• 제목/요약/키워드: Operation Conditions

검색결과 4,636건 처리시간 0.031초

임펄스전압에 대한 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages)

  • 이복희;장석훈;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

영국 화물철도운영자(EWS)와 코레일(한국철도공사) 교번근무제도 비교연구 (Comparison study for train crews and pilots operation system between EWS of UK and KORAIL of Korea)

  • 채일권;황선경;박찬홍;전영석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1871-1877
    • /
    • 2009
  • KORAIL has been established by 1st January 2005. From organization change to KORAIL(Korea railroad Corporation), labour union and company management team has been argument for their train crews and drivers operation system. For example, train crew and driver working conditions; working hours per week, off day and duty day time, over night time working payment, current position payment, preparation time, company own lodge operation and so on. I assure that this comparison study for train crew and driver operation between KORAIL and EWS will helps to improve other korean railway companies management efficiency. In conclusion, EWS has 4$\sim$6 times more efficient employee for active operation than KORAIL per 1 freight brock-train operation. EWS has very resonable train crews and driver operation system, and self-control regulation for employee and management team with trusty. This thesis propose that korean railway companies and their own labour unions need joint research and benchmarking other oversea railway companies as like EWS.

  • PDF

국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가 (Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul)

  • 이윤선;이겨레;정웅준;임재한
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.

Strategy to coordinate actions through a plant parameter prediction model during startup operation of a nuclear power plant

  • Jae Min Kim;Junyong Bae;Seung Jun Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.839-849
    • /
    • 2023
  • The development of automation technology to reduce human error by minimizing human intervention is accelerating with artificial intelligence and big data processing technology, even in the nuclear field. Among nuclear power plant operation modes, the startup and shutdown operations are still performed manually and thus have the potential for human error. As part of the development of an autonomous operation system for startup operation, this paper proposes an action coordinating strategy to obtain the optimal actions. The lower level of the system consists of operating blocks that are created by analyzing the operation tasks to achieve local goals through soft actor-critic algorithms. However, when multiple agents try to perform conflicting actions, a method is needed to coordinate them, and for this, an action coordination strategy was developed in this work as the upper level of the system. Three quantification methods were compared and evaluated based on the future plant state predicted by plant parameter prediction models using long short-term memory networks. Results confirmed that the optimal action to satisfy the limiting conditions for operation can be selected by coordinating the action sets. It is expected that this methodology can be generalized through future research.

구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석 (Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire)

  • 유우준
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 연구에서는 구획 공간 화재 시 발열량이 급격히 변하는 조건에서 스프링클러헤드의 손실인자 변화에 따른 작동시간을 분석하였다. 이를 위해서 내화보드로 구성된 구획 공간의 크기가 폭 0.3 m, 세로 0.5 m, 길이 3.0 m인 구조물을 제작하고 헵탄(n-Heptane) 풀 화재 실험을 수행하여 구획 공간 내부의 온도 분포, 헵탄의 질량감소율 그리고 발열량을 산출하였다. 또한, Fire Dynamics Simulator (FDS) Version 6.5를 사용하여 실험 조건과 동일한 발열량을 가정하고 스프링클러헤드의 설치위치 및 손실인자(C-factor) 변화에 따른 작동 시간을 분석하였다. 그 결과 반응시간지수(Response Time Index, RTI)가 $100(m{\cdot}s)^{0.5}$이고 작동온도가 $72^{\circ}C$인 스프링클러는 화원 상층부의 기류 온도가 $100^{\circ}C$에서 $300^{\circ}C$로 상승하고, 기류의 속도가 약 0.7 m/s인 경우 C-factor = 0과 1일 때 스프링클러의 작동시간은 최소 30 s~60 s, C-factor = 3일 때 62 s에서 최대 92 s, C-factor = 5일 때 120 s 이상으로 나타났다.

Performance evaluation of TEDA impregnated activated carbon under long term operation simulated NPP operating condition

  • Lee, Hyun Chul;Lee, Doo Yong;Kim, Hak Soo;Kim, Cho Rong
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2652-2659
    • /
    • 2020
  • The methyl iodide (CH3I) removal performance of tri-ethylene-di-amine impregnated activated carbon (TEDA-AC) used in the air cleaning unit of nuclear power plants (NPPs) should be maintained at least 99% between 24 month-performance test period. In order for evaluating the effectiveness of TEDA-AC on the removal performance of CH3I in nuclear power plant during the operation of NPPs, the long-term test for up to 15 months was carried out under the simulated operating conditions (e.g., 25 ℃, RH 50%, ppb level poisoning gases injection) at nuclear power plants (NPPs). The TEDA-AC samples were analyzed with the Brunauer-Emmett-Teller (BET) specific surface area and TEDA content as well as CH3I penetration test. It is clearly evident that more than 99% of CH3I removal performance of TEDA-AC was observed in the TEDA-AC samples during 15 months of long-term operation under the simulated NPP operating conditions including the ppb level of organic and oxide form of poisoning gases. BET specific surface area and TEDA content that can affect the CH3I removal performance of TEDA-AC were also maintained as those in new TEDA-AC during 15 months of long-term operation.

