• Title/Summary/Keyword: Operation technique

Search Result 3,214, Processing Time 0.038 seconds

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

시뮬레이션을 이용한 비행장능력 평가모형에 관한 연구 (A Study on Modelling the Airfield Capacity by using Simulation)

  • 오승학;이상진
    • 한국국방경영분석학회지
    • /
    • 제26권1호
    • /
    • pp.15-33
    • /
    • 2000
  • This paper deals with an estimation method of the airfield capacity for the airlift operation. In the US Air Force, airfield capacities has been estimated using MOG(Maximum -On-the-Ground) concept, which is known to having several weaknesses. Recently, RAND suggests a personal-computer- based model called the Airfield Capacity Estimator(ACE), which is a more advanced and realistic technique compared to the MOG. This paper attempts to modify the ACE appropriate to the Korean airlift operation. While ACE is developed on the basis of strategic mobilization, Korean airlift operation is done on the tactical basis. A designed mdel is tested with simulation technique.

  • PDF

A Case of Pedicle Screw Loosening Treated by Modified Transpedicular Screw Augmentation with Polymethylmethacrylate

  • Kang, Suk-Hyung;Kim, Kyoung-Tae;Park, Seung-Won;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권1호
    • /
    • pp.75-78
    • /
    • 2011
  • We report a case of pedicle screw loosening treated by modified transpedicular screw augmentation technique using polymethylmethacrylate(PMMA), which used the anchoring effect of hardened PMMA. A 56-year-old man who had an L3/4/5 fusion operation 3 years ago complained of continuous low back pain after this operation. The computerized tomography showed a radiolucent halo around the pedicle screw at L5. We augmented the L5 pedicle screw with modified pedicle screw augmentation technique using PMMA and performed an L3/4/5 pedicle screw fixation without hook or operation field extension. This modified technique is a kind of transpedicular stiffness augmentation using PMMA for the dead space around the loosed screw. After filling the dead space with 1-2 cc of PMMA, we inserted a small screw. Once the PMMA hardened, we removed the small screw and inserted a thicker screw along the existing screw threading to improve the pedicle screws' pullout strength. At 10 months' follow-up, x-ray showed strong fusion of L3/4/5. The visual analogue scale (VAS) of his back pain was improved from 9 to 5. This modified transpedicular screw augmentation with PMMA using anchoring effect is a Simple and effective surgical technique for pedicle screw loosening. However, clinical analyses of long-term follow-up and biomechanical studies are needed.

논 블록킹 검색연산을 위한 R-tree 기반의 동시성 제어 기법 (A Concurrency Control Method for Non-blocking Search Operation based on R-tree)

  • 김명근;배해영
    • 정보처리학회논문지D
    • /
    • 제11D권4호
    • /
    • pp.809-822
    • /
    • 2004
  • 본 논문에서는 검색 위주의 공간 데이터베이스 시스템을 위한 R-tree 기반의 동시성 제어 기법을 제안한다. 기존의 제안된 기법들은 검색연산이 갱신연산과 동시에 수행되는 것을 막기 위해 노드에 공유 락이나 래치를 획득함으로써 갱신연산으로 인한 검색연산의 블록킹을 막을 수 없다는 문제를 가지고 있으며, 또한 R-tree같은 다차원 색인의 경우 갱신연산의 락 획득은 여러 노드에 걸쳐 일어날 수 있으며, 노드 분할과 같은 경우 오랜 시간동안 락을 획득하고 있을 수도 있기 때문에 검색연산은 장시간 블록킹이 되어야 하는 문제를 갖는다. 따라서 본 논문에서는 이러한 문제를 해결하기 위하여 노드의 엔트리들을 링크드 리스트로 연결하는 방법을 사용하여 노드에 엔트리를 삽입하고 있는 중에도 락이나 래치를 획득하지 않고 검색연산을 할 수 있는 링크드 리스트 기반의 동시성 제어 기법과, 노드 분할이 진행 중에 있는 노드에도 검색연산이 락이나 래치를 획득하지 않고 노드를 탐색할 수 있는 버전 기반의 동시성 제어 기법을 제안한다.

Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료 (Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion)

  • 김재원;정성모
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

Self-Power Gating Technique For Low Power Asynchronous Circuit

  • Mai, Kim-Ngan Thi;Vo, Huan Minh
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.548-557
    • /
    • 2018
  • In this paper, Asynchronous Self-Power Gating technique (ASPG) is used to reduce consumption power in asynchronous digital watch application. The power gating control signal is automatically generated by internal system operation characteristics instead of using replica circuit delay or four-phase handshaking protocol. Isolation cell is designed to insert it between power gating domain and normal operation domain. By using self-power gating circuit, asynchronous digital watch application consumes very low power and maintains data during sleep mode. The comparison results show the proposed ASPG technique saves leakage power up to 40.47% and delay time is reduced to 71% compared to the conventional circuit.

발전소 설비 운영상태 지능감시 시스템 개발 (Development of an Intelligent Power Plant Operating State Monitoring System)

  • 홍창호;김석현;이승철
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.38-43
    • /
    • 2012
  • For safe and stable operations of power plants, it is essential to monitor closely crucial measurement values related to power plant trips. In this paper, an intelligent power plant operating state monitoring technique enabling the operating crew member to monitor conveniently the status of the important measurement values and to perceive almost instantly the significance of the implications of those measurement values is developed. The proposed technique is called a "POST(Plant Operating State Tracking) Chart" technique and provides the foundations in developing an intelligent and integrated power plant operating state monitoring support system called the "P-OASIS"(Plant Operation Assessment and Support Intelligent System). The P-OASIS is applied to a thermal power plant of 500[MW] capacity and exhibited impressive performances.

An Excessive Current Subtraction Technique to Improve Dynamic Range for Touch Screen Panel Applications

  • Heo, Sanghyun;Ma, Hyunggun;Bien, Franklin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.375-379
    • /
    • 2016
  • A current subtraction technique with parallel operation system is proposed to remove excessive current in touch screen application. The proposed current subtraction remove the current which go into the input node of charge amplifier. The value of subtraction current is same with current when touch screen is not touched. As a result, charge amplifier output is only proportional to variation of mutual capacitor, which make dynamic rage is increased. Also, Transmitter (Tx) driving signal and subtraction driving signal are out of phase each other. Thus, noise generated in Tx is cancelled. The proposed IC is implemented in a mixed-mode 0.18-um CMOS process. Overall system is designed for touch screen panel (TSP) with 16 driving lines and 8 sensing lines. 5-V supply voltages are used in the proposed circuits. For multiple Tx driving signal, Walsh codes are used and signal frequency is 300 khz. By using proposed technique, dynamic rage is improved 36 dB.

Simplification of Monte Carlo Techniques for the Estimation of Expected Benefits in Stochastic Analysis of Multiple Reservoir System

  • Lee, Kwang-Man;Ko, Seok-Ku
    • Korean Journal of Hydrosciences
    • /
    • 제5권
    • /
    • pp.57-70
    • /
    • 1994
  • For the system benefit optimization by considering risk or reliability from a multiple reservoir system using the Monte Carlo Technique, Many stochastically generated inflow series have to be used for the system analysis. In this study, the stochastically generated inflow series for the multiple reservoir system operation are preprocessed according to the considering system objectives and operating time periods. Through this procedure, several representative inflow series which have discrate probability levels and operation horizons are selected among the thousands of generated inflows. Then a deterministic optimization technique is applied to the hydropower energy estimation from the Han River Reservoir System which considers five reservoirs in this study. It took much less computational requirements than using the original Morite Carlo Technique, even though estimated result was almost similar.

  • PDF