• Title/Summary/Keyword: Operation Characteristics

Search Result 7,664, Processing Time 0.031 seconds

Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration (메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석)

  • Cho, Chang-Hwan;Kim, Yong-Chan;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.

High Temperature Characteristics of SOI BMFET (SOI BMFET 의 고온 특성 분석)

  • Lim, Moo-Sup;Kim, Seoung-Dong;Han, Min-Koo;Choi, Yearn-Ik
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1579-1581
    • /
    • 1996
  • The high temperature characteristics of SOI BMFET are analyzed by the numerical simulation and compared with MOS-gated SOI power devices at high temperatures. The proposed SOI BMFET combines bipolar operation in the on-state with unipolar FET operation in the off-state, so that it may be suitable for high temperature operation without any significant degradation of performance such as the leakage current and blocking capability. The simulation results show that SOI BMFET with a higher doped n-resurf layer is the most promising device far high temperature application as compared with MOS-gated SOI power devices, exhibiting the low on-state voltage drop as well as the excellent forward blocking capability at high temperature.

  • PDF

LOAD CHARACTERISTICS OF ROTARY OPERATION BY TRACTOR IN WET PADDY FIELDS

  • Y. G. Wu;Kim, K. U.;Y. K. Jung
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.101-108
    • /
    • 2000
  • The torque loads were measured at the input shaft of the transmission and driving shaft of the tractor having a cage wheel attached to the driving tires as a traction aid during. a rotavating operation in wet paddy fields with deep hardpan. Their load spectra were also calculated. Effects of design parameters of the cage wheel on the load characteristics were analyzed. The torque load exerted on the input shaft decreased as diameter of the cage wheel increased and increased as the rotating speed of the rotavator increased. The torque load exerted on the driving shaft increased as the working speed of the tractor increased and decreased as the PTO speed increased. Both the torque loads with the cage wheel were greater than those without the cage wheel. The cage wheel was developed for this study.

  • PDF

Operation Principle and Characteristics Simulation of STATCOM (무효전력보상장치(STATCOM)의 동작원리 및 특성 시뮬레이션)

  • Lee, Dong-Ju;Lee, Eun-Woong;Lee, Jong-Han;Kim, Jong-Gyeum
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.58-60
    • /
    • 2005
  • STATCOM whose performance is higher than SVC at a view point of a continuous controllability of reactive power and response time is reviewed in this paper. Also, basic principle of STATCOM operation and the functions of each component are explained. 30kVA STATCOM system is practically designed according to design procedure in reference [2, [7] to develop a cost-effective and compact compensator. Its operation characteristics are verified by the simulation.

  • PDF

A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation (불평형 전압 운전시의 역률보상용 커패시터 특성 연구)

  • Kim, Il-Jung;Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

Design and operation of the oxygen system (산소 시스템의 설계와 운용)

  • Lim, Ha-Young;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.51-54
    • /
    • 2010
  • Physical characteristics of liquid and gaseous oxygen and the detailed ignition characteristics of oxygen system were introduced. Compatible and non-compatible materials for oxygen were discussed. To ensure the safety operation of the oxygen system, one of the most important point, cleaning, was reviewed. To design the gaseous and liquid oxygen system, key points were introduced. To safe operation, the operating procedure and considerations were introduced.

  • PDF

Life Comparision of 2$\frac{1}{2}$ Ton Truck Considering The Operation Terrains (운행지형형태에 따른 2$\frac{1}{2}$톤 트럭의 수명비교)

  • Kim Jang-Hyeon;Ha Seok-Tae
    • Journal of the military operations research society of Korea
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1990
  • The life of an equipment depends upon its operating characteristics and physical environment factors. This paper presents the economic life length of 2 1/2 ton truck considering the operation terrains. For this specific research, the operation terrains are categorized into seacoast area, mountain area and plain area. To compute the life length, the method of equivalent annual cost is employed. The sample vehicles from each corresponding area are randomly selected from those vehicles whose ages exceed 9 years. This research finds the following results : (1) The life length operated at seacoast area is 9.75 years, (2) The life length operated at mountain area is 11.25 years, (3) The life length operated at plain area is 14 years. This research argues that the key factor such as characteristics of operating enviroment for allocation of operating and maintaining cost should be considered.

  • PDF

Improved Phase-shift Pulse-width Modulation Full-bridge Converter using a Blocking Capacitor (블로킹커패시터를 이용한 향상된 위상천이 펄스폭변조 풀브리지 컨버터)

  • Jeong, Gang-Youl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.20-29
    • /
    • 2011
  • This paper presents an improved phase-shift pulse-width modulation (PWM) full-bridge converter using a blocking capacitor. As the proposed converter reduces the circulation energy by inserting only one series blocking capacitor at the primary side of the conventional phase-shift PWM full-bridge converter structure, it improves the operation characteristics of the conventional converter. In this paper, first, the operation of conventional phase-shift PWM full-bridge converter is roughly reviewed, and then the operational principle of the proposed converter is classified and explained by each mode. After that, a prototype design example based on the operational principle is shown. Then, the improved operation characteristics of the proposed converter are actually verified through the experimental results.

A Study on Protection system to the Load Characteristics on the AC Feeder System (부하 특성에 따른 교류 급전시스템에서의 보호방식 연구)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim joorak
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

Analysis on the Operation Characteristics of Induction Motor Operated by Asymmetric Unbalanced Voltage (비대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Sohn, Hong-Kwan;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.58-64
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance is a condition in a polyphase system in which the rms values of the line-to-line voltages or the phase angles between consecutive line-to-line voltages, are not all equal. Slight voltage unbalance generates a disproportionately high current unbalance at the motor stator winding. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.