• Title/Summary/Keyword: Operation Rate

Search Result 5,352, Processing Time 0.033 seconds

Adhesion Characteristics and the High Pressure Resistance of Biofilm Bacteria in Seawater Reverse Osmosis Desalination Process (역삼투 해수담수화 공정 내 바이오필름 형성 미생물의 부착 및 고압내성 특성)

  • Jung, Ji-Yeon;Lee, Jin-Wook;Kim, Sung-Youn;Kim, In-S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.51-57
    • /
    • 2009
  • Biofouling in seawater reverse osmosis (SWRO) desalination process causes many problems such as flux decline, biodegradation of membrane, increased cleaning time, and increased energy consumption and operational cost. Therefore biofouling is considered as the most critical problem in system operation. To control biofouling in early stage, detection of the most problematic bacteria causing biofouling is required. In this study, six model bacteria were chosen; Bacillus sp., Flavobacterium sp., Mycobacterium sp., Pseudomonas aeruginosa, Pseudomonas fluorescens, and Rhodobacter sp. based on report in the literature and phylogenetic analysis of seawater intake and fouled RO membrane. The adhesion to RO membrane, the high pressure resistance, and the hydrophobicity of the six model bacteria were examined to find out their fouling potential. Rhodobacter sp. and Mycobacterium sp. were found to attach very well to RO membrane surface compared to others used in this study. The test of hydrophobicity revealed that the bacteria which have high hydrophobicity or similar contact angle with RO membrane ($63^{\circ}$ of contact angle) easily attached to RO membrane surface. P. aeruginosa which is highly hydrophilic ($23.07^{\circ}$ of contact angle) showed the least adhesion characteristic among six model bacteria. After applying a pressure of 800 psi to the sample, Rhodobacter sp. was found to show the highest reduction rate; with 59-73% of the cells removed from the membrane under pressure. P. fluorescens on the other hand analyzed as the most pressure resistant bacteria among six model bacteria. The difference between reduction rates using direct counting and plate counting indicates that the viability of each model bacteria was affected significantly from the high pressure. Most cells subjected to high pressure were unable to form colonies even thought they maintained their structural integrity.

Analysis of Recurred Mitral Regurgitation after Mitral Repair according to Procedure or Valve Related Causes (승모판막 성형술 후 재발의 원인에 대해 술기와 판막 요인에 대한 분석)

  • Shin Hong Ju;Yoo Dong Gon;Lee Yong Jik;Park Soon Ik;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.132-138
    • /
    • 2005
  • Background: Mitral valve repair (MVP) is the optimal procedure for mitral regurgitation (MR), however, failure and subsequent reoperations are the limitations. The current study assessed the procedure in relation to the primary valve related causes of recurrent MR. Material and Method: MR was treated in 493 patients undergoing MVP from January of 1994 to January of 2002. The causes of MR were degenerative $(n=252,\;51.5\%),$ rheumatic $(n=156,\; 31.6\%),$ and others $(n=85,\; 16.9\%).$ Surgery comprised 446 ring annuloplasties $(90.5\%),$ 227 new chordae formations $(46\%),$ 125 quadriangular resections $(25.3\%),$ 28 chordae transfers $(5.7\%),$ and 8 Alfieri's stitches $(1.6\%).$ The mean follow up was $29.04\pm22.81$ months. Result: There were 5 early $(1.01\%)$, and 5 late deaths $(1.01\%).$ The reoperation rate was $1.42\%$. There were 45 $(9.1\%)$ recurrent MR (grade III or IV). Of these, 24 were procedure related including incomplete repair (n=14), discordant new chordae length (n=8) and others (n=2). In 21 patients, the cause was valve related including rheumatic disease progression (n=10), recurrent chordae elongation or prolapse (n=5) and others (n=6). Severe MR was higher after incomplete repair (p < 0.001), and valve related failure strongly correlated with rheumatic progression (p < 0.05). Conclusion: Since completeness of operation is the prime risk factor that determine the repair durability, intra-operative assessment of the initial repair with trans-esophageal echocardiography is essential.

Comparison of the Reconstruction Routes after Esophagectomy for Esophageal Cancer (식도암 절제후 식도 재건경로의 비교)

  • Lee, Seung-Yeoll;Kim, Kwang-Taik;Choi, Young-Ho;Kim, Il-Hyun;Baik, Man-Jong;Sun, Kyung;Lee, In-Sung;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.806-812
    • /
    • 1999
  • Background: Selection of reconstruction route in esophageal cancer surgery is based on the patient's status, characteristics of tumor, surgeon's preference and experience. Of the various routes, it has been documented that subcutaneous or substernal route may prolong operation time and may be vulnerable to postoperative respiratory complications. This study was designed to evaluate whether the selection of reconstruction route affects the surgical outcomes. Material and Method: Of 131 patients who have undergone resection and reconstruction for esophageal cancer, posterior mediastinal route(Group I, n=34), substernal route (Group II, n=31), and subcutaneous route(Group III, n=21) were retrospectively reviewed in 86 patients. Results of early operations and morbidities were compared between the groups. Result: There was a male prevalence(79 of males vs. 7 of females). There were 81 squamous cell cancers and 5 adenocarcinomas. There were no differences between groups in weight, height, age, cancer staging and location, and in the preoperative anesthetic risk evaluation and pulmonary function test(p=NS). Postoperative mechanical ventilation time was longer in Group I(20.6 hours) than in Group II(7.8 hours) or III(3.4 hours)(p=0.005). Duration of stay in the intensive care unit was prolonged in Group III(6.4 days) compared to Group I (3.9 days) or II(3.1 days)(p=0.043). No differences were noted in the duration of hospital stay between the groups(p=NS). Blood transfusion was needed in 30 out of 34 patients in Group I compared to 14/31 in Group II or 15/21 in Group III(p=0.001). The mean amount of transfusion for each patient was also higher in Group I(3,833 mL) than in Group II(1535 mL) or Group III(1419 mL)(p=0.04), but there was no difference in the inreoperation due to bleeding. Ea ly mortality rate was substantially higher in Group I(17.6%) but the differences between the groups were insignificant(p=NS). Although sepsis was a more prevalent cause of death in Group I, it was not related to anastomotic leak. Other morbidities did not differ between the groups(p=NS). Conclusion: In above results show that the reconstruction route does not affect the outcome of esophageal cancer surgery. We believe that the selection of reconstruction route can be based on the surgeon's preference and experience.

  • PDF

Aortopulmonary Window (대동맥폐동맥창)

  • Kim Dong-Jin;Min Sun-Kyung;Kim Woong-Han;Lee Jeong-Sang;Kim Yong-Jin;Lee Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.275-280
    • /
    • 2006
  • Background: Aortopulmonary window (APW) is a very rare congenital heart anomaly, often associated with other cardiac anomalies. It causes a significant systemic to pulmonary artery shunt, which requires early surgical correction. Accurate diagnosis and surgical correction will bring good outcomes. The purpose of this study was to describe our 20-year experience of aortopulmonary window. Material and Method: Between March 1985 and January 2005, 16 patients with APW underwent surgical repair. Mean age at operation was $157.8{\pm}245.3$ ($15.0{\sim}994.0$) days and mean weight was $4.8{\pm}2.5$ ($1.7{\sim}10.7$) kg. Patent ductus arteriosus (8), atrial septal defect (7), interruptedaortic arch (5), ventricular septal defect (4), patent foramen ovate (3), tricuspid valve regurgitation (3), mitral valve regurgitation (2), aortic valve regurgitation (1), coarctation of aorta (1), left superior vena cavae (1), and dextrocardia (1) were associated. Repair methods included 1) division of the APW with primary closure or patch closure of aorta and pulmonary artery primary closure or patch closure (11) and 2) intra-arterial patch closure (3). 3) Division of the window and descending aorta to APW anastomosis (2) in the patients with interrupted aortic arch or coarctation. Result: There was one death. The patient had 2.5 cm long severe tracheal stenosis from carina with tracheal bronchus supplying right upper lobe. The patient died at 5th post operative day due to massive tracheal bleeding. Patients with complex aortopulmonary window had longer intensive care unit and hospital stay and showed more morbidities and higher reoperation rates. 5 patients had reoperations due to left pulmonary artery stenosis (4), right pulmonary artery stenosis (2), and main pulmonary artery stenosis (1). The mean follow-up period was $6.8{\pm}5.6$ (57.0 days$\sim$16.7 years)years and all patients belonged to NYHA class 1. Conclusion: With early and prompt correction of APW, excellent surgical outcome can be expected. However, optimal surgical method needs to be established to decrease the rate of stenosis of pulmonary arteries.