시스템의 신뢰성(信賴性) 보증방법(保證方法)에 대(對)한 연구(硏究) (A Study on the Methods of Systems Reliability Assurance)

  • 이상용
    • 품질경영학회지
    • /
    • 제10권2호
    • /
    • pp.2-9
    • /
    • 1982
  • In principle the methods of increasing the reliability of complex system can be classified into the following four basic methods: (1) using the stand-by redundancy; (2) decreasing the failure rate of the system; (3) decreasing the time of continuous operation; (4) decreasing the mean repair time. Among the above four methods, it is generally known that the method of stand-by redundancy is the most effective general, to increase the reliability of systems. Therefor this paper aims to compare the gain in reliability which is achieved by applying stand-by redundancy with other methods, and to show the characteristics of each method From the comparison of the methods of increasing reliability, the following important facts are found: When the method of stand-by redundancy is used to increase the reliability of complex systems intended for long-term operation, a hight multiplicity of stand-by redundancy is required. Thus an increase of the reliability of complex system by applying stand-by redandancy is realized at the expense of characteristics such as weight, size, cost, increased complexity of operation conditions. And this property restricts its use in systems which are critical with respect to weight, size, cost or operation conditions. The method of stand-by redundancy is the most effective when this method is used to increase the reliability of complex systems intended for short-term operation, and the method of decreasing failure rate is the most effective when it is used to increase the reliability of systems intended for long-term use. The methods of increasing reliability discussed in this paper make it possible to make highly reliable systems. But it is not possible to make a highly reliable system using a single method of increasing reliability, even if it is the most effective one. Therefore it is recommended to use all or a majority of the above four methods by choosing it in accordance with the properties of the system under construction.

  • PDF

하수처리시설에서 총유기탄소(TOC) 처리를 위한 운영·관리 고찰 (A study on operation and management for TOC removal of public sewage treatment works)

  • 정동환;정현미;조양석;김은석;김창수;박준원;이원석
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.535-550
    • /
    • 2018
  • Total organic carbon (TOC) will replace chemical oxygen demand ($COD_{Mn}$) as an effluent water quality standard in public sewage treatment works (PSTWs) from 2021 in Korea. To ensure effective control of TOC in the effluent, investigation was carried out into TOC levels and sewage treatment operation factors in five target PSTWs using anaerobic-anoxic-aerobic ($A_2O$) processes, media, membrane, and sequencing batch reactor (SBR) technologies. TOC removal efficiencies appeared to be 93-96% on average. As a fraction of TOC, biodegradable dissolved organic carbon (BDOC) was reduced from 64% in the influent to 9% in the effluent in these PSTWs. During the investigation, biological treatment processes were applied flexibly for operation factors such as HRT, SRT, MLSS, F/M ratios and BOD volume loads, based on the influent characteristics and design conditions. As a result, we suggest efficient operating conditions in PSTWs by evaluating relationships between TOC removal and operation factors.

Wide Voltage Input Receiver with Hysteresis Characteristic to Reduce Input Signal Noise Effect

  • Biswas, Arnab Kumar
    • ETRI Journal
    • /
    • 제35권5호
    • /
    • pp.797-807
    • /
    • 2013
  • In this paper, an input receiver with a hysteresis characteristic that can work at voltage levels between 0.9 V and 5 V is proposed. The input receiver can be used as a wide voltage range Schmitt trigger also. At the same time, reliable circuit operation is ensured. According to the research findings, this is the first time a wide voltage range Schmitt trigger is being reported. The proposed circuit is compared with previously reported input receivers, and it is shown that the circuit has better noise immunity. The proposed input receiver ends the need for a separate Schmitt trigger and input buffer. The frequency of operation is also higher than that of the previously reported receiver. The circuit is simulated using HSPICE at 0.35-${\mu}m$ standard thin oxide technology. Monte Carlo analysis is conducted at different process conditions, showing that the proposed circuit works well for different process conditions at different voltage levels of operation. A noise impulse of ($V_{CC}/2$) magnitude is added to the input voltage to show that the receiver receives the correct logic level even in the presence of noise. Here, $V_{CC}$ is the fixed voltage supply of 3.3 V.

Optimization of Extraction Conditions for the Antibacterial Activity by Clove against Streptococcus mutans Using Evolutionary Operation-Factorial Design Technique

  • Choi, Ung-Kyu;Kim, Mi-Hyang;Kwon, Dae-Jun;Kwon, O-Jun;Lee, Nan-Hee
    • Food Science and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.899-903
    • /
    • 2008
  • This study was conducted in order to elucidate the optimum conditions for the extraction of clove that can be used to elicit antibacterial activity against Streptococcus mutans using the evolutionary operation (EVOP)-factorial design technique. Higher antibacterial activity was achieved in a higher extraction temperature of $80^{\circ}C$ ($r=0.7983^{**}$) and in a longer extraction time of 26 hr ($r=0.6867^*$). Antibacterial activity was not effected by differentiation of ethanol concentration in the extraction solvent (r=-0.0683). The maximum antibacterial activity of clove against S. mutans as determined by the EVOP-factorial design technique was obtained at an extraction temperature of $80^{\circ}C$, an extraction time of 26 hr and a 50% ethanol concentration. Furthermore, the population of S. mutans decreased from an initial concentration of 6.850 to 4.195 log CFU/mL in the third set that is more than 2.6 log cycles by EVOP-factorial design technique.