• Title/Summary/Keyword: Operation Deviation

Search Result 425, Processing Time 0.026 seconds

Correlation between Operation Result and Patient Satisfaction of Nasal Bone Fracture

  • Kang, Chang Min;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.1
    • /
    • pp.25-29
    • /
    • 2017
  • Background: Many authors have evaluated the post-reduction result of nasal bone fracture through patient satisfaction or postoperative complications. However, these results are limited because they are subjective. The aim of this study was to correlate an objective operation result with patient satisfaction and postoperative complications according to the type of nasal bone fractures. Methods: Our study included 313 patients who had isolated nasal bone fractures and had undergone a closed reduction. Postoperative outcomes were evaluated objectively using computed tomographic (CT) images, while patient satisfaction was evaluated one month after the operation. The correlation of the operation result with patient satisfaction was then evaluated. Results: The correlation between the operation result and patient satisfaction was highest for the lateral impact group type I (LI) type of fracture and lowest for the comminuted fracture group (C) type of fracture. However, there were no statistically significant differences in correlation between the overall result and patient satisfaction by fracture type. The complication rate of lateral impact group type II (LII), C, and frontal impact group type I (FI) fractures were statistically significantly higher than that of frontal impact group type II (FII) and LI fractures. There were no statistically significant relationships between the prevalence of complications and septal fracture or deviation according to the fracture type. In the total group, however, there was a statistically significant difference in complication rate by septal fracture. Conclusion: We found that the CT outcomes correlated with patient satisfaction. The complication rate of LII, C, and FI fractures were statistically significantly higher than that of FII and LI fractures. Septal fracture/deviation increased the postoperative complication in the total group.

The Radiological Study on the Pelvic Deviation in Delivery Women (출산유형이 산모의 골반변위에 미치는 영향에 관한 방사선학적 연구)

  • Kim, Cheol-Han;Kim, Hui-Jun;Shin, Byung-Cheul;Kim, Jeong-Yeon
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • Objective : Women can be affected physically and psychologically by pregnancy and delivery. Because the relaxation of pelvic ligaments has a chance to cause pelvic deviation, we investigated the radiological peivic deviation according to delivery types and experiences. Method : 71 patients were evaluated by X-ray findings. Every patients divided into two group according to delivery types and experiences. After measured innominate measurement. off centering measurement, sacral ala measurement and ilium shadow measurement, X-ray findings in each group were analyzed statistically. Results and Conclusions : It was concluded that the ilium was more deviated into outer side in normal delivery group than caesarean operation group, and more deviated into inner or outer side in multipara group than primipara group.

  • PDF

Driving technologies for AMOLEDs

  • Matsueda, Yojiro;Kim, Hong-Kwon;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.393-398
    • /
    • 2006
  • This paper classifies driving technologies for AMOLEDs by the driving TFT conditions in pixels. A saturation region operation type driving TFT circuit provides good stability of OLED because of constant current drive. However, complicated compensation circuits are necessary to avoid effect of the TFT characteristics deviation. On the other hand, a linear region operation type driving TFT circuit provides better uniformity of the display image and lower power consumption. However, the stability of OLED is critical because of constant voltage drive.

  • PDF

Appropriate Choice of Window Function for Noise Reduction (잡음 감소를 위한 창 함수의 선택에 관한 연구)

  • 백문열
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.3-8
    • /
    • 1997
  • This paper shows a performance estimation of windowing a single tone with added Gaussian noise and uniform noise. Signal-to-noise ratio can be determined by the ratio of the output noisy signal variance to the input noisy signal variance of a window. Standard deviation of noise is reduced by windowing Signal-to-noise ratio of the noisy signal is reduced by the windowing operation. Thus, performance of window function can be determined by this filtering operation that improved the signal-to-noise ratio.

  • PDF

Investigation of Cyclic Variations of IMEP Under Idling Operation in Spark Ignition Engines

  • Han, Sung-Bin
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.81-87
    • /
    • 2001
  • Cyclic variability limits the range of operating conditions of spark ignition engines, especially under lean and highly diluted operation conditions. The cyclic combustion variations can be characterized by pressure parameters, combustion related parameters, and flame-front related parameters. The coefficient of variation (COV) in indicated mean effective pressure (IMEP) defines the cyclic variability in indicated work per cycle.

  • PDF

Characteristics of 5 kW Class Proton-Exchange-Membrane Fuel Cell(PEMFC) Stack according to the Long-Term Operation (장기운전에 따른 5 kW급 고분자 전해질 연료전지 스택의 특성)

  • Kim, Jae-Dong;Lee, Jung-Woon;Park, Dal-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.40-43
    • /
    • 2007
  • The performance of PEMFC stack can be improved significantly by optimizing the design and operating conditions. As a result, the performance of daily operation showed slight deviation (0.02-0.9%) after accumulated DSS operation for 500 hrs but the stack performance was stable. Therefore, it is confirmed that it would be improved the life-time of stack and operation reliability for the commercialization of PEMFC system.

  • PDF

The Deviation Distribution of Target on the ILS Final Approach Segment Using ADS-B Message (ADS-B 신호를 이용한 ILS 최종접근 구간의 항공기 항적 이격 분포 도출)

  • Ku, SungKwan;Lee, Young-Jong;Shin, DaiWon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.403-410
    • /
    • 2015
  • ADS-B can provide high accurate position information and faster update rate than Radar system and it is a technique that can supplement or replace the Radar. Recently ADS-B has been applied to the actual aircraft operation because to increase air transportation traffic and required to high accurate surveillance. In this study, we surveyed analysis of position deviation distribution analysis and received actual ADS-B trajectory data for conformed precise surveillance on the near airport area using ADS-B message. For that, we received the precision instrument approach ADS-B trajectory data using instrument landing system, and can analyse about target deviation distribution on the final approach segment about precision instrument approach. The result of analysis is mean distance of target deviation -0.04 m and standard deviation 6.71 m on between ADS-B target and extended runway centerline. Also that is to conformed the ADS-B message trajectory available to provide relatively exact surveillance information.

The change of air lead concentrations in litharge making and smelting industries (일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화)

  • Choi, Jae-Wook;Kim, Nam-Soo;Cho, Kwang-Sung;Ham, Jung-O;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

Analysis of Installation Effect of Section Speed Enforcement System Using ITS Collection and Operation Data (ITS 수집 및 운영 자료를 활용한 구간과속단속시스템 설치효과 분석)

  • Yoon, Young-Min
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.12
    • /
    • pp.302-309
    • /
    • 2021
  • The section speed enforcement system measures the starting instantaneous speed, the The section speed enforcement system measures the starting instantaneous speed, the ending instantaneous speed, and the section average speed, and imposes fines only for the portion that has been speeding the most. However, according to the Road Traffic Act, most of the systems are installed on highways, so existing research has been conducted on highway sections. In this study, it is expected that the installation of section speed enforcement systems on general national roads will be expanded according to the revision of related laws. ITS collection and operation data targeting the section speed enforcement system installed on National Road 3 Seongnam Icheon-ro was used to analyze traffic speed, standard deviation of traffic speed, and reduction in traffic accidents by dividing it into before installation, trial operation period, and after crackdown. As a result of the analysis, the traffic speed, standard deviation, and traffic accidents decreased by 13%, 25%, and 70%, respectively, after installation, confirming that the installation of the section speed enforcement system greatly contributed to the reduction of accidents.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.