• 제목/요약/키워드: Operating limit

검색결과 522건 처리시간 0.029초

Dose evaluation of workers according to operating time and outflow rate in a spent resin treatment facility

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3824-3836
    • /
    • 2021
  • Workers' safety from radiological exposure in a 1 ton/day capacity spent resin treatment facility was evaluated according to the operating times and outflow rate due to process related leakages. The conservative annual dose based on the operating times of the workers exceeded the dose limit by at least 7.38E+01 mSv for close work. The realistic dose range was derived as 1.62E+01 mSv-6.60E+01 mSv. The conservative and realistic annual doses for remote workers were 1.33E+01 mSv and 3.00E+00 mSv respectively, which were less than the dose limit. The MWR was identified as the major contributor to worker exposure within the 1 h period required for removal of radioactive materials. The dose considering both internal and external exposures without APF was derived to be 1.92E+01 mSv for conservative evaluation and 4.00E+00 mSv for realistic evaluation. Furthermore, the dose with APF was derived as 7.27E-01 mSv for conservative evaluation and 1.51E-01 mSv for realistic evaluation. Considering the APF for leakage from all parts, the dose range was derived as 1.25E+00 mSv-2.03E+00 mSv for conservative evaluation and 2.61E-01 mSv-4.23E-01 mSv for realistic evaluation. Hence, it was confirmed that radiological safety was secured in the event of a leakage accident.

가변속도제한시스템의 제한속도 결정을 위한 UTIS 정보와 기상정보 연계방안 (Integration of UTIS and WIS information for Determining Speed Limits of Variable Speed Limit System)

  • 손현호;이철기;이상수;윤일수
    • 한국ITS학회 논문지
    • /
    • 제11권6호
    • /
    • pp.111-122
    • /
    • 2012
  • 교통관련 시스템의 다변화로 기존 ITS시스템을 활용하여 다양한 응용 서비스를 제공하기 위한 필요성이 대두되고 있으며 그 중 UTIS를 활용한 다양한 부가 서비스를 제공하기 위한 연구가 진행 중이다. 본 연구에서는 UTIS의 실시간 교통정보와 기상정보 수집 시스템을 활용한 가변속도제한 시스템 연계방안에 관한 연구를 하였다. 본 시스템을 연계 운영하는 방안으로 기상정보 데이터를 이용하여 적정한 가변속도를 산출하는 방법, UTIS 정보를 이용하여 산출하는 방법 그리고 기상정보와 UTIS의 소통정보에 기상에 따른 가중치를 부여하여 감속도를 산출하는 3가지의 방법에 관하여 연구 하였다. 가장 적합한 감속도를 구하기 위해 통행속도와 노면마찰계수, 종방향 편경사를 이용해 조건에 따라서 변화되는 자동차의 최소정지거리를 산정하는 방법을 이용하였으며 최소정지거리와 운행속도의 관계를 이용하여 최종적으로 필요한 속도를 산출하였다.

효율적인 센서 운영체제를 위한 실시간 인터럽트 처리 기법 (A Real-time Interrupt Handling Scheme for Efficient Sensor Operating Systems)

  • 안재훈;최규호;김태형;홍지만
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권4호
    • /
    • pp.437-441
    • /
    • 2010
  • 무선 센서 네트워크가 적용되는 새로운 응용분야는 점점 더 정교하고 복잡한 태스크 수행과 정해진 시간내에 태스크 수행을 완료해야 한다는 조건 만족을 요구하고 있다. 그러나 현재까지, 무선 센서 네트워크에서 센서 노드의 자원 제약성과 수행 작업 특성을 고려한 실시간 센서 운영체제 기반의 인터럽트 처리 기법에 관한 연구는 미비하다. 본 논문에서는 센서 운영체제에서 실시간성을 만족시키기 위한 요구 사항들을 분석하고, 이를 바탕으로 시스템을 설계 및 구현한다. 또한 다양한 검증을 통해, 제안하는 기법의 신뢰성 제공을 확인하며, 시뮬레이션을 통해 실시간 특성에 대한 요구사항 충족 및 성능의 효율성을 검증한다.

