• 제목/요약/키워드: Optical application

검색결과 1,871건 처리시간 0.032초

Oxide perovskite crystals type ABCO4:application and growth

  • Pajaczkowska, A.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.258-292
    • /
    • 1996
  • In the last year great interest appears to YBCO thin films preparation on different substrate materials. Preparation of epitaxial film is a very difficult problem. There are many requirements to substrate materials that must be fullfilled. Main problems are lattice mismatch (misfit) and similarity of structure. From paper [1] or follows that difference in interatomic distances and angles of substrate and film is mire important problem than similarity of structure. In this work we present interatomic distances and angle relations between substrate materials belonging to ABCO4 group (where A-Sr or Ca, B-rare earth element, C-Al or Ga) of different orientations and YBCO thin films. There are many materials used as substrates for HTsC thin films. ABCO4 group of compounds is characterized by small dielectric constants (it is necessary for microwave applications of HTsC films), absence of twins and small misfit [2]. There most interesting compounds CaNdAlO4, SrLaAlO4 and SrLaGaO4 were investigated. All these compounds are of pseudo-perovskite structure with space group 14/mmm. This structure is very similar to structure of YBCO. SLG substrate has the lowest misfit (0.3%) and dielectric constant. For preparation of then films of substrates of this group of compound plane of <100> orientation are mainly used. Good quality films of <001> orientations are obtained [3]. In this case not only a-a misfit play role, but c-3b misfit is very important too. Sometimes, for preparation of thin films substrates of <001> and <110> orientations were manufactured [3]. Different misfits for different YBCO faces have been analyzed. It has been found that the mismatching factor for (100) face is very similar to that for (001) face so there is possibility of preparation of thin films on both orientations. SrLaAlO4(SLA) and SrLaGaO4(SLG) crystals of general formula ABCO4 have been grown by the Czochralski method. The quality of SLA and SLG crystals strongly depends on axial gradient of temperature and growth and rotation rates. High quality crystals were obtained at axial gradient of temperature near crystal-melt interface lower than 50℃/cm, growth rate 1-3 mm/h and the rotation rate changing from 10-20pm[4]. Strong anisotropy in morphology of SLA and SLG single crystals grown by the Czochralski method is clearly visible. On the basics of our considerations for ABCO4 type of the tetragonal crystals there can appear {001}, {101}, and {110} faces for ionic type model [5]. Morphology of these crystals depend on ionic-covalent character of bonding and crystal growth parameters. Point defects are observed in crystals and they are reflected in color changes (colorless, yellow, green). Point defects are detected in directions perpendicular to oxide planes and are connected with instability of oxygen position in lattice. To investigate facets formations crystals were doped with Cr3+, Er3+, Pr3+, Ba2+. Chromium greater size ion which is substituted for Al3+ clearly induces faceting. There appear easy {110} faces and SLA crystals crack even then the amount of Cr is below 0.3at.% SLG single crystals are not so sensitive to the content of chromium ions. It was also found that if {110} face appears at the beginning of growth process the crystal changes its color on the plane {110} but it happens only on the shoulder part. The projection of {110} face has a great amount of oxygen positions which can be easy defected. Pure and doped SLA and SLG crystals measured by EPR in the<110> direction show more intensive lines than in other directions which allows to suggest that the amount of oxygen defects on the {110} plane is higher. In order to find the origin of colors and their relation with the crystal stability, a set of SLA and SLG crystals were investigated using optical spectroscopy. The colored samples exhibit an absorption band stretching from the UV absorption edge of the crystal, from about 240 nm to about 550 m. In the case of colorless sample, the absorption spectrum consists of a relatively weak band in the UV region. The spectral position and intensities of absorption bands of SLA are typical for imperfection similar to color centers which may be created in most of oxide crystals by UV and X-radiation. It is pointed out that crystal growth process of polycomponent oxide crystals by Czochralski method depends on the preparation of melt and its stoichiometry, orientation of seed, gradient of temperature at crystal-melt interface, parameters of growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth. Growth parameters have an influence on the morphology of crystal-melt interface, type and concentration of defects.

  • PDF

고추 세균점무늬병에 대한 Bion-M의 방제 효과 (Controlling activity of Bion-M against bacterial spot caused by Xanthomonas euvesicatoria)

  • 김아형;연초롱;김주형;김흥태
    • 농약과학회지
    • /
    • 제16권2호
    • /
    • pp.171-177
    • /
    • 2012
  • 온실에서 6엽기까지 재배한 고추 유묘(품종: 왕대박)에 병원균을 접종하기 7일 전에 Bion-M을 농도별로 토양 관주 처리한 후에, 세균점무늬병균인 Xanthomonas euvesicatoria 1523의 현탁액을 고추 잎 뒷면에 분무접종하였다. 이 때 세균 현탁액의 흡광도는 0.5로 조절하였다. 무처리구에서는 75%의 발병도를 보였으며, Bion-M을 20 ${\mu}g\;mL^{-1}$의 농도로 관주처리한 처리구에서는 19%의 발병도를 보여 74.7%의 효과를 보였다. Bion-M의 처리 농도가 4.0과 0.8 ${\mu}g\;mL^{-1}$일 경우에는 49.3과 29.3%의 방제 효과를 보였다. Bion-M을 20 ${\mu}g\;mL^{-1}$로 관주처리하였을 때에는 병원균의 접종농도와 관계없이 병이 발생하지 않았지만, 고추 유묘의 잎 색이 황화되며 하위엽은 탈락하는 약해 증상이 관찰되었다. Bion-M을 4.0 ${\mu}g\;mL^{-1}$로 처리하였을 때, 낮은 병원균 접종구에서는 97.8%, 높은 농도 접종구에서는 86.0%의 우수한 효과를 얻었다. 하지만 4.0 ${\mu}g\;mL^{-1}$의 처리구에서도 유묘의 생육이 저해되는 약해증상이 관찰되었다. 고추 성체에 병원균을 접종하기 2일 전과 7일 전에 Bion-M을 관주처리한 경우, 2일 전보다 7일전 처리에서 우수한 효과를 얻을 수 있었다. 2011년 충북 청주시 포장에서 Bion-M의 방제 효과를 조사하기 위하여 Bion-M을 7일 간격으로 3회 경엽 및 토양관주 처리하고 병발생 정도를 발병엽율로 조사하였을 때, Bion-M의 경엽과 토양관주처리 효과는 각각 24.0%와 58.4%이었지만, 발병도를 조사하였을 경우에는 58.8%와 71.2%로 나타났다. 이상의 결과를 통해서 Bion-M을 토양에 관주처리하였을 경우, 고추 세균점무늬병에 대한 방제 효과가 인정되었다.

항체검출 ELISA 적용을 위한 능성어 IgM의 안정성 및 특이 항체 반응 평가 (Evaluation of the stability of IgM and specific antibody response of sevenband grouper Epinephelus septemfasciatus for application of antibody-detection ELISA)

  • 김춘섭;장민석;김위식;김종오;김두운;김도형;한현자;정성주;오명주
    • 한국어병학회지
    • /
    • 제22권3호
    • /
    • pp.335-342
    • /
    • 2009
  • 본 연구에서는 능성어를 대상으로 항체 검출 ELISA법을 적용하기 위한 기초 연구로서 능성어 혈청의 보존 조건에 따른 IgM의 안정성을 검토하였으며, 또한 항체 검출 ELISA법을 통해 능성어의 특이 항체반응을 조사하였다. 항 BSA 능성어 혈청을 사용하여 보존 온도 (-80, -20 및 4${^{\circ}C}$) 및 기간 (1, 34, 61 및 119일)에 따른 ELISA값을 비교한 결과, 모든 시료에 서 뚜렷한 O.D.값의 차이는 확인되지 않았다. -80${^{\circ}C}$ 및 -20${^{\circ}C}$에 보존된 혈청을 사용하여 해동 횟수 (1, 5, 10회)에 따른 ELISA O.D.값을 비교한 결과, 해동을 반복한 혈청 및 미동결 혈청의 O.D.값은 뚜렷한 차이를 보이지 않았다. 이상의 결과로 능성어 혈청은 -80, -20 및 4${^{\circ}C}$에서 119일간 보존하거나 10회 반복 해동하여도 능성어 IgM의 안정함이 확인되었다. 사육수온에 따른 능성어의 특이적 항체 반응을 조사한 결과, 20${^{\circ}C}$에서 사육중인 능성어에서 는 BSA 면역 후 14일째부터 BSA에 대한 특이 항체가 확인되었고, 21일-28일에 가장 높은 항체가를 나타냈으며 그 후 항체가는 서서히 떨어졌으나 면역 70일째에도 BSA에 대한 특이 항체는 관찰되었다. 반면 25${^{\circ}C}$에서 사육중인 능성어에서는 7일째부터 항체가가 확인되었고, 14일-21일 가장 높은 항체가를 나타냈으며 그 후 항체가는 서서히 떨어져 면역 70일째에는 0.4-1.6의 O.D. 값이 관찰되었다. 이상의 결과로 능성어의 특이 항체 반응은 20${^{\circ}C}$보다 25${^{\circ}C}$에서 항체 형성이 빠르고 항체가도 높게 나타나는 것이 확인되었으며, 또한 20${^{\circ}C}$와 25${^{\circ}C}$에서 사육중인 능성어에서 특이 항체반응은 약 2달간 지속됨이 확인되었다.

In-Sb-Te 박막의 결정화 거동에 관한 투과전자현미경 연구 (A Transmission Electron Microscopy Study on the Crystallization Behavior of In-Sb-Te Thin Films)

  • 김청수;김은태;이정용;김용태
    • Applied Microscopy
    • /
    • 제38권4호
    • /
    • pp.279-284
    • /
    • 2008
  • 상변화 메모리 재료로 사용 가능한 In-Sb-Te (IST) 박막을 RF 마그네트론 스퍼터링법을 사용하여 증착한 후 열처리를 통해 온도에 따른 결정화 거동 및 미세구조를 투과전자현미경(TEM)을 통해 분석하였다. IST 박막은 as-dep 상태에서 비정질상으로 존재하였으며, 열처리 온도에 따라 결정상인 InSb, $In_3SbTe_2$, InTe으로 상변화가 일어났다. 이러한 상변화는 기존의 삼원계 상태도와 다른 비평형 상태에서의 상변태가 이루어짐을 확인할 수 있다. 상변화 과정 중 박막의 두께가 무질서하게 배열되었던 비정질상에서 규칙적인 배열을 갖는 결정질상으로 변할수록 감소하는 경향을 확인하였다. 또한 각각의 결정립의 크기도 온도가 증가할수록 증가하는 것을 관찰하였다. 특히, $350^{\circ}C$ 열처리한 박막의 InSb 상은 비정질 상태에서 표면에너지가 가장 낮은 {111}면을 따라 facet을 이루며 결정화가 이루어졌다. 온도가 증가함에 따라 $In_3SbTe_2$로 상변화가 일어났는데, $400^{\circ}C$ 열처리한 시편의 경우 미소영역에서 마이크로 트윈들이 관찰되었다. 이 면결함은 {111}면을 따라 양쪽의 격자점들이 일치하는 정합 쌍정립계를 이루고 있었으며, $450^{\circ}C$에서 동일영역을 관찰해 본 결과 쌍정 결함들이 치유되어 {111} facet 면을 이루고 있는 것을 확인하였다. 또한 비교적 작은 영역에서 상분리가 일어난 InTe 상도 관찰하였다. InTe 상의 경우 포정반응 온도인 $555^{\circ}C$보다 낮은 온도에서 관찰되었는데, InTe의 (002)면과 $In_3SbTe_2$의 (111)면이 비슷한 면간거리를 가지고 있음을 확인하였다. 추가적으로 $500^{\circ}C$ 이상의 온도에서 이들의 결정학적 관계에 따른 상변화 과정에 연구가 수행되어야 할 것으로 생각된다.

타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화 (THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS)

  • 황윤태;이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

복합레진의 광중합 전·후와 shade guide의 색차 비교 (COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES)

  • 전이주;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

볼록렌즈가 상을 만드는 원리에 대한 과학적 모형의 사회적 구성 프로그램 개발 및 적용 (Development and Application of Scientific Model Co-construction Program about Image Formation by Convex Lens)

  • 박정우
    • 한국광학회지
    • /
    • 제28권5호
    • /
    • pp.203-212
    • /
    • 2017
  • 과학적 모형은 특정한 물리적 현상을 기술, 설명, 예측할 수 있는 개념 체계를 말한다. 과학적 모형의 사회적 구성 수업은 과학교육 분야에서 새로운 교수 학습 전략으로 주목받고 있으며 다양한 연구가 진행되고 있다. 모형을 통한 예상과 실제 세계에서 얻은 자료와의 일치, 불일치에 따라 모형의 적합성을 판단하고 모형을 수정해 가는 것이 모형 구성 수업의 핵심이다. 하지만 많은 모형 구성 수업에서는 교사가 제공한 제한적인 자료를 가지고 모형을 비교하고 판단하는 것에 그쳤으며, 스스로 실험을 통해 얻은 실제 세계에 대한 자료를 가지고 모형의 적합성을 판단할 수 있는 기회를 제공하는 수업은 많지 않았다. 이에 본 연구에서는 실험을 통해 얻은 결과를 모형을 통한 예측과 직접 비교하여 모형을 평가할 수 있는 과학적 모형의 사회적 구성 프로그램을 제시하고자 하였다. 6개월간 교사, 연구자 간의 협력적 논의를 통해 중학교 2학년 빛과 파동 단원 중 '볼록렌즈가 상을 만드는 원리'라는 주제에 대해 총 5차시의 모형 구성 프로그램을 개발하였다. 경기도 남녀 공학 중학교 2학년 3개 반 80명의 일반 학생과 20년 경력의 현직 과학 교사가 2주간 개발된 프로그램에 함께 참여하였으며, 학생들에게 수업의 어떤 점이 좋거나 어려웠는지, 이 수업을 친구에게 추천하고 싶은지를 질문하였다. 수업 후 95.8%의 학생이 구조 규칙을 사용한 모형 이상의 과학적 모형을 구성하였다. 학생들의 응답을 살펴보면 원리를 찾아내거나 친구들을 이해시키기가 어려웠지만 이론으로 이해하기 어려웠던 것을 실험을 통한 모형 수정 과정을 통해 이해하게 되었고, 학급 친구들끼리 경쟁자가 아닌 동반자가 된다는 점이 좋았다는 등의 응답이 나타났다. 참여 학생 중 92.5%가 본 프로그램을 보통이상으로 친구에게 추천하겠다고 응답하였다. 개발된 프로그램은 학교현장에 적용되어 학생의 모형 구성 능력 및 사회적 구성 능력의 향상에 기여할 것으로 기대한다.

유사물질 실험을 위한 자동화 현미경 실험 기기의 적용과 노캠퍼를 이용한 입자 성장 및 단순 전단 변형 실험의 예 (Application of Automated Microscopy Equipment for Rock Analog Material Experiments: Static Grain Growth and Simple Shear Deformation Experiments Using Norcamphor)

  • 하창수;김성실
    • 자원환경지질
    • /
    • 제54권2호
    • /
    • pp.233-245
    • /
    • 2021
  • 암석의 미세구조에 대한 많은 연구는 실제 암석 관찰 뿐만 아니라 다양한 실험 장비를 이용하여 미구조의 발달 과정과 그 메커니즘을 이해하기 위해 수행되어 왔다. 변성이나 변형 작용 중에 입자 성장이나 입도의 변화를 일으킬 수 있는 광물 군집 내 입자 경계 이동 작용은 주요한 재결정작용 메커니즘 중 하나이다. 특히, 변형 과정 중 나타날 수 있는 입자 경계 이동의 연속적 관찰은 암석 유사 실험을 이용하여 수행될 수 있었다. 이번 연구에서는 다양한 실험 방법 중 유사 물질을 이용한 입자 성장 및 변형 실험 방법에 대해 기존 방법을 개량할 수 있는 실험 장비의 개발과 이를 통한 효과적인 미구조 분석 방법을 제시하였다. 개발된 실험 장비는 유사 물질 실험이 가능한 변형 장치와 실체 현미경에 회전 조작이 가능한 편광판들을 장착하여 광학적 조작이 가능하도록 구성되었다. 이들 장치들은 마이크로 컨트롤러를 통해 온도 및 변형 속도 제어 및 실험 동안 관찰되는 미구조 변화를 연속적으로 촬영할 수 있도록 자동화하여 구성되었다. 또한 편광판 회전 조작을 통해 취득되고 합성된 디지털 이미지들은 보다 정확한 입자 경계를 구분하고 분석할 수 있게 해주었다. 실험 결과의 입도 및 형태와 같은 미구조 분석을 위해 선분 교점 측정 방법과 입자 경계 트레이싱 방식을 비교하여 적용하였다. 유사물질로써는 석영과 유사한 광학적 성질을 가지는 노캠퍼(Norcamphor, C7H10O)라는 물질을 사용하였다. 개발된 장비의 실효성을 검증하고자 노캠퍼를 이용한 정적 입자 성장 실험과 단순 전단 변형 실험 및 이에 대한 미구조 분석을 수행하였다. 정적 입자 성장 실험은 시간이 지남에 따라 입자 수의 감소와 입도가 증가하는 전형적인 입자 성장 작용의 특징과 온도에 따른 성장 곡선들의 명확한 차이를 보여주었다. 중온-저변형율 조건의 단순 전단 변형 실험 결과는 평균 입도의 큰 변화는 없었으나, 입자 형태에 대해 전단 변형이 증가함에 따라 전단력 방향에 수직한 방향에 대해 약 53°의 방향으로 신장률이 증가하는 변화를 보여주었다. 이러한 미구조의 발달과정은 주어진 실험 조건에서 변형에 의해 입자 내부의 소성 변형과 내부 회복 작용이 균형을 이루면서 진행된 것으로 해석된다. 개량화 및 자동화된 실험장치를 이용한 이들 입자 성장 작용 실험 및 변형 실험의 예는 유사물질 실험에서 목적하는 바와 같이 실험 과정 동안의 입자의 미구조 변화과정을 순차적으로 관찰할 수 있고, 전체 수행 과정동안 수동적 조작없이 효율적으로 실험을 진행할 수 있다는 장점을 보여주었다.

드론과 선박을 동시 활용한 내만에서의 GOCI-II 산출물 검증 (Validation of GOCI-II Products in an Inner Bay through Synchronous Usage of UAV and Ship-based Measurements)

  • 백승일;고수윤;임태홍;전기성;도영주;정유진;박소현;이용탁;김원국
    • 대한원격탐사학회지
    • /
    • 제38권5_1호
    • /
    • pp.609-625
    • /
    • 2022
  • 위성산출물의 검증은 위성자료를 이용하게 되는 후속 분석작업에 결정적인 영향을 미친다. 특히, 탁하고 얕은 수심의 육상 인근 해역에서의 해색산출물은 해수구성입자 분포의 복잡성으로 인하여 오랫동안 그 성능 개선이 이루어지지 않고 있어왔다. 또한, 선박이나 고정관측소를 이용한 검증은 위성산출물과 현저히 차이나는 공간범위로 인하여 명확한 한계점을 노출해왔었다. 본 연구는 우선 선박을 이용한 현장조사를 통해서 천리안해양위성2호(GOCI-II)의 주요 산출물인 원격탐사반사도, 엽록소농도, 총부유물농도, 용존유기물 등에 대한 검증을 수행하였다. 둘째로, 본 연구에서는 드론영상을 이용한 산출물 검증을 위한 초기분석결과를 제시하였다. 선박과 위성사이의 공간범위 차이를 메우기 위하여 각 선박 정점에서 드론에 탑재된 MicaSense RedEdge 카메라를 이용해 해수에 대한 다분광 영상을 획득하였다. 향후 드론을 이용한 위성산출물 검증에 활용되도록 드론 고도에 따른 해수복사휘도의 변화를 분석하였다. 제한된 숫자의 현장조사 자료 개수이지만, 검증결과, 555 nm 에서의 GOCI-II 원격탐사반사도는 약 30% 가량 과대추정 되는 것으로 나타났고, 엽록소농도 및 용존 유기물은 현장 측정값과의 상관도가 낮았다. 총부유물농도는 결정계수 약 0.6의 상관도를 나타내었고 약 20%의 불확도를 가지는 것으로 나타났다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF