• Title/Summary/Keyword: Operating value of sensor

Search Result 60, Processing Time 0.023 seconds

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke: a retrospective study

  • Lim, Seung-yeop;Lee, Byung-jun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.2
    • /
    • pp.54-60
    • /
    • 2018
  • Objective: Persons with chronic stroke fall more often than healthy elderly individuals. The Timed Up and Go test (TUG) is used as a fall prediction tool, but only provides a result for the total measurement time. This study aimed to determine the optimal cut-off values for each of the 6 components of the TUG. Design: Retrospective study. Methods: Thirty persons with chronic stroke participated in the study. TUG evaluation was performed using a wearable miniaturized inertial sensor. Sensitivity, specificity, and predictive values were calculated using the Receiver Operating Characteristic (ROC) curve analysis for the measured values in each section. Optimal values for fall risk classification were determined. Logistic regression analysis was used to investigate the risk of future falls based on TUG. Results: The cut-off values of the 6 sections of the TUG were determined, as follows: sit-to-stand >2.00 seconds (p<0.05), forward gait >4.68 seconds (p<0.05), mid-turn >3.82 seconds (p<0.05), return gait >4.81 seconds (p<0.05), end-turn >2.95 seconds (p<0.05), and stand-to-sit >2.13 seconds (p<0.05). The risk of falling increased by 2.278 times when the mid-turn value was >3.82 seconds (p<0.05). Conclusions: The risk of falls increased by 2.28 times when the value of the mid-turn interval exceeded 3.82 seconds. Therefore, when interpreting TUG results, the predictive accuracy for falls will be higher when the measurement time for each section is analyzed, together with the total time for TUG.

Development of a Salt Taste Sensor for Improvement on Meal HabitDirection Method (식습관 개선을 위한 음식 짠맛센서 개발)

  • Yang, Gil-Mo;Seo, In-Ho;Kim, Gi-Young;Lee, Kang-Jin;Son, Jae-Yong;Mo, Chang-Yeon;Kim, Yong-Hoon;Park, Saet-Byoul
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.310-315
    • /
    • 2010
  • The amount of salt intake of Korean people is 11.4 grams per a day, which is 2.3 times of the recommended daily salt intake by WHO - 5 grams of salt a day. The relationship between high salt consumption and increased risk of high blood pressure, observed not only in hypertensive but also in normotensive patients. High salt intake is also associated with an increased risk of heart attack, cerebral ischemia and osteoporosis. Therefore, this research is for developing a salt taste sensor to reduce sodium consumption and improve meal habits for the perception of a more bland taste of most foods. When the sensor was put into food sample, current intensity achieved with distribution cables. Current intensity was correlate with a simple equivalent of salt taste stimulus intensity. The salt taste sensor consists of salinity & temperature measuring probe, signal processing circuit and LCD display & LED warning light. When salinity is going over a set point, LCD displayer indicate salt taste on LCD panel by percent value (%), and at the same time, blue LED light change to red LED light. So we could know the grade of salt taste in soup before meals conveniently and objectively. The results show that operating range of 10 to $80^{\circ}C$ and accuracy of ${\pm}0.1%$ were achieved with an analysis time of about 2 or 3 sec. Moderate reductions in salt intake can help to avert adult diseases and lead a healthy life.

Characteristics of metal-loaded TiO2/SnO2 thick film gas sensor for detecting acetonitrile (아세토나이트릴 가스 검지를 위한 센스의 제작 및 특성)

  • Park, Young-Ho;Lee, Chang-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 2009
  • This study investigated sensitivity of the gas sensor to chemical weapons with the sensor material doped with catalysts. The nano-sized SnO2 powder mixed with metal oxides (TiO2) was doped with transition metals(Pt, Pd and In). Thick film of nano-sized SnO2 powder with TiO2 was prepared by screen-printing method onto Al2O3 substrates with platinum electrode and chemical precipitation method. The physical and chemical properties of sensor material were investigated by SEM/EDS, XRD and BET analyzers. The measured sensitivity to simulant toxic gas is defined as the percentage of resistance of value equation, [(Ra-Rg)/$Ra\;{\times}100$)], that of the resistance(Ra) of SnO2 film in air and the resistance(Rg) of SnO2 film in acetonitrile gas. The best sensitivity and selectivity of these thick film were shown with 1wt.% Pd and 1wt.% TiO2 for acetonitile gas at the operating temperature of $250^{\circ}C$.

  • PDF

Construction of Current Sensor Using Hall Sensor and Magnetic Core for the Electric and Hybrid Vehicle (홀소자와 자기코어를 이용한 하이브리드 및 전기자동차용 전류센서 제작)

  • Yeon, Kyoheum;Kim, Sidong;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.49-53
    • /
    • 2013
  • A current sensor is one of important component which is used for the electrical current measurement during charge and discharge of the battery, and monitoring system of the motor controller in the electric and hybrid vehicle. In this study, we have developed an open loop type current sensor using GaAs Hall sensor and magnetic core has an air gap. The Hall sensor detect magnetic field produced by the current to be measured. The 3 mm air gap core was made by HGO electrical steel sheets after slitting, winding, annealing, molding, and cutting. Developed current sensor shows 0.03 % linearity within DC current range from -400 A to +400 A. Operating temperature range was extended to the range of $-40{\sim}105^{\circ}C$ using temperature compensating electronic circuit. To Improve frequency bandwidth limit due to the air flux of PCB (Printed Circuit Board) and Hall sensor, We employed an air flux compensating loop near Hall sensor or on PCB. Frequency bandwidth of the sensor was 100 kHz when we applied sine wave current of $40A{\cdot}turn$ in the frequency range from 100 Hz to 100 kHz. For the dynamic response time measurement, 5 kHz square wave current of $40A{\cdot}turn$ was applied to the sensor. Response time was calculated time reach to 90 % of saturation value and smaller than $2{\mu}s$.

A Study on the Implementation of SoC for Sensing Bio Signal (인체신호 측정을 위한 SoC 구현에 관한 연구)

  • Sun, Hye-Seung;Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.109-114
    • /
    • 2010
  • In this paper, the implementation of a human signal sensing module that has capabilities to check and restore the weak signals from the human body is presented. A module presented in this paper consists of processing and sensing elements related to human pulse and body temperature and a controller implemented with SoC design method. PPG data is detected by a noise filtering process toward the amplified signal which is from the operating frequency between 0.1Hz - 10Hz. A digital temperature sensor is used to check the body temperature. A sensor outputs the corresponding value of the electric voltage according to the body temperature. Moreover, this paper discusses the implementation of an enhanced microprocessor which is synthesized with VHDL as a part of the SoC development and used to control the entire module. The SoC processor is implemented on a Xilinx Spartan 3 XC3S1000 device and has the achieved operating frequency of 10MHz. The implemented SoC processor core is successfully tested with macro memories in FPGA and the experimental results are hereby shown.

$CO_{2}$ sensing characteristics of solid electrolyte gas sensor with the sensing membrane prepared by the mixture of alkali metal carbonate and binder (알카리 금속 탄산염과 결착제의 혼합물을 감지물질로 하는 고체전해질 가스센서의 $CO_{2}$ 감응 특성)

  • Chai, Yu-Sug;Song, Kap-Duk;Kang, Bong-Hwi;Seo, Moo-Gyo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.111-116
    • /
    • 1998
  • The simple solid electrolyte carbon dioxide sensor with heaters were fabricated by using Li ionic conductor. Two Au electrodes were used for the reference and sensing electrode respectively. Two types of gas sensors, type ( I ) and type (II), were fabricated. Type ( I ) sensor was fabricated by the method of melting and crystallizing alkali metal carbonate at the temperature of $420{\sim}500^{\circ}C$. The sensing membrane of type (II) sensor was formed by the printing method on sensing electrode after metal carbonate was mixed with binder. The response characteristics of sensors fabricated for the carbon dioxide were investigated for a range of $CO_{2}$ concentration from 950 ppm to 9,950 ppm at operating temperature $420^{\circ}C$. Type ( I ) sensor and type (II) sensor showed the sensitivity of 62 mV/decade and 65 mV/decade respectively. The emf/decade of type (II) sensor tested at $420^{\circ}C$ almost followed the theoretical value of Nernst's equation and showed stable response characteristics with the fast response time of $15{\sim}20$ sec. Also type (II) sensor showed excellent stability and reproduction properties for 60 days.

  • PDF

Capacitance Estimation of DC-Link Capacitor Considering Temperature Effect

  • Pu, Xingsi;Kim, Kyung-Hyun;Lee, Dong-Choon;Lee, Kyo-Beom;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.156-157
    • /
    • 2010
  • This paper proposes a correction method of capacitance estimation considering the temperature effect for the DC-link capacitor banks in three-phase AC/DC PWM converters. In this work, a sensing circuit using a temperature sensor is designed for measuring the operating temperature. Capacitance value is corrected considering the measured temperature. This method has been implemented in experiment.

  • PDF

Hysteresis Reduction in piezoelectric actuator by a charge control method (전하 제어법을 이용한 압전 액추에이터의 이력저감)

  • Jeong Soonjong;Lee Daesu;Song Jaesung;Hong Younpyo;Kang Eungu;Choi Wonjong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.35-39
    • /
    • 2005
  • This paper presents a method to reduce hysteresis in multilayer ceramic actuator by connecting the actuator with a capacitor in a series circuit. The change in hysteresis with respect to the capacitor was examined. $0.2Pb(Mg_{1/3}Nb_{2/3})O_3-0.8Pb(Zr_{0.475}Ti_{0.525})O_3$ ceramic material was used as a piezoelectric material for the actuator. Displacement of the actuator was measured in a capacitive gap sensor measuring system. In case of inserting a capacitor in a total circuit, hysteresis became dramatically decreased, and then finally the hysteresis value can be reduced below $0.2\%$. It was found in this present study that reducing the hysteresis in the actuator is dependent upon the characteristics of the capacitor in total circuit and also operating frequency.

  • PDF

Development of Underwater Wide-band Acoustic Transducer Using the 1-3 Piezoelectric Composite (1-3형 압전복합체를 이용한 광대역 수중 음향 트랜스듀서 개발)

  • Lee, Kyung-Woo;So, Hyoung-Jong;Lim, Sil-Mook;Kim, Won-Ho;Kim, Dae-Yun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.424-431
    • /
    • 2008
  • Recently, it is required that acoustic transducers for underwater detection and communication sensor have wide bandwidth and low operating frequency. In this research, the new acoustic transducer is proposed. This transducer is tonpilz type, and made of 1-3 piezoelectric composites as a driving parts. The developed transducer is evaluated the TVR(transmission voltage response) and RVS(receiving voltage sensitivity) characteristics around $4{\sim}14\;kHz$ frequency range and is compared to conventional tonpilz transducer made of solid piezoelectric ceramics as a driving parts. The resonance frequency of the developed transducer is decreased by 30% and the -3 dB bandwidth is increased by 90%, compared to conventional transducer with same dimensions. The value of TVR is decreased by 9 dB and The value of RVS is the same at resonance frequency.