Light Emitting Diodes (ITO 투명전극의 $O_2$ 플라즈마 처리가 고분자 유기발광다이오드의 전기.광학적 특성에 미치는 영향)

  • Gong, Su-Cheol;Back, In-Jea;Yoo, Jea-Huyk;Lim, Hun-Sung;Yang, Sin-Huyk;Shin, Sang-Bea;Shin, Ik-Seup;Chang, Gee-Keun;Chang, Ho-Jung
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.3
    • /
    • pp.93-97
    • /
    • 2006
  • Polymer light emitting diodes (PLEDs) are expected to be commercialized as next generation displays by advantages of the fast response time, low driving voltage and easy manufacturing process for large sized flexible display. Generally, the electrical and optical properties of PLEDs are affected by the surface conditions of transparent electrode. The PLED devices with ITO/PEDOT:PSS/PVK/PFO-poss/LiF/Al structures were prepared by using the spin coating method. For this, PEDOT:PSS(poly(3,4-ethylenedioxythiophene):poly(styrene sulfolnate)) Al 4083 and PVK(N-vinylcabozole) were used as hole injection and transport layers. The PFO-poss(poly(9,9-dioctylfluorene)) was used as the emitting layer. The dependence of $O_2$ plasma treatment of ITO electrode on the electrical and optical properties of PLEDs were investigated. The sheet resistances increased slightly with an improved surface roughness of ITO electrode as the RF power increased during $O_2$ plasma treatment. The PLED devices prepared on the ITO/Glass substrates, which were plasma-treated at 40 watt in RF power for 30 seconds under 40 mtorr $O_2$ pressure, showed the maximum external emission efficiency of 0.86 lm/W and the maximum luminance of $250\;cd/m^2$, respectively. The CIE color coordinates are ranged $X\;=\;0.13{\sim}0.18$ and $Y\;=\;0.10{\sim}0.16$, showing blue color. emission.

Two Cases of Long-Term Changes in the Retinal Nerve Fiber Layer Thickness after Intravitreal Bevacizumab for Diabetic Papillopathy (당뇨병유두병증에서 유리체강내 베바시주맙 주입술 후 망막시경섬유층 두께의 장기간 변화 2예)

  • Kim, Jong Jin;Im, Jong Chan;Shin, Jae Pil;Kim, In Taek;Park, Dong Ho
    • Journal of The Korean Ophthalmological Society
    • /
    • v.54 no.9
    • /
    • pp.1445-1451
    • /
    • 2013
  • Purpose: To report long-term changes in the average retinal nerve fiber layer (RNFL) thickness in 2 patients who had intravitreal bevacizumab (IVB) injection for diabetic papillopathy. Case summary: A 36-year-old patient with diabetes complained of decreased visual acuity (20/200) in the right eye. The fundus examination showed optic disc swelling in both eyes. The average RNFL thickness based on optical coherence tomography (OCT) increased to $278{\mu}m$ and Goldmann perimetry showed nasal visual field defect in the right eye. The IVB was injected into the right eye. Three weeks after the IVB injection, RNFL thickness decreased to $135{\mu}m$ and visual acuity improved to 20/25 in the right eye. However, RNFL thickness increased from 126 to $207{\mu}m$ and visual acuity decreased to 20/32 in the left eye. Thus, IVB was injected into the left eye. In week 3, RNFL thickness decreased to $147{\mu}m$ and visual acuity improved to 20/20 in the left eye. At 12 months after IVB injection, RNFL thickness was $87{\mu}m$ in the right eye and $109{\mu}m$ in the left eye. A 57-year-old patient with diabetes complained of decreased visual acuity (20/200) and showed optic disc swelling in the right eye. The average RNFL thickness increased to $252{\mu}m$ and Goldmann perimetry showed an enlarged blind spot in the right eye. IVB was injected into the right eye. After 3 weeks, RNFL thickness decreased to $136{\mu}m$ and visual acuity improved to 20/70 in the right eye. Six months after IVB injection, RNFL thickness was $83{\mu}m$ in the right eye. Conclusions: Visual acuity progressively improved within 3 weeks and RNFL thickness measured by spectral domain OCT showed progressive thickness reduction in 2 cases of diabetic papillopathy patients who had IVB injections.

