• Title/Summary/Keyword: Operational Phase

Search Result 448, Processing Time 0.035 seconds

Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션)

  • Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성)

  • Lim, Sung-Hun;Han, Tae-Hee;Park, Hyoung-Min;Cho, Yong-Sun;Song, Jae-Joo;Choi, Myoung-Ho;Hwang, Jong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.112-113
    • /
    • 2006
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-$T_c$ superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

A Study on Target Operational Availability Setting for Warship based on OMS/MP and Similar Warship RAM Analysis (함정 OMS/MP 및 유사체계 RAM분석 활용 기반 목표운용가용도 설정 연구)

  • Ha, Sungchul;Kim, Kyoungyong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.651-659
    • /
    • 2012
  • Target operational availability setting is the first step to setting up a goal which a weapon system development project have to achieve and doing RAM analysis during whole life of a weapon system. It is important as a key factor to doing RAM analysis in the early phase of weapon system development. This paper present a methodology to set a target operational availability for, especially, a warship when it develop. This methodology uses Operational Mode Summary/Mission Profile(OMS/MP) of the developing warship and RAM analysis results of similar warships to calculate wartime and peacetime target operational availability. It will be used in early phase of not only warship development but also army or aircraft weapon systems when these develop.

Effect of operational pH on anaerobic hydrogen fermentation of food waste (음식폐기물의 혐기성 수소 발효시 운전 pH의 영향)

  • Lee, Chae-Young;Lee, Se-Wook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.3
    • /
    • pp.73-78
    • /
    • 2011
  • The pH is one of the most important factors affecting metabolism pathway and activity of hydrogen producing bacteria. The effect of operational pH on anaerobic hydrogen fermentation of food waste was evaluated at mesophilic condition. In this batch experiment, the initial pH was 8.0 and the operational pH was controlled at 4.7~7.0 by the addition of 5N KOH solutions. At the operational pH of 4.7, the lag phase and the maximum hydrogen production were 47.9h and 534.4 mL, respectively. The lag phase and the maximum hydrogen production were decreased as the operational pH increased. At the operational pH of 7.0, the lag phase and the maximum hydrogen production were 4.2 h and 213.8 mL, respectively.

An Exploratory Study on the Information Technology Outsourcing Risk Factors: An IPO Perspective (IPO 관점에서의 정보기술 아웃소싱 위험요인에 관한 탐색적 연구)

  • Yang Kyung sik;Kim Hyun soo
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.3
    • /
    • pp.35-62
    • /
    • 2004
  • Recently, IT outsouricng has been one of the major concerns of many companies. This paper explores the relationship between information technology outsourcing risk factors and outsourcing performance. It is based upon a three-phase process utilizing IPO (Input-Process-Output) system. The first phase means the outsourcing planning risks t~at arise from overall environment of outsourcing, organizational refuse, and wrong contracts. The second phase implies outsourcing operational risks, which are occurred while out-sourcing perform and consist of organizational acceptances of outsourcing, partnership and hidden costs. The last phase is outsourcing performance based on four perspective of BSC(Blanced Scored Card). The survey was performed on the IT/IS firms, and the data was collected from 53 service receivers. The result of the analysis are as follows. First, Outsourcing planning risks positively affects the operational risks. Second, Outsourcing operational risks negatively affects the Outsourcing Performance.

  • PDF

Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL (삼상 분리형 자속구속형 전류제한기의 동작 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Park, Chung-Ryul;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

A Study on the S/W Reliability Comparison during Operational Stage (운영중 소프트웨어의 고장률에 의한 신뢰도 비교 연구)

  • Che Gyu-Shik;Moon Myung-Ho;Jeon In-Oh
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.2
    • /
    • pp.17-28
    • /
    • 2006
  • The SRGM has been studied under the assumption that S/W reliability can grow as the fault causing failure is removed even during operational phase because the debugging is available. On the other hand, some papers insist on the uniform failure rate during operational phase because the debugging may not be available in case of universal software. The phenomenon, however, has been observed informally many times that the products S/W reliability grows as the time goes by even without any debugging in point of customer view. I propose the simple approaching method to model the S/W reliability phenomenon that the failure rate reduces as time goes on without modifying the existing reliability model in this paper.

  • PDF

Study on ALDT Optimal Setting Considering Retention Level of Repair Items (수리품목 보유수준을 고려한 ALDT 최적화 설정방안 연구)

  • Jun, Joon-Hyung;Hwang, Kyoung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.269-275
    • /
    • 2020
  • RAM of elements to support weapon systems is conducted at the initial development phase and standard is suggested to accomplish strategy requirement performance from a design spec. Operational availability is a key point of the military's ability to ensure combat readiness and to win the battle. In the weapon system development phase, operational availability is used as a development standard. The military provides ALDT, operation and standby time, which are elements of operational availability. ALDT is a key element of operational availability that must be maintained for combat readiness, as it depends on the aging of a weapon system, maintenance policies and geographical conditions. Operational Availability to be set at the development phase has many differences from the operational availability that is analyzed in the actual operational phase because ALDT is applied as a simple assumption. In the paper, we analyzed ALDT applying the decision tree method through failure data acquired from initial operation. Through this study, we have devised the optimal ALDT setting method to achieve operational availability about operation when the weapons system is unstable.

Development of Three Phase Optimal Power Flow for Distributed Generation Systems (분산전원계통을 위한 3상 최적조류계산 프로그램 개발)

  • Song, Hwa-Chang;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.882-889
    • /
    • 2010
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow (3POPF). 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique for 3POPF, this paper adopts a simulation-based method of particle swarm optimization (PSO). In the PSO based 3POPF, a utility function needs to be defined for evaluation of the degree in operational improvement of each particle's current position. To evaluate the utility function, in this paper, NR-based 3 phase power flow algorithm was developed which can deal with looped distributed generation systems. In this paper, illustrative examples with a 5-bus and a modified IEEE 37-bus test systems are given.