• Title/Summary/Keyword: Optical density

Search Result 1,833, Processing Time 0.029 seconds

Effect of Water Extract of Omija(Schizandra chinensis) on Growth of Yoghurt Starter (오미자(Schizandra Chinensis) 물 추출액이 Yoghurt Starter의 증식에 미치는 영향)

  • 홍경현;남은숙;박신인
    • Food Science of Animal Resources
    • /
    • v.23 no.4
    • /
    • pp.333-341
    • /
    • 2003
  • The effect of water extract of Schizandra chinensis on the growth of yoghurt starter was investigated in order to manufacture the drink type yoghurt added with water extract of Schizandra chinensis. It was the most desirable extraction conditions for Schizandra chinensis to soak in 50 times of water for 15 hours at 20$^{\circ}C$. The water extract of Schizandra chinensis showed pH 3.07, 2.39% acidity, 1.10% total sugars, and 0.15 optical density for color. The water extract of Schizandra chinensis was added to MRS broth medium from 0.1% to 1.0% and the medium was fermented by 4 types of lactic acid bacteria such as Lactobacillus acidophilus, Lactobacillus casei, Lactobacillus bulgaricus, and Streptococcus thermophilus. The addition of water extract of Schizandra chinensis inhibited the growth of the lactic acid bacteria. The maximum addition amounts of water extract of Schizandra chinensis was 0.9% for Lac. acidophilus, 0.8% for Lac. casei, 0.2% for Lac. bulgaricus and 0.1% for Str. thermophilus in order to maintain the propagation of the lactic acid bacteria. When the drink type yoghurts added with 0.4%, 0.6%, 0.8% and 1.0% water extract of Schizandra chinensis were kept at 4$^{\circ}C$ for 15 days, it was showed that the number of lactic acid bacteria was not significantly changed during the storage. The viable cell counts of the drink type yoghurts by addition of 0.4∼l.0% of water extract of Schizandra chinensis were 1.13${\times}$10$\^$9/∼2.29${\times}$10$\^$9/ CFU/mL, and these bacterial counts were still more than the legal standard(1.0${\times}$10$\^$8/ CFU/mL) even at 15 days of storage.

Filtering Rate with Effect of Water Temperature and Size of Two Farming Ascidians Styela clava and S. plicata, and a Farming Mussel Mytilus edulis (수온과 개체크기에 따른 양식산 미더덕, 흰멍게, 진주담치의 여수율)

  • KIM Yong Sool;Moon Tae Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.2
    • /
    • pp.272-277
    • /
    • 1998
  • Filtering rates of two farming ascidians Styela clava and S. plicata, and of a farming mussel Mytilus edulis were experimentally investigated with reference to effects of water temperature and size. Absorptiometric determinations of filtering rates were carried out in a closed system with experimental animals being decreased indicate dyes neutral red. Optical density (OD) of 440 nm in path length 22 mm cell used as the indication of food particles absorption was appeared directly in proportion with the concentration of neutral red dyes. The filtering rate F is calculated by Kim's equation $F\;=\;V(1-e^{-z})$, where V is the water volume ($\ell$) in the experimental jar, and Z is the decreasing coefficient of OD as meaning of instantaneous removal speed as In $C_t\;=\;In\;C_{o}-Z{\cdot}t$, in this formula $C_t$ is OD at the time t. Filtering rate of S. clava increased as exponential function with increasing temperature while not over critical limit, and the critical temperature for filtering rate was assumed to be between $28^{\circ}C$ and $29^{\circ}C$. In case of S. plicata, the critical temperature was to be below $13^{\circ}C$, and through the temperature range $15\~25^{\circ}C$ appeared a little difference in level even though with significant. M. edulis was not appear any significant effects by water temperature less than $29^{\circ}C$. The model formula derived from the results is as below, where F is filtering rate (${\ell}/hr/animal$), T is water temperature ($^{\circ}C$), and DW is dry meat weight (g) of experimental animal. $$S.\;Clava;\;F\;=\;e xp\;(0.119\;T-4.540)\;(DW)^{0.6745},\;T<29^{\circ}C$$) $$S.\;plicata;\;F\;=\;e xp\;(A_t)\;(DW)^{0.5675},\;(13^{\circ}C $$[A_t =-8.56+0.6805\;T-0.0153\;T^2]$$ $$M.\;edulis;\;F\;=\;0.3844\;(DW)^{0.4952},\;<29^{\circ}C$$)

