• Title/Summary/Keyword: Operation Characteristics

Search Result 7,644, Processing Time 0.034 seconds

Hysteresis Characteristics of a SFCL using a Magnetic Coupling of Coils with an Iron Core of Two Magnetic Paths (두 개의 자기경로 철심을 갖는 코일의 자기결합을 이용한 초전도 전류제한기의 히스테리시스 특성)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1073-1077
    • /
    • 2009
  • The iron core, which comprises the superconducting fault current limiter (SFCL) using magnetic coupling of coils, can be operated in the saturation region, especially at the initial fault period. This operation of the iron core in the saturation region deteriorates the fault current limiting operation of the SFCL. To solve the saturation problem of the SFCL using magnetic coupling of coils, the iron core with two magnetic paths, which has an air-gap in one of them, was adopted. In this paper, the hysteresis characteristics of SFCL using magnetic coupling of coils, which were wound in the iron core with two magnetic paths, were analyzed. Through comparative analysis on the hysteresis characteristics of the iron core comprising SFCL, the hysteresis characteristics of the iron core with two magnetic paths were confirmed to be kept in the non-saturation region during the fault period and thus, the effective fault current limiting operation of the SFCL using the magnetic coupling of coils could be performed.

Soft-Switched Synchronous Buck Converter for Battery Chargers

  • Dong, Zhiyong;Joung, Gyubum
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.138-146
    • /
    • 2019
  • In this paper, we proposed a soft-switched synchronous buck converter, which can perform charging the battery. The proposed converter has low switching loss even at high frequency operation due to its soft switching characteristics. The converter operates in synchronous mode to minimize conduction loss, resulting in small conduction loss, also. In this reason, the efficiency of the converter can be greatly improved even in high frequency. The size and weight of the converter can be reduced by high frequency operation of the converter. In this paper, we designed a battery charger with a switching frequency of 100 kHz. The designed converter also simulated to prove the converter's characteristics of synchronous operation as well as soft switching operation. The simulation shows that the proposed converter always meets the soft switching conditions of turning on and off switching in the zero voltage and zero current states. Therefore, simulation results have confirmed that the proposed battery charger had soft switching characteristics. The simulation results for transient response to charge current for the designed converter show that the converter responds to charge current commands quickly within 0.05 ms.

Operating Characteristics of Arc-induction Type DC Circuit Breaker (아크유도형 DC 차단기의 동작 특성)

  • Park, Sang-Yong;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.981-986
    • /
    • 2018
  • AC(alternating current) CB(circuit breaker) at the fault occurred in the existing AC distribution system is limiting the fault current through zero cross-point. However, DC(direct current) CB does not have zero cross-point. Therefore, arc occurred by on-off operation of DC CB is very huge. Nowadays, many research team are studying the way to decrease breaking time, which is one of the essential conditions in DC CB. We suggested novel arc-induction type DC CB in this paper. The proposed arc-induction type DC CB is composed of the mechanical Arc ring and DC CB. We confirmed the operation of arc-induction type DC CB through the HFSS(High Frequency Structure Simulator) 3D simulation program and performed the experiment for operation characteristics. Results showed that arcing time of the arc-induction type DC CB by using induction ring was faster than existing mechanical DC CB. On the transient system, we confirmed stable operation characteristics of the arc-induction type DC CB through the simulation and experimental results. We expect that the proposed arc-induction type DC CB technology is will go to stay ahead of the existing DC CB technology.

Changes in Sea Water Characteristics Due to Operation of Shihwa Tidal Power Plant (조력발전소 가동에 따른 시화 해역의 해수특성 변화)

  • Kang, Young Seung;Chae, Yeongki;Lee, Hyung Rae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.4
    • /
    • pp.219-235
    • /
    • 2013
  • In order to investigate the changes in sea water characteristics and stratification due to operation of Shihwa tidal power plant, three dimensional numerical model is used. In summer, the density of inner part of Shihwa Lake is more affected by salinity than water temperature due to fresh water discharge. Before tidal power plant operation, the sea water characteristics in Shihwa Lake shows relatively high temperature and low salinity. After tidal power plant operation, water temperature decreases slightly and salinity tends to increase in Shihwa Lake. Also, density increases and stratification tends to weaken by mixing with sea water.

A Study on the 0.5$\mu\textrm{m}$ Dual Gate High Voltage Process for Multi Operation Applications (Multi Operation을 위한 0.5$\mu\textrm{m}$Dual Gate 고전압 공정에 관한 연구)

  • 송한정;김진수;곽계달
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.463-466
    • /
    • 2000
  • According to the development of the semiconductor micro device technology, IC chip trends the high integrated, low power tendency. Nowadays, it can be showed the tendency of single chip in system level. But in the system level, IC operates by multi power supply voltages. So, semiconductor process is necessary for these multi power operation. Therefore, in this paper, dual gate high voltage device that operate by multi power supply of 5V and 20V fabricated in the 0.5${\mu}{\textrm}{m}$ CMOS process technology and its electrical characteristics were analyzed. The result showed that the characteristics of the 5V device almost met with the SPICE simulation, the SPICE parameters are the same as the single 5V device process. And the characteristics of 20V device showed that gate length 3um device was available without degradation. Its current was 520uA/um, 350uA/um for NMOS, PMOS and the breakdown voltages were 25V, 28V.

  • PDF

Characteristics on the Transformer-Type SFCL According to Reclosing Operation the Voltage Increase (전압증가 시 재폐로 동작에 따른 변압기형 초전도 한류기의 특성 분석)

  • Choi, Soo-Geun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.477-480
    • /
    • 2010
  • Fault current in power system is expected to increase by demand of power capacity. Therefore, when the fault occurred, fault current was increased in the power system. Many studies have been progressed to limit the fault current. Superconducting fault current limiter (SFCL) is one of them which has been studied in worldwide. In this paper, we will analyze characteristics of a transformer-type SFCL by reclosing operation when the voltage increases. Twice opening times in the reclosing of circuit breaker were set as the 0.5 and 15 seconds, respectively. Turn's number of primary and secondary coils set 4:2 and we increased voltages from 120V to 280V for each experiment. By the current waveform, maximum fault current in second and third cycles was lowered when the voltage was increased. In the recovery waveform, recovery time was increased as the voltage was increased. The reason was that power burden of the SFCL increased when consumption power was increased, so the time to get back to SFCL took longer. We compared the characteristics of a resistive-type and transformer-type SFCL. As a result, we found that the fault current of a transformer-type was lower than resistive-type and recovery time of the SFCL was shorter. Consequently, transformer-type SFCL was more profitable for limitation of fault current and recovery time under the same condition for reclosing operation.

A study on the optimum operation scheme with operating reserve power (운전예비력의 최적운용방식에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.28 no.5
    • /
    • pp.49-55
    • /
    • 1979
  • During severe emergencies which result in insufficient generation to meet load, an automatic load shedding method considering the spinning and operating reserve can establish the optimum system operation. This paper presents methods and results of a study on the optimum operating scheme with spinning and operating reserve power in case of outage of large generator units to prevent frequency decay and continue stable operation. This study covers following three parts 1) Analysis of spinning reserve characteristics 2) Determination of operating reserve requirements 3) Development of the optimum load shedding programs By this study the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Numerical Study on Dynamic Characteristics of Pintle Nozzle for Variant Thrust: Part 2 (가변 추력용 핀틀 노즐의 동적 특성에 관한 수치적 연구: Part 2)

  • Heo, Jun-Young;Kim, Ki-Wan;Sung, Hong-Gye;Yang, June-Seo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.123-128
    • /
    • 2012
  • According to the sequence of pintle operation, the performance characteristics of pintle nozzles are analyzed. The pintle movement was simulated using unsteady numerical techniques, the response lag and sensitivity at the chamber and nozzle are estimated for movable pintle. Three operation sequences of the pintle are considered for evaluating whether the rate of the chamber pressure increase and the operation sequence will have any significant impact towards the rocket performance. Three operation sequencies are as following; the pintle moves toward the nozzle throat, it turns instantly (case 1), stops at the nozzle throat for some time(0.5sec) (case 2), and stops at the nozzle throat (case 3). As a result, the dynamic characteristics according to the operation sequence and pintle shape were analyzed to take account the rocket performance.

  • PDF

A Study on Construction of Unified Control and Operation System for the Efficient Operation of Bimodal Tram (바이모달트램의 효율적 운용을 위한 통합관제시스템 구축에 관한 연구)

  • Lee, Kang-Won;Yun, Hee-Tek;Park, Young-Kon;Kil, Gun-Kuk;Oh, Jae-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.633-637
    • /
    • 2007
  • Bimodal Tram is the newly developed vehicle for both the tracked way and the public road. Its operation system has some characteristics including BIS(bus information system)/BMS(bus management system) based on ITS(intelligent Transportation system) which is used presently in public transportation operation system. One of them is more accurate vehicle fleet control based on both magnetic maker position reference system and GPS(global positioning system) and the other is automatic vehicle control for emergency situations by the Bimodal Tram operation system which will be performed by the unified control and operation center. This paper has investigated the requirements and functional definitions necessary to construct the unified control and operation center for Bimodal Tram operation system which will be more efficient and secure public transportation system than the conventional ones.

  • PDF

Numerical Analysis of Flow Characteristic of Residual Gas due to Changes in Valve Timings during an Idle Operation in an SI Engine (가솔린 기관의 공회전 시 밸브 타이밍 변경에 따른 잔류가스 유동 변화에 관한 해석적 연구)

  • Lee, Joon-Ho;Kim, Duk-Sang;Baik, Doo-Sung;Cho, Yong-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.50-56
    • /
    • 2006
  • Residual gas fraction in a combustion process is very crucial to improve combustion and cyclic variations. Especially, the residual gas fraction is strongly affected by backflow of the residual gas during the valve overlap period in an idle operation. Therefore, it is one of the most interesting that valve timings can affect flow characteristics of gas exchange process, especially during idle operation. This analysis investigates residual gas fraction with respect to valve timing changes which is critical for combustion efficiency and engine performance. Flow characteristics of residual gas by changing intake and exhaust valve timing are calculated by CFD methodology during an idle operation in an SI engine. It is analyzed that retarded EVO and advanced IVO results in the increase of valve overlap period and consequently, residual gas fraction. Futhermore, changes in IVO have stronger effects on variation of residual gas fraction.