• 제목/요약/키워드: Operation Characteristics

검색결과 7,668건 처리시간 0.033초

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

FARE Device Operational Characteristics of Remote Controlled Fuelling Machine at Wolsong NPP

  • I. Namgung;Lee, S.K.;Kim, Y.B.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.468-481
    • /
    • 2002
  • There are 4 CANDU6 type reactors operating at Wolsong site. For fuelling operation of certain fuel channels (with flow less than 21.5 kg/s) a FARE flow Assist Ram Extension) device is used. During the refuelling operation, two remote controlled F/Ms (Fuelling Machines) are attached to a designated fuel channel and carry out refuelling job. The upstream F/M inserts new fuel bundles into the fuel channel while the downstream F/M discharges spent fuel bundles. In order to assist fuelling operation of channels that has lower coolant How rate, the FARE device is used instead of F/M C-ram to push the fuel bundle string. The FARE device is essentially a How restricting element that produces enough drag force to push the fuel bundle string toward downstream F/M. Channels that require the use of FARE device for refuelling are located along the outside perimeter of reactor. This paper presents the FARE device design feature, steady state hydraulic and operational characteristics and behavior of the device when coupled with fuel bundle string during fuelling operation. The study showed that the steady state performance of FARE device meets the design objective that was confirmed by downstream F/M C-ram force to be positive.

테일홴 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.

고탁도시 DAF 정수장의 운영 및 진단 (Operation and Diagnosis of DAF Water Treatment Plant at Highly Turbid Raw Water)

  • 권순범;안효원;강준구;손병용
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.191-200
    • /
    • 2004
  • DAF process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when the freshwater blooms occut or raw water turbidity become high. Pre-sedimentation iS prepared in case when raw water turbidity is very high by rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while it is difficult to remove in sedimentation. One of the main concerns in adoption of DAF (Dissolved Air-Flotation) process is a high raw water turbidity problem. That is, DAF is not adequate for raw water, which is more turbid than 100NTU. In order to avoid this problem, pre-sedimentation basins are prepared in DAF plant to decrease the turbidity of DAF influent. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, DAF process coupled with sedimentation is suggested that pre-sedimentation with optimum coagulation prior to DAF would be appropriate.

A Study on Optimal Operation Strategy for Mild Hybrid Electric Vehicle Based on Hybrid Energy Storage System

  • Bae, SunHo;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.631-636
    • /
    • 2018
  • This paper proposed an optimal operation strategy for a hybrid energy storage system (HESS) with a lithium-ion battery and lead-acid battery for mild hybrid electric vehicles (mild HEVs). The proposed mild HEV system is targeted to mount the electric motor and the battery to a conventional internal combustion engine vehicle. Because the proposed mild HEV includes the motor and energy storage device of small capacity, the system focuses on low system cost and small size. To overcome these limitations, it is necessary to use a lead acid battery which is used for a vehicle. Thus, it is possible to use more energy using HESS with a lithium battery and a lead storage battery. The HESS, which combines the lithium-ion battery and the secondary battery in parallel, can achieve better performance by using the two types of energy storage systems with different characteristics. However, the system requires an operation strategy because accurate and selective control of the batteries for each situation is necessary. In this paper, an optimal operation strategy is proposed considering characteristics of each energy storage system, state-of-charge (SOC), bidirectional converters, the desired output power, and driving conditions in the mild HEV system. The performance of the proposed system is evaluated through several case studies with respect to energy capacity, SOC, battery characteristic, and system efficiency.

인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구 (Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump)

  • 박병권;서동남;엄유식;권영철;고국원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

Transition Control of Standby and Operation Modes of Wireless Charging System for Inspection Robots

  • Liu, Han;Tan, Linlin;Huang, Xueliang;Czarkowski, Dariusz
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.691-701
    • /
    • 2019
  • To solve the problems in the contact charging of inspection robots, a wireless charging system for inspection robots and a control strategy are introduced in this paper. Circuit models of a wireless power system with a compound compensation circuit and a three-phase Class-D resonant inverter are set up based on circuit theory. An output voltage control method based on the equal spread regulation of the phase difference between adjacent phases and the parameter correction method in the primary compound compensation circuit are proposed. The dynamic characteristics of the key parameters varying with the secondary coil position are obtained to further investigate the adaptive location scheme during the access and exit processes of moving robots. Combining the output voltage control method and the adaptive location scheme, a transition control strategy for the standby and operation modes of the wireless charging systems for inspection robots is put forward to realize the system characteristics including the low standby power in the standby mode and the high receiving power in the operation mode. Finally, experiments are designed and conducted to verify the correctness of the theoretical research.

도시화율 및 산업 구성 차이에 따른 딥러닝 기반 전력 수요 변동 예측 및 전력망 운영 (Deep Learning Based Electricity Demand Prediction and Power Grid Operation according to Urbanization Rate and Industrial Differences)

  • 김가영;이상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.591-597
    • /
    • 2022
  • Recently, technologies for efficient power grid operation have become important due to climate change. For this reason, predicting power demand using deep learning is being considered, and it is necessary to understand the influence of characteristics of each region, industrial structure, and climate. This study analyzed the power demand of New Jersey in US, with a high urbanization rate and a large service industry, and West Virginia in US, a low urbanization rate and a large coal, energy, and chemical industries. Using recurrent neural network algorithm, the power demand from January 2020 to August 2022 was learned, and the daily and weekly power demand was predicted. In addition, the power grid operation based on the power demand forecast was discussed. Unlike previous studies that have focused on the deep learning algorithm itself, this study analyzes the regional power demand characteristics and deep learning algorithm application, and power grid operation strategy.

상용 개질촉매의 중온 영역 운전 특성: Ru 촉매와 Ni 촉매 비교 (Mid-Temperature Operation Characteristics of Commercial Reforming Catalysts: Comparison of Ru-Based and Ni-Based Catalyst)

  • 김영상;이강훈;이동근;이영덕;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제32권3호
    • /
    • pp.149-155
    • /
    • 2021
  • Most of the reformer experiments have been conducted only in high-temperature operation conditions above 700℃. However, to design high efficiency solid oxide fuel cell, it is necessary to test actual reaction performance in mid-temperature (550℃) operation areas. In order to study the operation characteristics and performance of commercial reforming catalysts, a reforming performance experiment was conducted on mid-temperature. The catalysts used in this study are Ni-based FCR-4 and Ru-based RuA, RuAL. Experiments were conducted with a Steam-to-carbon ratio of 2.0 to 3.0 under gas hourly space velocity (GHSV) 2,000 to 5,000 hr-1. As a result, RuA and RuAL catalysts showed similar gas composition to the equilibrium regardless of the reforming temperature. However, the FCR-4 catalyst showed a lower hydrogen yield compared to the equilibrium under high GHSV conditions.

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.