  • PDF

Kinetic Studies of Lactic Acid Fermentation (Part 3) Effect of Phenol Derivatives on Fermentation (유산균발효에 관한 동력학적 연구 (제3보) 발효에 미치는 Phenol 유도체의 영향)

  • LEE Keun-Tai;YANG Hyeun-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.212-216
    • /
    • 1981
  • The growth of Lactobacillus bulgaricus treated with vanillin, ortho-vanillin and guaiaco1 was studied on synthetic medium in mechanically agitated chemostat culture, The exponential-phase growth rate exhibited a maximum at the cells treated with 50 ppm vanillin. That stimulation, however, appears to be an effect on growth rate rather than total cell growth. And the others were inhibited by the chemicals. Much greater inhibition in growth of the cells treated with 100 ppm of each chemical than oars treated with 50 ppm was observed after 25 hour fomentation. For aerobic microbes, the alcohol dehydrogenase reaction is enhanced for the reproduction of NAD, which consequently cause to stimulate fermentation. For micro-aerophilic microbes , however, the same effect was not observed at the present study at least in the case of cell concentration. However except f or one treated with 50 ppm vanillin the same effect was observed in the case of growth is to. From the result using the glucose as a substrate, it was found that the cell concentrations measured in terms of ultimate optical density (UOB/ml), were 0.96 and 0.92, when treated with 50 and 100 ppm vanillin; 0.40 and 0.45 when treated with ortho-vanillin 50 and 100 ppm: 0.49 and 0.47, when treated with guaiacol 50 and 100 ppm. The specific growth rates were 0.44, 0.15, 0.25, 0.29, 0.37, and 0.34; the specific production rates wire 0.33, 0.15, 0.16, 0.22, 0.28, and 0.26 and the glucose concentrations (g/1) after 25 hour fermentation were 23.5, 32.8, 31.5, 29.5, 28.0 and 28.8, these all in the same sequences as the first.

  • PDF

EVALUATION OF PERIODONTAL LIGAMENT CELL VIABILITY IN RAT TEETH ACCORDING TO VARIOUS EXTRA-ORAL DRY STORAGE TIMES USING MTT ASSAY (구강 외 노출시간에 따른 흰쥐 치아 치주인대세포 활성도의 MTT 검색법을 이용한 평가)

  • Jeon, In-Soo;Kim, Eui-Seong;Kim, Jin;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.398-408
    • /
    • 2006
  • The purpose of this study was to verify the usefulness of MTT analysis as a tool of measurement of the periodontal ligament cell viability from the extracted rat molar. A total of 80 Sprague-Dawley white female rat of 4 week-old with a body weight of 100 grams were used. The maxillary left and right, first and second molars were extracted under Ketamine anesthesia. Twenty-four teeth of each group (divided as five groups depending upon the time-lapse after extraction such as Immediate, 10, 20, 40 and 60 minutes) were immersed in $200{\mu}l$ of MTT solution (0.5 mg/ml) and processed for optical density measurements. Another 10 teeth of each group were treated as same as above and sectioned at $10{\mu}m$ for microscopic examination. All measurements values were divided by the value of hematoxylin-eosin staining which represented the volume of each corresponding samples. Immediate and 10 minute groups showed highest MTT values followed by 20, 40, and 60 minutes consecutively. Statistical significance (p<0.05) existed between all groups except in immediate versus 10 minute groups and 40 versus 60 minutes. Histological findings also showed similar findings with MTT results in crystal shape and crystal numbers between the experimental groups. These data indicate that in vivo MTT analysis nay be of value for evaluation of the periodontal ligament cell viability without time- consuming cell culturing processes.

