• 제목/요약/키워드: Operational Effectiveness

검색결과 492건 처리시간 0.032초

HMS 운용방안에 관한 연구 (A Study on Operational Method of a HMS)

  • 신성철;이철목
    • 한국군사과학기술학회지
    • /
    • 제15권5호
    • /
    • pp.586-593
    • /
    • 2012
  • The Navy is in the process of developing a sonar-operation strategy to increase the effectiveness of underwater target searching capability. HMS is the basic strategy to detect underwater targets. The advantages of HMS is that, it has a short preparation time to operate and can be always used regardless of sea conditions and weather. However, it is difficult to effectively detect underwater targets due to the interaction between marine environments and sonar-operations. During the research, the effectiveness of the HMS system's underwater target searching capability was analyzed by integrating various search and defense patterns, and environment conditions into the simulation. In the simulation the ship search an evasive target within a set region. The simulation presented results for an effective searching and defense methods of underwater targets. These research results can be used as foundation for advancing and improving the sonar operational tactics.

C2모델 기반 전장아키텍처의 전투효과 평가방안 (A Study on Evaluation of Combat Effectiveness in WMA-EA based on C2 Model)

  • 박양수;정찬기
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.619-626
    • /
    • 2010
  • ROK Joint Chiefs of Staff in developing an WMA-EA(Warfighting Mission Area-Enterprise Architecture) tries to create the practical buildup requirements of military power through precise requirements and operational capabilities based on the architectures. However, it is difficult to verify the effectiveness of target architectures and do efficient requirement planning because we cannot know the gap of quantitative combat effectiveness between current and target WMA-EAs. This study presents an evaluation method of combat effectiveness and focuses on combat's positive effects in WMA-EAs. The method proposed is based on C2 model which is appropriate for the evaluation of combat effectiveness in architectures. We verify the effectiveness of the proposed method through a case study of an anti-ship warfare architecture.

An Active-Only Voltage-Mode Integrator and Its Applications

  • Shinji, Ohyama;Kim, Doh-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.158.4-158
    • /
    • 2001
  • This paper presents a novel circuit configuration for realizing the continuous-time active-only voltage-mode integrator. The proposed integrator consists only of internally compensated type operational amplifier (OA) and operational transconductance amplifiers (OTAs). Since no external passive elements are required, the integrator is suitable for integrated circuit implementation in either bipolar or CMOS technologies. Moreover, the integrator gain can be electronically tuned by adjusting the bias currents of the OTAs. The characteristics of the proposed integrator and the effectiveness of the design procedure in realizing various analog transfer functions have been examined by PSPICE simulation.

  • PDF

고정형 선배열 음탐기 체계를 위한 효과도 분석 기법 연구 (Study on the Effectiveness Analysis Method for the Fixed Linear Arrays System)

  • 김정훈
    • 한국군사과학기술학회지
    • /
    • 제7권2호
    • /
    • pp.32-40
    • /
    • 2004
  • In this paper, a simulation model for FLAS(Fixed Linear Arrays System) is presented and methods for effectiveness analysis are studied to analyze the valid target detection effectiveness of this system. The simulation model is constructed taking the FLAS operational specification into account, and thus the change in system specification is effectively reflected on the simulation results. The computational burden is reduced by using the pre-processed simulation parameters which are calculated from the real environmental database. Also, the cell effectiveness and TMOE(Total Measurement of Effectiveness) are computed. The target detection effectiveness of FLAS can be simulated under the multiple target interference simulation. It is shown that the presented algorithm is suitable for the underwater system which needs the simulation model for the optimum system design.

Requirements Study of a High-Resolution Satellite Image Receiving, Processing and Archiving System

  • Hong, Min-Nyo;Kim, Tae-Jung;Kim, Tag-Gon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.19-24
    • /
    • 1999
  • This paper addresses a new project being carried out at Satellite Technology Research Center. The purpose of the project is to implement a system which receives, processes and stores 1m resolution satellite image transmitted at over 300Mbps down link data rates. In order to develop such a system, a system operational concept design and a requirements study were being carried out As a result of the operational concept design, system objectives, system context and system functions were defined. The system shall be operated according to the philosophy of maximum automation. rapid processing, reliability, integrity, cost effectiveness, and expandability. The system is divided into twelve independent processes and its behavior is modeled by operational scenario, which are combinations of independent processes. Process information and logs generated by the system shall be stored in databases and data received and generated be automatically archived and managed in a hierarchical storage device. The system shall have redundant components in order to be ready for recovering from sudden system failures. This paper will describe in detail the system operational concept design and the system requirements derived from the operational concept design.

  • PDF

DC Microgrid Operational Method for Enhanced Service Reliability Using DC Bus Signaling

  • Hwang, Pyeong-Ik;Jang, Gilsoo;Pyo, Gi-Chan;Han, Byung-Moon;Moon, Seung-Il;Ahn, Seon-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.452-464
    • /
    • 2015
  • This paper proposes a DC microgrid operational strategy and control method for improved service reliability. The objective is to supply power to as many non-critical loads as possible, while providing an uninterrupted power supply to critical loads. The DC bus signaling method, in which DC voltage is an information carrier, is employed to implement the operational strategy in a decentralized manner. During grid-connected operation, a grid-tied converter balances the power of the microgrid by controlling the DC voltage. All loads are connected to the microgrid, and operate normally. During islanded operation, distributed generators (DGs), a backup generator, or an energy storage system balances the power. However, some non-critical loads may be disconnected from the microgrid to ensure the uninterrupted power supply to critical loads. For enhanced service reliability, disconnected loads can be automatically reconnected if certain conditions are satisfied. Control rules are proposed for all devices, and detailed microgrid operational modes and transition conditions are then discussed. Additionally, methods to determine control parameter settings are proposed. PSCAD/EMTDC simulation results demonstrate the performance and effectiveness of the proposed operational strategy and control method.

지휘소 작전지속성 보장을 위한 도파관의 전자기파 차폐성능 향상방안 (Assessment of the Electromagnetic Pulse Shield Effectiveness of the Wave-guided Below Cutoff Filled with Water and Oil for Guaranteeing the Operational Sustainment of the Command Post)

  • 윤상호;손기영;김석봉;박영준
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.579-584
    • /
    • 2013
  • 유사시 군 지휘시설에서는 시설 외부로부터의 수자원 및 에너지자원 공급이 차단 혹은 제한된다. 따라서 방호시설 내부에는 작전기간 중 필요한 충분한 양의 수자원 및 에너지자원을 확보하고 있어야 한다. 하지만, 전쟁양상의 변화는 시설내부에서 최소 2주 이상의 작전지속성을 요구하고 있다. 이러한 요구로 인하여 유사시에도 시설 외부로부터 내부로의 수자원 및 에너지자원 공급이 불가피하게 되었다. 이에 본 연구에서는 유전체 자체의 EMP 차폐 성능에 착안하여, 작전지속성 보장을 위한 충분한 급수/급유가 가능한 도파관 설치를 위하여 도파관 직경 및 유전체 종류에 따른 EMP 방호성능을 실험적으로 분석하였다. 실험을 통해 다중 도파관을 통해 효과적인 EMP 차폐와 동시에 군 지휘시설 내부로의 안정적인 급수/급유가 가능함을 확인할 수 있었다.

Steady-state Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Xu, X.K.;Lam, B.P.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.161-167
    • /
    • 2003
  • This paper presents a study performed to investigate the steady-state operational strategies of UPFCs in the Jeollanam-Do system in Korea. The objective of the study was to determine the UPFC operating points under normal and contingency conditions. The study consists of developing load flow models to simulate different load levels with and without UPFCs in the system, assessing the effectiveness of UPFCs by contingency analysis, and introducing optimal corrective actions for removing voltage problems caused by contingencies. The paper describes analytical tools, models and approach. It also includes analysis and discussion of the study results. The paper contributes to the area of transmission operational studies with FACTS applications.

FRACTIONAL CHEBYSHEV FINITE DIFFERENCE METHOD FOR SOLVING THE FRACTIONAL BVPS

  • Khader, M.M.;Hendy, A.S.
    • Journal of applied mathematics & informatics
    • /
    • 제31권1_2호
    • /
    • pp.299-309
    • /
    • 2013
  • In this paper, we introduce a new numerical technique which we call fractional Chebyshev finite difference method (FChFD). The algorithm is based on a combination of the useful properties of Chebyshev polynomials approximation and finite difference method. We tested this technique to solve numerically fractional BVPs. The proposed technique is based on using matrix operator expressions which applies to the differential terms. The operational matrix method is derived in our approach in order to approximate the fractional derivatives. This operational matrix method can be regarded as a non-uniform finite difference scheme. The error bound for the fractional derivatives is introduced. The fractional derivatives are presented in terms of Caputo sense. The application of the method to fractional BVPs leads to algebraic systems which can be solved by an appropriate method. Several numerical examples are provided to confirm the accuracy and the effectiveness of the proposed method.