Protection Effect of Undariia pinnatifida sporophylls-derived Fucoidan in Rat Lung Injury from X-ray Irradiation (미역포자엽추출 푸코이단의 X-선 조사 흰쥐 폐장상해에 대한 방오기능 평가)

  • Kim, Hong-Tae;Jeong, Eui-Sook;Chung, Duck-Soo;Kim, Ki-Hong;Kim, Jong-Ki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • The radioprotect effects of fractinated fucoidan, derived from Undaria pinnatifida sporophylls, were examined in lung injured rats treated with partial body irradiation. The right lung of Sprague-Dawley rats, eight separately grouped by including radiation only control group (ROG) and fucoidan+radiation treated group (FRG), were treated with various fraction of Undaria-derived fucoidan every other day by intraperitoneal injection 6 days prior to irradiation and during monitoring at 24 hours, 48 hours, 2 weeks, 4 weeks and 12-weeks post-irradiation of 6 Mev/2 Gy. The rats were euthanized at completion of the treatment. Tissue samples from the injured lung, fixed in formaldehyde using lung perfusion prior to extraction, were H/E stained for histological analysis using optical microscopy. Interstitial congestion (IC), hemorrhage in alveolar sac (HM), number of macrophage (MP) and alveolar wall thickness (AWT) as a measure of early indication of fibrosis were measured. AWTs in 24 hrs post-irradiation rats increased in comparison with $2.49{\pm}0.06{\mu}m$ of control group by $3.67{\pm}0.09{\mu}m$, $3.21{\pm}0.08{\mu}m$ (p=0.013), $2.98{\pm}0.08{\mu}m$ (p=0.00) in ROG, F1-fucoidan+radiation, and F3-fucoidan+radiation group, respectively. AWT of the ROG was further increased by $4.30{\pm}0.13{\mu}m$ in the 12 weeks post-irradiation group, but AWT on average was $2.56{\pm}0.05{\mu}m$ in the FRG. MP in the 24 hrs post-irradiation group markedly increased in comparison with $2.6{\pm}0.34/0.14\;mm^2$ of the control group by $8.0{\pm}1.48/0.14\;mm^2$ in the ROG, but it was only $3.6{\pm}0.48/0.14\;mm^2$ in F3-FRG. MP in the 12 weeks post-irradiation group was $7.2{\pm}1.28/0.14\;mm^2$ in ROG, but it was $2.8{\pm}0.37/0.14\;mm^2$ or $2.4{\pm}0.4/0.14\;mm^2$ (p<0.05) in the FRG. In addition, increased IC and HM in ROG were relatively smaller in FRG of the 24 hr and 12 weeks post-irradiation rats. In conclusion, Undaria pinnatifida sporophylls-derived fucoidan fractions exhibited radioprotectant activity on injured rat lung subjected to X-ray irradiation. However, success was variable according to the fractions and also time of injection post injury.

Studies on the Relationship between Number of Repeat and Duration of Estrous Behavior in Hanwoo and Holstein Cattle (한우와 젖소의 발정 행동 반복수와 지속 시간에 관한 연구)

  • Son, Jun-Kyu;Park, Seong-Jai;Baek, Kwang-Soo;Choi, You-Lim;Lee, Myeung-Sik;Kim, Sang-Bum;Kim, Hyeon-Shup;Shin, Seung-Oh;Park, Choon-Keun;Park, Soo-Bong
    • Journal of Embryo Transfer
    • /
    • v.23 no.3
    • /
    • pp.141-145
    • /
    • 2008
  • The objective of this study was to investigate the relationship between behavioral signs and duration of estrous in Hanwoo and Holstein cattle for the prediction of optical insemination. Fifty two of 58 and 71 of 89 in Hanwoo and Holstein cows or heifers showed estrous exhibition within 72 h after 2 days following $PGF_{2}\alpha$ administration, respectively. The number of mounting and standing heat were 54.2 and 57.6, 59.4 and 53.5, 42.0 and 30.8 and 16.2 and 10.7 times in Hanwoo cows, Hanwoo heifers, Holstein cows and Holstein heifers, respectively. Duration of mounting were no significantly difference for Hanwoo cows ($21.2\pm11.3$), Hanwoo heifers ($19.9\pm11.4$), Holstein cows ($8.7\pm4.4$) and Holstein heifers ($16.9\pm8.0$). Duration of standing heat were significantly (p<0.05) shorter for Holstein cows ($5.4\pm3.4$) than for Hanwoo cows ($17.1\pm9.6$), Hanwoo heifers ($16.5\pm6.3$) and Holstein heifers ($15.0\pm7.2$). Time until mounting after injection of $PGF_{2}\alpha$ were significantly (p<0.05) longer for Holstein cows ($56.3\pm11.45$) than for Hanwoo cows ($42.71\pm10.44$), Hanwoo heifers ($36.6\pm8.21$) and Holstein heifers ($40.70\pm6.15$). Time until standing heat after injection of $PGF_{2}\alpha$ were significantly (p<0.05) longer for Holstein cows ($61.6\pm8.92$) than for Hanwoo cows ($46.2\pm11.49$), Hanwoo heifers ($42.7\pm6.06$) and Holstein heifers ($44.1\pm6.72$). In the results of this study, duration of standing heat was the shortest in Holstein cows ($5.4\pm3.4$). The estimation of estrous with Holstein cows has more difficulty because to significantly shorter duration of standing heat than for Hanwoo cows, Hanwoo heifers and Holstein heifers. The standing heat can be a good predictor for time of ovulation but it is concluded that mounting behavior could be the best predictor for time of ovulation.