• 제목/요약/키워드: Operational mode

검색결과 440건 처리시간 0.027초

Operational modal analysis for Canton Tower

  • Niu, Yan;Kraemer, Peter;Fritzen, Claus-Peter
    • Smart Structures and Systems
    • /
    • 제10권4_5호
    • /
    • pp.393-410
    • /
    • 2012
  • The 610 m high Canton Tower (formerly named Guangzhou New Television Tower) is currently considered as a benchmark problem for structural health monitoring (SHM) of high-rise slender structures. In the benchmark study task I, a set of 24-hour ambient vibration measurement data has been available for the output-only system identification study. In this paper, the vector autoregressive models (ARV) method is adopted in the operational modal analysis (OMA) for this TV tower. The identified natural frequencies, damping ratios and mode shapes are presented and compared with the available results from some other research groups which used different methods, e.g., the data-driven stochastic subspace identification (SSI-DATA) method, the enhanced frequency domain decomposition (EFDD) algorithm, and an improved modal identification method based on NExT-ERA technique. Furthermore, the environmental effects on the estimated modal parameters are also discussed.

개념설계 단계의 잠수함 작전효과도 시뮬레이션 모델 연구 (A Study on the submarine operational effectiveness simulation model in the concept design phase)

  • 박준규
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.47-58
    • /
    • 2004
  • This paper focuses on the technical information about the development of the submarine operational effectiveness simulation model for the feasibility study stage of the submarine design. The simulation model is classified into simulation control model and system model. Using user input and related performance parameters, it can simulate various scenarios by no change of the program because it includes tactic manager which makes decision about every situation. And the Monte-Carlo simulation mode which provides the stochastic results is available. Through the test simulation, the usefulness of the simulation model was verified. It should be helpful for the analysis of the submarine operational effectiveness by diversified scenarios in the concept design phase..

Infill wall effects on the dynamic characteristics of RC frame systems via operational modal analysis

  • Komur, Mehmet A.;Kara, Mehmet E.;Deneme, Ibrahim O.
    • Structural Engineering and Mechanics
    • /
    • 제74권1호
    • /
    • pp.121-128
    • /
    • 2020
  • This paper presents an experimental study on the dynamic characteristics of infilled reinforced concrete (RC) frames. A 1/3-scaled, one-bay, three-storey RC frame was produced and tested by using operational modal analysis (OMA). The experiments were performed on five specimens: one reference frame with no infill walls and four frames with infill walls. The RC frame systems included infill walls made of hollow clay brick, which were constructed in four different patterns. The dynamic characteristics of the patterns, including the frequency, mode shapes and damping ratios in the in-plane direction, were obtained by 6 accelerometers. Twenty-minute records under ambient vibration were collected for each model, and the dynamic characteristics were determined using the ambient vibration testing and modal identification software (ARTeMIS). The experimental studies showed that the infill walls significantly affected the frequency value, rigidity and damping ratio of the RC frame system.

시뮬레이션을 통한 정류형 초전도 전류발생장치의 동작특성해석 (The Analysis of operational characteristic of superconducting current generator by computer simulation)

  • 추용;주민석;홍중배;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.95-97
    • /
    • 1995
  • A superconducting current generator, or a superconducting rectifier(SCR) is used as a current source to energize a superconducting magnets in SMES, MRI. We selected a full-wave SCR among various SCR models and analyzed its operational characteristics by computer simulation. In process of pumping the current, the improvement of performance is dependent on how much bigger the open resistance of the switch is in comparison to load coil impedance when one of two switches become active. Faster transfer can he seen in resistive commutation mode by shortening the time elapsed for the resistance to arrive at certain level from zero state. Although recovery time for the switch has no direct effect on current pumping, optimal switch design is needed to increasing operational frequency.

  • PDF

Stateflow를 이용한 소형제트기 Flight Director의 비행모드 구현 (Realization of Flight Modes for Light General Aviation Flight Director using Stateflow)

  • 이장호;김성필;성기정;김웅태
    • 항공우주시스템공학회지
    • /
    • 제1권2호
    • /
    • pp.6-12
    • /
    • 2007
  • Flight modes of automatic flight control system for light general aviation flight deck. Garmin G1000, were realized using Stateflow. In developing aircraft, it is difficult to verify the operational flight program in particular branch statement because developer can not see any visual logical steam. So, Stateflow has been used to visualize logical stream, transition from one flight mode to another flight mode. The performance was approved by applying flight mode transition conditions of G1000 to proposed transition system that is composed of states, switches, events, data and transition conditions. DURMI-II was used as 6-DOF simulation model.

  • PDF

Camera Controller in MSC(Multi-Spectral Camera)

  • Kim, Young-Sun;Yong, Sang-Soon;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1081-1083
    • /
    • 2003
  • The CC's main objective is to manage and control the various operation of the MSC camera. The CC has capability to control the various camera operation modes such as INIT mode, WAIT mode, STANDBY mode, READY IMAGING, DEFAULT READY IMAGING, IBIT and IMAGING mode as well as to manage the interface of the PMU. This paper also shows not only the design concepts in the both of the hardware and the operational software, but also the implementation results for the various CC functions.

  • PDF

Mode identifiability of a multi-span cable-stayed bridge utilizing stabilization diagram and singular values

  • Goi, Y.;Kim, C.W.
    • Smart Structures and Systems
    • /
    • 제17권3호
    • /
    • pp.391-411
    • /
    • 2016
  • This study investigates the mode identifiability of a multi-span cable-stayed bridge in terms of a benchmark study using stabilization diagrams of a system model identified using stochastic subspace identification (SSI). Cumulative contribution ratios (CCRs) estimated from singular values of system models under different wind conditions were also considered. Observations revealed that wind speed might influence the mode identifiability of a specific mode of a cable-stayed bridge. Moreover the cumulative contribution ratio showed that the time histories monitored during strong winds, such as those of a typhoon, can be modeled with less system order than under weak winds. The blind data Acc 1 and Acc 2 were categorized as data obtained under a typhoon. Blind data Acc 3 and Acc 4 were categorized as data obtained under wind conditions of critical wind speeds around 7.5 m/s. Finally, blind data Acc 5 and Acc 6 were categorized as data measured under weak wind conditions.

ODS를 이용한 대형종의 맥놀이 지도 작성법 (Beat Map Drawing Method for a Large Size Bell using ODS)

  • 박인석;이중혁;박선미;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.929-932
    • /
    • 2012
  • Beat map shows the distribution property of the beating sound in the bell structure. Using the beat map, beat control and beat estimation are available. To draw the beat map, mode pair parameters of the bell are required. However, in case of large bell which is struck by a heavy wooden hammer, it is very difficult to measure the excitation force and to obtain the mode pair parameters. In this paper, we determined the mode pair parameters of the bell from the transmissibility between the roving signal and reference signal, using ODS(operational deflection shape) method. The mode pair data are input to the theoretical model of the beat response and beating waves are generated on the bell circumference. All the numerical and beat map drawing procedures are automatized using Matlab. Finally, the reliability of the beat map generated by the program is verified.

  • PDF

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.

초전도 영구전류스위치의 설계. 제작 및 특성시험 (The design, construction and operational characteristics of the superconducting persistent current switch)

  • 오윤상;이상진;최경달;류강식;고태국
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.193-198
    • /
    • 1996
  • Low power superconducting persistent current switch(PCS) for the superconducting magnet systems in the persistent mode was developed and its experimental results were analyzed when the system was charged or discharged. The multifilament NbTi wire with Cu matrix was used for the PCS. The constructed NbTi superconducting switch with superconducting magnet system operated successfully. It also operated on-off switching action with good stabilization. The maximum operating current in persistent mode was 60A (at 1T). In persistent current mode, the decay of the persistent current at 60A was observed. Its decay was 3.55% in 60 min. It is possible to make the persistent current switch with the better decaying of persistent current if some problems for joint resistance are solved.

  • PDF