• 제목/요약/키워드: Operation voltage

검색결과 3,665건 처리시간 0.034초

유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계 (Design of New Current Full-Bridge Resonant Inverter for Induction Heating System)

  • 이상훈;임상길;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

다중 부하중심점에 기반한 온라인 퍼지 ULTC 제어기 설계에 대한 연구 (A Study on the On-Line Fuzzy ULTC Controller Design Based on Multiple Load Center Points)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.514-521
    • /
    • 2006
  • The existing ULTC operation control strategy based on the measured data deteriorates the voltage compensation capability making the efficient corresponding to the load variation difficult by following the fixed load center point voltage. Accordingly, this paper proposes a new on-line fuzzy ULTC controller based on the designed multiple load center points which can improve the voltage compensation capability of ULTC and minimize voltage deviation by moving in real-time the load center point according to the load variation to an adequate position among the multiple load center points designed using the clustering technique. The Max-Min distance technique is adopted as the clustering technique for the decision of multiple load points from measured MTr load current and PTr voltage, and the minimum distance classifier is adopted for the decision of fuzzy output membership function. To verify the effectiveness of the proposed strategy, Visual C++ MFC-based simulation environments is developed. Finally, the superiority the proposed strategy is proved by comparing the fuzzy ULTC operation control results based on multiple load center points with the existing ULTC operation control results based on fixed load center point using the data for three day.

저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선 (Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation)

  • 김경훈;윤철;조내수;장민호;권우현
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

전압형 인버터로 구동되는 유도기의 안정화 제어 (The Stablized Control Method for The Voltage Source Inverter Fed Induction Motor Driver)

  • 노성채;이현우;이오걸;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.567-570
    • /
    • 1989
  • A constant V/F control system of voltage contrlled PWM inverter has a unstable operation of the low- speed and the light-load. In this paper, the authors propose stability control with idealized operation of induction motor by the neglect of primary leakage inductance and resistance. Also ldealized operation system is adopted voltage error, feed back impedance circuit, and increasing resistance from dead time of switching is compensated by the soft ware with u-processors. The proposed simulation of the idealized control method is proved at the low-speed operation for three phase induction motor.

  • PDF

비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어 (Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter)

  • 이해춘;박태열;김기택
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

배전계통에서의 분산전원 도입운용 관리방법 : LDC 운전을 하지 않을 경우 (A Control Method of Distributed Generation System Which is Connected to Power Distribution System : Without LDC Operation)

  • 정원재;김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.231-233
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers. So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper computes permissible operation limit of DGS when the DGS is connected to power distribution system using fixed tap(without LDC operation). For this simulation, KEPCO distribution system is used.

  • PDF

넓은 범위 입력전압에 소프트 스위칭이 가능한 양방향 인터리브드 DC-DC 컨버터 (Bidirectional Soft Switching Three-Phase Interleaved DC-DC Converter for a Wide Input Voltage Range)

  • 최우진;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.313-320
    • /
    • 2015
  • This study deals with a bidirectional interleaved soft switching DC-DC converter for a wide range of input voltages. The proposed converter operates in complementary switching with the purpose of inductor size reduction and zero-voltage switching (ZVS) operation. The current ripple related to complementary switching is minimized by three-phase interleaved operation. The main characteristics of the proposed topology are its soft-switching method of operation and its simple structure. The soft-switching operation and the system efficiency of the proposed converter are verified by experimental results.

가중효율을 적용한 2-Stage Boost 컨버터 최적효율 운전 연구 (Optimal Efficiency Operation of 2-Stage Boost Converter With Weighted Efficiency)

  • 김승민;김동희
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.285-293
    • /
    • 2021
  • An optimal operation method based on weighted efficiency for a two-stage boost converter is proposed in this study. Detailed loss analysis of the converter is performed to derive the optimal operation method according to the load and input voltage fluctuations, and the optimal DC-bus voltage is derived by applying the weighted efficiency method. The proposed method can satisfy optimal efficiency in the main operation region without a complicated control method. Using 1kW typical two-stage boost converter and is verified three types of weighted efficiency formulas and loss analysis are utilized to derive high-efficiency optimal DC-bus voltage from each load range.

Single-Phase Z-Source AC/AC Converter with Wide Range Output Voltage Operation

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.736-747
    • /
    • 2009
  • A new type of single-phase Z-source AC/AC converter based on a single-phase matrix converter is proposed in this paper. The proposed single-phase Z-source AC/AC converter has unique features; namely that the output voltage can be bucked and in-phase/out-of-phase with the input voltage; that the output voltage can be boosted and in-phase/out-of-phase with the input voltage. The converter employs a safe-commutation strategy to conduct along a continuous current path, which results in the elimination of voltage spikes on switches without the need for a snubber circuit. The operating principles of the proposed single-phase Z-source AC/AC converter are described, and a circuit analysis is provided. To verify the performance of the proposed converter, a laboratory prototype based on a TMS320F2812 DSP was constructed. The simulation and the experimental results verified that the output voltage can be bucked-boosted and in-phase with the input voltage, and that the output voltage can be bucked-boosted and out-of-phase with the input voltage.

저전압 밴드갭 기준 전압 발생기 설계 (A Low Voltage Bandgap Reference Voltage Generator Design and Measurement)

  • 심외용;이재형;김종희;김태훈;박무훈;하판봉;김영희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.785-788
    • /
    • 2007
  • 새롭게 제안된 밴드갭 기준전압 발생기는 PVT변동에 둔감하면서 기존의 밴드갭 기준전압 발생기보다 안정적인 동작을 하기 위해 요구되는 최소 전원전압(VDD)의 크기을 낮추었다. 모의실험 결과 전원전압(VDD)이 1.0V의 낮은 전압에서 안정적인 동작을 하는 것을 확인 하였다. 매그나칩 반도체 $0.18{\mu}m$ DDI 공정을 이용하여 Layout 하였고, 사이즈는 $409.36{\mu}m$ ${\times}$ $435.46{\mu}m$ 이다.

  • PDF