Acute Renal Failure after On-pump Coronary Artery Bypass Surgery (체외순환하 시행한 관상동맥우회술 후 발생한 급성신부전증)

  • Jin, Ung;Jo, Min-Seop;Park, Chan-Beom;Sa, Young-Jo;Kim, Chi-Kyung
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.416-422
    • /
    • 2004
  • Acute renal failure (ARF) is a common postoperative complication after the cardiac surgery. Postoperative ARF have various causes, and are combined with other complications rather than being the only a complication. It deteriorates the general condition of the patient, and makes it difficult to manage the combined complications by disturbing the adequate medication and fluid therapy. We have planned this study to evaluate the effects of postoperative ARF after the on-pump coronary artery bypass surgery (CABG) on the recovery of patients and identify the risk factors. Method and Material: We reviewed the medical records of patients who underwent CABG with cardiopulmonary bypass by a single surgeon from Jan. 2000 to Dec. 2002, We checked the preoperative factors; sex, age, history of previous serum creationism over 2.0 mg/㎗, preoperatively last checked serum creatinine, diabetes, hypertension, left ventricular ejection fraction, intraoperative factors; whether the operation is an emergent case or not, cardiopulmonary bypass time, aortic cross clamp time, the number of distal anastomosis, postoperative factors: IABP. Then we have studied the relations of these factors and the cases of postoperative peak serum creatinine over 2.0 mg/㎗. Result: There were 19 cases with postoperative peak serum creatinine over 2.0 mg/㎗ in a total 97 cases. Dialysis were done in 3 cases for ARF with pulmonary edema and severely reduced urine output. There were 8 cases (42.1%) with combined complications among the 19 patients. This finding showed a significant difference from the 5 cases (6,4%) in the patients whose creatinine level have not increased over 2.0 mg/㎗. The mortalities are different as 1.3% to 10.5%. The risk factors that are related with postoperative serum creatinine increment over 2.0 mg/㎗ are diabetes, the history of previous serum creatinine over 2.0 mg/㎗ and left ventricular ejection fraction. Conclusion: Postoperative ARF after the on-pump CABG is related with preoperative diabetes, the history of previous serum creatinine over 2,0 mg/㎗ and left ventricular ejection fraction. Postoperative ARF could De the reason for increased rate of complications and mortality after on-pump CABG. Therefore, in the patients with these risk factors, the efforts to prevent postoperative ARF like off-pump CABG should be considered.

The Mid Term Clinical Result and the Risk Factor Analysis of Isolated Aortic Valve Replacement (단독 대동맥판막 치환술의 중기 성적과 그 위험인자에 대한 분석)

  • Park Jae-Min;Jun Hee-Jae;Yoon Young-Chul;Lee Yang-Hang;Hwang Yoon-Ho;Cho Kwang Hyun;Han Il-Yong
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.110-115
    • /
    • 2005
  • Background: The aims of this paper were to review the mid term clinical results and to analyze the preoperative risk factors of isolated aortic valve replacement (AVR). Material and Method: Between January 1992 and February 2003, 80 patients underwent isolated AVR. 58 were male and 22 were female patients, raging from 12 to 75 years of age (mean :$46.8{\pm}13.0$ years). 74 patients except one early death and 5 follow-up loss were contacted by OPD or by telephone. The mean duration of follow-up was $44.2{\pm}29.7$ months and the total cumulative period was 272.8 patient-year. Result: The complications in hospital occurred in 35 cases : 12 wound problems (11 superficial, 1 deep), 11 arrhythmias (9 temporary, 2 persistent), 3 low cardiac output, and so forth. The late deaths were 4 cases : the heart-related deaths were 2 cases ($0.7\%$ patient-year). Conclusion: The risk factors that influenced the early mortality and morbidity were older age (> 60 years)(p=0.04), poor preoperative NYHA functional class (> 3) (p=0.048), high preoperative serum creatinin level (> 1.2 mg/100 ml)(p=0.031), long operation time (aortic clamping time>90 min)(p=0.042). The same factors influenced the late mortality and morbidity. Freedom from valve-related complication was $86.4{\pm}5.3\%,$ actuarial survival rate were $96.8{\pm}2.3\%$ at 3 years and $90.8{\pm}4.6\%$ at 10 years.

Clinical Experiences of Congenital Aortic Stenosis (선천성 대동맥 판막협착증의 임상 경험)

  • Jeong, Dong-Seop;Ra, Yong-Joon;Lee, Jeong-Ryul;Kim, Yong-Jin;Lee, Chang-Ha;Lee, Cheul;Lim, Hong-Gook;Hwang, Seong-Wook;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.17-24
    • /
    • 2007
  • Background: The aim of this study is to assess the clinical results of various procedures in congenital aortic stenosis. Material and Method: From August 1987 to June 2004, 53 patients of congenital aortic stenosis underwent procedures such as percutaneous balloon valvuloplasty, aortic valvuloplasty, Ross procedure, and aortic valve replacement. The mean age of initial procedures was $8.2{\pm}6.0$ years. Percutaneous balloon valvuloplasty was peformed in sixteen patients, aortic valvulopiasty in thirty two patients, Ross procedure in nineteen patients, and aortic valve replacement in fourteen patients. The mean follow duration was $80.6{\pm}60\;(0{\sim}207)$ months. Result: There was 15.1% (8/53) of early mortality and no late mortality. The six patients with critical aortic stenosis were died of left ventricular dysfunction in early series (before 1 year; 4 cases) and two patients died after the Ross procedure and aortic valve replacement respectively. After percutaneous balloon valvuloplasty, most patients needed reoperations (14/16). Thirteen patients needed reoperation, after aortic valvuloplasty. After Ross procedure, two patients needed reoperation due to aortic regurgitation caused by progressive aortic root dilatation. The actuarial survival rate after Ross procedure at 7 years was 90.5%. Conclusion: In young children before the age of one, percutaneous balloon valvuloplasty was considered as :he safe initial palliative procedure. But children over one year-old, aortic valvuloplasty were the effective procedure. Ross procedure can be preformed safely with good results.

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

Clinical Effects of an Improved Pump Reaction Rate and Automatic Occlusion Sensing System in Phacoemulsification (수정체유화장치의 초음파 출력속도 및 자동막힘감지 기능 향상의 술 후 임상결과 비교)

  • Kim, You Na;Lee, Jin Ah;Kim, Jae Yong;Kim, Myoung Joon;Tchah, Hung Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1017-1023
    • /
    • 2018
  • Purpose: A recently introduced phacoemulsification system, the WhiteStar $Signature^{(R)}$ PRO, has demonstrated improved nucleus followability and cutting efficiency via an improved pump regulator with a higher reaction response and an automatic occlusion sensing system. In this study, we compared various phacoemulsification parameters between the new system and an older version of the device. Methods: A total of 80 eyes of 68 patients with cataracts who had undergone phacoemulsification by a single surgeon were included in this study. Forty eyes of patients underwent phacoemulsification using the older $Signature^{(R)}$ system (WhiteStar); these patients were classified as the control group. Another 40 eyes of patients underwent phacoemulsification with the newer enhanced system, the WhiteStar $Signature^{(R)}$ PRO; these patients were assigned to the experimental group. During the operation, operative parameters, including the effective phaco time (parameter of effective phaco time with a specific coefficient for the transversal movement expressed in seconds, EFX), ultrasound time (seconds [s]), effective phacoemulsification time (EPT, s), average phacoemulsification power (AVG, %), and balanced salt solution usage, were measured to determine the performance enhancement offered by the updated system. Central corneal thickness was measured before and after surgery to compare corneal edema. The relationships between the two groups were analyzed using an independent t-test. Results: The Signature $PRO^{(R)}$ system showed a lower EFX (p < 0.001), a shorter EPT (p < 0.001), and a smaller AVG (p < 0.001). Postoperative corneal thickness did not differ significantly between the two groups. Conclusions: Comparing the efficacy of the improved reaction speed of the device and automatic occlusion sensing system in performing phacoemulsification, the updated Signature $PRO^{(R)}$ system demonstrated superior followability and cutting efficiency regardless of nuclear cataract hardness.

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.