EFFECT OF UNREACTED RESIN MONOMES ON THE ATIVITY OF CARIOGENIC BACTERIA (미반응 레진단량체가 우식유발성 세균의 활성에 미치는 영향)

  • Park, Seung-Kyu;Kim, Hwa-Sook;You, So-Young;Han, Jin-Ju;Kook, Joong-Ki;Lee, Nan-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.684-695
    • /
    • 2003
  • The aim of this study was to investigate the effect of composite resin components on proliferation and glucan synthesis by cariogenic bacteria, Streptococcus mutans and Streptococcus sobrinus. Light curing pit and fissure sealant was chosen for evluation. Specimens were eluted in deionized water for 10 minutes, 1, 12, and 24 hours. Extracts of specimens were diluted into 1/2, 1/4, and 1/8 with addition of BHI broth and BHI-YS. Bacteria were cultured in media included eluted components, and measured optical density($A_{600}$). The following results were obtained 1. 1/4 concentration of elutes for 10 minutes significantly inhibited the proliferation of S. mutans, whereas 1/2, 1/8 concentration of elutes stimulated it. Also, exacts, especially 1/2, 1/4 concentration, for 1 hours stimulated it. But exacts for 12, 24 hours had not effects on the proliferation of S. mutans. 2. 1/4 concentration of elutes for 10 minutes inhibited growth of S. sobrinus, whereas extracts for 1, 12, 24 hours had not effects on the proliferation of S. sobrinuss. 3. Extracts from composite resin stimulated total growth of S. mutans more than growth control group, where as inhibited it of S. sobrinus. 4. Extracts from composite resin, especially 1/4 concentration of it for 10 minutes increased the formation of water insoluble glucan of S. mutans. But elutes for 1, 12, 24 hours, and 1/8 concentration of it for 10 minutes inhibited it. 5. Except 1/4 concentration of elutes for 10 minutes, extracts decreased the formation of water insoluble glucan of S. sobrinus. 6. Total amount of formated glucan was 3-fold higher in S. mutans than in S. sobrinus.

  • PDF

EVALUATION OF THE VIABILITY OF PERIODONTAL LIGAMENT CELL IN RAT TEETH USING SLOW CRYOPRESERVATION METHOD WITH MAGNETIC FIELD (자기장 저속 냉동보관법을 이용한 쥐 치아 치주인대세포의 활성도 검사)

  • Ahn, Hyun-Jung;Kim, Eui-Seong;Kim, Jin;Kim, Duck-Won;Kim, Ki-Yeol;Lee, Chan-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.332-340
    • /
    • 2008
  • The purpose of this study was to evaluate the viability of periodontal ligament cell in rat teeth using slow cryopreservation method with magnetic field through MTT assay and TUNEL test. For each group, 12 teeth of 4 weeks old white female Sprague-Dawley rat were used for MTT assay, and 6 teeth in TUNEL test. The Maxillary left and right, first and second molars were extracted as atraumatically as possible under tiletamine anesthesia. The experimental groups were group1 (immediately extraction), group 2 (cold preservation at 4$^{\circ}C$ for 1 week), group 3 (rapid cryopreservation in liquid nitrogen), group 4 (slow cryopreservation with magnetic field of 1 G), and group 5 (slow cryopreservation). F medium was used as preservation medium and 10% DMSO as cryoprotectant. After preservation and thawing, the MTT assay and TUNEL test were processed. One way ANOVA and Scheffe method were performed at the 95% level of confidence. The value of optical density obtained after MTT analysis was divided by the value of eosin staining for tissue volume standardization. In both MTT assay and TUNEL test, it had showed no significant difference among group 3, 4, and 5. And group 3 had showed higher viability of periodontal ligament cell than group 2. From this study, slow cryopreservation method with magnetic field can be used as one of cryopreservation methods.

THE EFFICACY OF PROGRAMMED CRYO-PRESERVATION UNDER PRESSURE IN RAT PERIODONTAL LIGAMENT CELLS (압력 저속 냉동 방법의 쥐 치아 치주인대세포 보존 효율 평가)

  • Lee, Young-Eun;Kim, Eui-Seong;Kim, Jin;Han, Seung-Hoon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.356-363
    • /
    • 2009
  • The purpose of this study was to evaluate the viability of periodontal ligament cells in rat teeth using slow cryo-preservation method under pressure by means of MTT assay and WST-1 assay. Eighteen teeth of Sprague-Dawley white female rats of 4 week-old were used for each group. Both sides of the first and second maxillary molars were extracted as atraumatically as possible under Tiletamine anesthesia. The experimental groups were group 1 (Immediate control), group 2 (Cold preservation at $4^{\circ}C$for 1 week), group 3 (Slow freezing), group 4 (Slow freezing under pressure of 3 MPa). F-medium and 10% DMSO were used as preservation medium and cryo-protectant. For cryo-preservation groups, thawing was performed in $37^{\circ}C$water bath, then MTT assay and WST-1 assay were processed. One way ANOVA and Tukey method were performed at the 95% level of confidence. The values of optical density obtained by MTT assay and WST-1 were divided by the values of eosin staining for tissue volume standardization. In both MTT and WST-1 assay, group 4 showed significantly higher viability of periodontal ligament cells than group 2 and 3 (p < 0.05), but showed lower viability than immediate control group. By the results of this study, slow cryo-preservation method under pressure suggests the possibility for long term cryo-preservation of the teeth.

Enzymatic Method for Measuring ATP Related Compounds in Fish Sauces (효소법에 의한 액젓중의 ATP 관련물질 측정)

  • CHO Young Je;IM Yeong Sun;KIM Sang Moo;CHOI Young Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.4
    • /
    • pp.385-390
    • /
    • 1999
  • HPLC method usually has been used for the determination of ATP and its related compounds in fish muscle and fish sauce. But, total amount of ATP related compounds in fish sauce is determined less than that of fish muscle. In order to establish the extract analysis method for ATP related compounds in fish sauce, a new enzymatic method was developed and compared with existing HPLC method. Fish sauce was extracted with chilled perchloric acid and neutralized to Ph 7.0 with potassium hydroxide solution, the extract was used as sample analyzed by HPLC as usual. On the other hand, for sample analyzed by enzymatic method, 1 ml extract solution was pipetted into test tube. To the tube, 0.5ml of mixed suspension adenosinedeaminase (4U), nucleosidephosphorylase (0.02U) and xanthineoxidase (0.03U) suspended in 2.0ml of 1/15 M sodium phosphate buffer solution pH 7.6 and 1.5ml deionized water wereadded for the decomposition of IMP, HxR and Hx to uric acid at $37^{\circ}C$ for 40 minutes. Total uric acid was determined by measuring optical density at 290nm. In HPLC method, salt decreased the total amount of ATP related compounds by $13.6\~16.2\%$ at $2.5\%$ concentration, but no effect in enzymatic method. IMP, HxR and Hx were detected at 254nm, while uric acid at only 290nm. The ratio of the total amount of ATP related compounds by HPLC method was about $45\%$ of that by enzymatic method in fish sauce. Form these results, enzymatic method is more accurate and simple than HPLC method for analysis of ATP related compounds in fish sauce.

  • PDF

Evaluation of Quality Characteristics of Korean and Chinese Frozen Chopped Garlic (국내산 및 중국산 냉동 다진 마늘의 품질 특성 평가)

  • Lee, Seul;Kim, Seokyoung;Hwang, Inguk;Yoo, Seonmi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.111-117
    • /
    • 2015
  • This study investigated quality characteristics of commercial frozen chopped garlic. We collected six kinds of commercial frozen chopped garlic, four of which were domestic and the remaining two made in China. The moisture contents and drip loss of domestic frozen chopped garlic were significantly lower than those of Chinese garlic. Drip loss was positively correlated with moisture content (r=0.918, P<0.01). Total pyruvate contents of frozen chopped garlic ranged from $118.69{\pm}5.97{\sim}224.81{\pm}9.92{\mu}mol/g$ in domestic garlic and $75.27{\pm}5.91{\sim}79.35{\pm}1.79{\mu}mol/g$ in Chinese garlic. Allicin contents of frozen chopped garlic ranged from $8.91{\pm}0.34{\sim}13.09{\pm}0.35mg/g$ in domestic garlic and $5.91{\pm}0.08{\sim}6.05{\pm}0.27mg/g$ in Chinese garlic. Total thiosulfinate content of commercial frozen chopped garlic ranged from $0.60{\pm}0.07{\sim}1.33{\pm}0.12$ optical density/g. Total thiosulfinate content of commercial frozen chopped garlic was positively correlated with allicin content (r=0.892, P<0.01). Flavor patterns of commercial frozen chopped garlic measured by an electronic nose showed no difference between domestic and Chinese garlics.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF