• 제목/요약/키워드: Operator failure

검색결과 131건 처리시간 0.025초

Detection and Isolation Method for Operator Failure by Unknown Input Observer

  • Kim, Hwan-Seong;Kim, Seung-Min
    • 한국항해항만학회지
    • /
    • 제32권2호
    • /
    • pp.133-140
    • /
    • 2008
  • In this paper, a fault detection method for operator failures using the observation technique is proposed. The suggested algorithm is extended using the conventional sensor/actuator fault detection method. First, it is assumed that operator failure affects human work operations, as it is an external input signal. With this assumption, a human work model with operator failure is suggested. Second, an unknown input observer with proportional and integral gains is introduced. The characteristic of this observer of estimating an external signal without an exact input is shown, and the conditions for the detection of an operator failure are proposed. Finally, by simulating the container crane operations, it is verified that the observer can accurately detect an operator failure and estimate its magnitude from the given internal signal.

SENSITIVITY ANALYSIS IN FUZZY RELIABILITY ANALYSISA

  • Onisawa, Takehisa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.764-769
    • /
    • 1988
  • In this paper the failure possibility and the error possibility are used to represent reliability of a technical component and that of a human operator, respectively. The failure possibility and the error possibility are fuzzy sets on the interval [0,1]. In a man-machine system, reliability of the technical component and that of the human operator are usually affected by many factors, e.g., the environment in which a machine is operated, psychological stress of the human operator, etc. The possibility is derived from not only the failure or the error rate but also estimates of these factors. The fuzzy reasoning plays an important role in the derivation. The reliability analysis is performed by the use of the possibility obtained by the present method. Moreover this paper discusses the sensitivity analysis which evaluates what extent the change of the estimation of each factor has an influence on reliability of a man-machine system. The important factors to be ameliorated are shown through the sensitivity analysis.

  • PDF

The Evaluation of Accident Management Strategy Involving Operator Action

  • Kim, Jaewhan;Jaejoo Ha
    • Nuclear Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.368-374
    • /
    • 1997
  • This paper presents a new approach to the evaluation of an accident management strategy when an operator action is involved. This approach classifies the failure in implementing a given strategy into 4 possible mechanisms, and provides their corresponding quantification methods : 1) the failure to formulate correct intention by operators, 2) the failure to take an adequate action following a correct diagnosis, 3) the failure of a system operation following an adequate action, and 4) the failure due to a delayed action. The proposed method was applied to assess a cavity flooding strategy that uses containment spray system (CSS), and the result shows that the method is more appropriate in evaluating accident management strategies when human action is involved.

  • PDF

트랜잭션 로그 분석을 통한 웹기반 온라인목록의 검색행태 추이 분석 (Trends of Web-based OPAC Search Behavior via Transaction Log Analysis)

  • 이성숙
    • 한국비블리아학회지
    • /
    • 제23권2호
    • /
    • pp.209-233
    • /
    • 2012
  • 이 연구에서는 웹기반 온라인목록 이용자들의 전반적인 검색행태를 알아보기 위해, 7년 동안의 트랜잭션 로그를 분석하였다. 웹기반 온라인목록의 검색형태는 검색전략과 검색실패의 관점에서 조사하였다. 검색전략에서는 검색유형, 접근점, 연산자, 검색문의 길이, 단어 사용횟수, 웹기반 온라인목록 이용횟수, 시간대별 및 요일별 이용횟수를 분석하였다. 또한 검색실패는 검색실패율과 접근점별 검색실패율, 연산자별 검색실패율을 분석하였다. 이 연구결과는 향후 웹기반 온라인목록 시스템과 서비스 개선에 활용될 수 있을 것으로 기대된다.

A Systems Engineering Approach for CEDM Digital Twin to Support Operator Actions

  • Mousa, Mostafa Mohammed;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.16-26
    • /
    • 2020
  • Improving operator performance in complex and time-critical situations is critical to maintain plant safety and operability. These situations require quick detection, diagnosis, and mitigation actions to recover from the root cause of failure. One of the key challenges for operators in nuclear power plants is information management and following the control procedures and instructions. Nowadays Digital Twin technology can be used for analyzing and fast detection of failures and transient situations with the recommender system to provide the operator or maintenance engineer with recommended action to be carried out. Systems engineering approach (SE) is used in developing a digital twin for the CEDM system to support operator actions when there is a misalignment in the control element assembly group. Systems engineering is introduced for identifying the requirements, operational concept, and associated verification and validation steps required in the development process. The system developed by using a machine learning algorithm with a text mining technique to extract the required actions from limiting conditions for operations (LCO) or procedures that represent certain tasks.

화재 후 운전원수동조치(OMA) 정량화를 위한 화재 인간신뢰도분석 (HRA) 요소에 대한 고찰 (An Investigation of Fire Human Reliability Analysis (HRA) Factors for Quantification of Post-fire Operator Manual Actions (OMA))

  • 최선영;강대일;정용훈
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.72-78
    • /
    • 2023
  • The purpose of this paper is to derive a quantified approach for Operator Manual Actions (OMAs) based on the existing fire Human Reliability Analysis (HRA) methodology developed by the Korea Atomic Energy Research Institute (KAERI). The existing fire HRA method was reviewed, and supplementary considerations for OMA quantification were established through a comparative analysis with NUREG-1852 criteria and the review of the existing literature. The OMA quantification approach involves a timeline that considers the occurrence of Multiple Spurious Operations (MSOs) during a Main Control Room Abandonment (MCRA) determination and movement towards the Remote Shutdown Panel (RSP) in the event of a Main Control Room (MCR) fire. The derived failure probability of an OMA from the approach proposed in this paper is expected to enhance the understanding of its reliability. Therefore, it allows moving beyond the deterministic classification of "reliable" or "unreliable" in NUREG-1852. Also, in the event of a nuclear power plant fire where multiple OMAs are required within a critical time range, it is anticipated that the OMA failure probability could serve as a criterion for prioritizing OMAs and determining their order of importance.

ED-FEM multi-scale computation procedure for localized failure

  • Rukavina, Ivan;Ibrahimbegovic, Adnan;Do, Xuan Nam;Markovic, Damijan
    • Coupled systems mechanics
    • /
    • 제8권2호
    • /
    • pp.111-127
    • /
    • 2019
  • In this paper, we present a 2D multi-scale coupling computation procedure for localized failure. When modeling the behavior of a structure by a multi-scale method, the macro-scale is used to describe the homogenized response of the structure, and the micro-scale to describe the details of the behavior on the smaller scale of the material where some inelastic mechanisms, like damage or plasticity, can be defined. The micro-scale mesh is defined for each multi-scale element in a way to fit entirely inside it. The two scales are coupled by imposing the constraint on the displacement field over their interface. An embedded discontinuity is implemented in the macro-scale element to capture the softening behavior happening on the micro-scale. The computation is performed using the operator split solution procedure on both scales.

야전 치명고장자료를 이용한 함정전투체계 신뢰성 분석 및 활용 방안 (A Study of Reliability Analysis and Application on Naval Combat System Using Field Critical Failure Data)

  • 김영진;오현승;최봉완
    • 산업경영시스템학회지
    • /
    • 제39권4호
    • /
    • pp.49-59
    • /
    • 2016
  • Naval combat system developed in-country is progressing at an alarming rate since 2000. ROK navy will be achieved all vessels that have combat system in the near future. The importance of System Engineering and Integrated Logistics Support based on reliability analysis is increasing. However, reliability analysis that everyone trusted and recognized is not enough and applied practically for development of Defense Acquisition Program. In particular, Existing Reliability Analysis is focusing on reliability index (Mean Time Between Failure (MTBF) etc.) for policy decision of defense improvement project. Most of the weapon system acquisition process applying in the exponential distribution simply persist unreality due to memoryless property. Critical failures are more important than simple faults to ship's operator. There are no confirmed cases of reliability analysis involved with critical failure that naval ship scheduler and operator concerned sensitively. Therefore, this study is focusing on Mean Time To Critical Failure (MTTCF), reliability on specific time and Operational Readiness Float (ORF) requirements related to critical failure of Patrol Killer Guided missile (PKG) combat system that is beginning of naval combat system developed in-country. Methods of analysis is applied parametric and non-parametric statistical techniques. It is compared to the estimates and proposed applications. The result of study shows that parametric and non-parametric estimators should be applied differently depending on purpose of utilization based on test of normality. For the first time, this study is offering Reliability of ROK Naval combat system to stakeholders involved with defense improvement project. Decision makers of defense improvement project have to active support and effort in this area for improvement of System Engineering.

Variability of plant risk due to variable operator allowable time for aggressive cooldown initiation

  • Kim, Man Cheol;Han, Sang Hoon
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1307-1313
    • /
    • 2019
  • Recent analysis results with realistic assumptions provide the variability of operator allowable time for the initiation of aggressive cooldown under small break loss of coolant accident or steam generator tube rupture with total failure of high pressure safety injection. We investigated how plant risk may vary depending on the variability of operators' failure probability of timely initiation of aggressive cooldown. Using a probabilistic safety assessment model of a nuclear power plant, we showed that plant risks had a linear relation with the failure probability of aggressive cooldown and could be reduced by up to 10% as aggressive cooldown is more reliably performed. For individual accident management, we found that core damage potential could be gradually reduced by up to 40.49% and 63.84% after a small break loss of coolant accident or a steam generator tube rupture, respectively. Based on the importance of timely initiation of aggressive cooldown by main control room operators within the success criteria, implications for improvement of emergency operating procedures are discussed. We recommend conducting further detailed analyses of aggressive cooldown, commensurate with its importance in reducing risks in nuclear power plants.

PAR기법을 이용하여 유지보수 영향을 고려한 고장 데이터의 보정기법에 관한 연구 (A Study on Revision Method of Historical Fault Data Considering Maintenance Effect to Use Proportional Aging Reduction(PAR))

  • 추철민;김재철;문종필;이희태;박창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-11
    • /
    • 2006
  • This paper suggests a revision method for historical fault data using Proportional Aging Reduction(PAR) to consider maintenance effect in time-varying failure rate. In order to product time-varying failure rate, the historical fault data are necessary. However, the maintenance record could be left out in historical data by spot operator's mistake. In this case, the failure rate is produced less than the average failure rate for increasing equipments' life-time by maintenance effect. Hence, it is necessary for new time-varying failure rate to extract maintenance effect from the existing fault data. In this paper, the revision method to reduce equipments' life-time, adversely using PAR among three techniques to consider maintenance effect.

  • PDF