• Title/Summary/Keyword: Operating time delay

Search Result 212, Processing Time 0.026 seconds

Flexible Real Time Embedded System Using RTOS and SOPC (RTOS와 SOPC를 이용한 유연한 실시간 처리 임베디드시스템)

  • Ahn, Sang-Min;Choi, Woo-Chang;Kong, Jung-Shik;Lee, Bo-Hee;Kim, Jin-Geol;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2843-2845
    • /
    • 2005
  • This paper deals with the design of real-time embedded system using RTOS (real-time operating system) and SOPC (system on a programmable chip). It is, in general, known that RTOS has the problem of time delay caused by the multiple tasks and task management approach. Since the increase in time delay in real-time embedded system makes the overall system have the poor performance or the critical behavior of instability and unreliability, the method employed RTOS and SOPC is proposed to attack the above problems. The proposed system is implemented on the RC-motor controller and is verified by real experiment.

  • PDF

Time Delay Limit of Over Current Relay for Maintaining Stability in Industrial Power Systems (산업용 전력계통의 안정도 유지를 위한 과전류계전기의 시간지연 한계)

  • Kim, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.190-192
    • /
    • 2002
  • The industrial power distribution system is a radial system and therefore usually protected with time delayed over current relays (OCR's). Proper time dial settings are provided at the OCR's. Meanwhile, the systems, where synchronous generator, or synchronous motors, or large induction motors are operating, can not be protected with only OCR's with time grading. This paper presents a technical limit and a suitable range of time delay in applying OCR's to clearing faults in the industrial power systems for maintaining stability. Dynamic simulations are made to show them employing a real power systems of a large petro-chemical complex.

  • PDF

A Study on the Traffic Effect Zone and Application of Road Occupying Construction (도로 공사중의 교통영향권역 설정 및 적용성에 관한 연구)

  • Lee, Ju-Ho;Lee, Young-Woo;Lim, Chae-Moon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.2
    • /
    • pp.131-139
    • /
    • 2003
  • The links operating interrupted flow are intend to yield the traffic between the out flow and inflow part effect zone of street section, we build the delay model using the time gap between under construction and not. We review the applicability of interrupted flow, and thus we can put this data to practical use as the basis data to compute the inducement charge for traffic delay. Also building about traffic effect zone of interrupted flow wouldn't produce at the section beside occupying roads and construction cross section, thus we must review the plan to minimize traffic delay by the construction occupying road. In future there must be advanced the incomplete in this study, and groping for the various alternatives to minimize the traffic delay by the road occupying construction, with developing the various sets of detailed analyzing models, that is analysis on the street strength, crossroads geometrical forms of crossroads, public traffics, pedestrians, occupying types.

  • PDF

Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission (자동변속기 마찰요소의 동특성 해석)

  • 최영종;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

Measurement and Prediction of Autoignition Temperature of n-Propanol+n-Decane Mixture (노말프로판올과 노말데칸 혼합물의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.55-61
    • /
    • 2014
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the substance will spontaneously ignite in the absence of an external ignition source such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for processs safety. This study measured the AITs of n-Propanol+n-Decane system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-Propanol and n-Decane which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-Propanol+n-Decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D(average absolute deviation).

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

Analysis of Operational Availability under Changing Failure Rate and Supportability (무기체계의 고장률과 지원수준의 변화에 따른 운용가용도 변화 분석)

  • Tak, Jung Ho;Jung, Won
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Purpose: Maintaining appropriate operational availability (Ao) is a key element of combat victory, but estimates vary according to estimation methods. The purpose of this study is to improve the accuracy of estimating operational availability by tracing the changes of the weapon system's failure rate, repair rate, and the level of logistic support. Methods: In order to track the change in the operating availability, the MDT (mean down time) is modeled by adding the repair time and the ALDT (administration and logistic delay time) to the service time. Results: Using the field data of the weapon system A operated by the ROKAF, the failure rate follows a non-homogeneous Poisson process that changes with time, and it is modeled considering the changing repair rate and the logistic support time. Conclusion: The accuracy of the analytical results was verified by comparing the actual operating data with the estimated availability. The results of this study can be used to track and evaluate the availability in a realistic situation where the failure rate and maintenance rate continuously change in operating environment.

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

A Study on the Control technique of the Real-Time over the Environment of Graphic User Interface Using VxD. (VxD를 이용한 GUI환경에서의 실시간 제어기법에 관한 연구)

  • 장성욱;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.120-120
    • /
    • 2000
  • In this study, in order to control real system under the environment of graphic user interface, study on the technique which can control real system without additional hardware drivers using virtual machine driver operated on the windows operating system. Consider the problem which is the error and the delay of a sampling time on the multi task processing through the load test of the experiment using graphic user interface.

  • PDF