가역 루프 히트파이프의 작동특성에 관한 실험적 연구 (An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe)

  • 김봉훈;최준민
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성 (Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors)

  • 정의국;부준홍;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

Concept Development of a Simplified FPGA based CPCS for Optimizing the Operating Margin for I-SMRs

  • Randiki, Francis;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제17권2호
    • /
    • pp.49-60
    • /
    • 2021
  • The Core Protection Calculator System (CPCS) is vital for plant safety as it ensures the required Specified Acceptance Fuel Design Limit (SAFDL) are not exceeded. The CPCS generates trip signals when Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) exceeds their predetermined setpoints. These setpoints are established based on the operating margin from the analysis that produces the SAFDL values. The goal of this research is to create a simplified CPCS that optimizes operating margin for I-SMRs. Because the I-SMR is compact in design, instrumentation placement is a challenge, as it is with Ex-core detectors and RCP instrumentation. The proposed CPCS addresses the issue of power flux measurement with In-Core Instrumentation (ICI), while flow measurement is handled with differential pressure transmitters between Steam Generators (SG). Simplification of CPCS is based on a Look-Up-Table (LUT) for determining the CEA groups' position. However, simplification brings approximations that result in a loss of operational margin, which necessitates compensation. Appropriate compensation is performed based on the result of analysis. FPGAs (Field Programmable Gate Arrays) are presented as a way to compensate for the inadequacies of current systems by providing faster execution speeds and a lower Common Cause Failure rate (CCF).

교통량과 제한속도에 따른 간선도로 속도 변화에 관한 연구 (A Study on the Speed Change on the Arterial Road according to Traffic Volume and Speed Limit)

  • 신언교;김주현
    • 한국ITS학회 논문지
    • /
    • 제21권5호
    • /
    • pp.149-161
    • /
    • 2022
  • 제한속도는 주행속도에 영향을 주기 때문에 교통흐름은 물론 교통사고와도 밀접한 관계에 있다. 기존 제한속도 산정 방법은 공학적 판단요소로 차로수, 교차로 간격, 진출입로 수, 횡단보도 수, 85백분위 속도, 토지이용 형태, 도로기하 특성 등 다양한 요소들을 고려하지만 대부분이 교통시설에 해당되고 교통량을 고려한 교통영향분석이 이루어지지 않고 있어 공학적 분석이 미흡하다고 할 수 있다. 또한 지점속도인 85%속도만으로는 도로 전체의 교통류 특성을 잘 반영해주지 못한다. 따라서 본 논문에서는 교차로 간격과 교통량 조건에서 제한속도 변화가 순행속도와 통행속도의 크기와 그 차이에 미치는 영향을 상세하게 분석하였다. 그리고 그 결과를 활용하여 제한속도 변경 전과 동일한 서비스수준을 유지토록 하여 속도개선효과를 높이고 순행속도와 통행속도의 차이를 줄이는 제한속도 산정방안을 제안하였다. 그리고 교통량 변화에 따른 가변적 제한속도 운영방안도 제시하였다. 본 방안은 속도개선효과를 확보하면서 교통사고 심각도에 영향을 주는 속도 차이를 줄이고 교통량 변화에 따른 주행속도 변화를 반영한 제한속도 운영으로 운전자들의 제한속도 준수율을 높여 안전측면에서도 효과가 기대된다.

한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구 (Study on Local Buckling of District Heating Pipes Using Limit State Design)

  • 김주용;이상연;고현일;조종두
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1829-1836
    • /
    • 2010
  • 지역난방은 열병합 발전소에서 생산된 열을 온수의 형태로 열배관 네트워크를 통해 넓은 지역에 일괄적으로 공급하는 난방시스템이다. 일반적으로 지역난방 열배관은 지중에 매설되며 내부를 흐르는 온수의 압력과 온도변화, 매설 토사와의 마찰 및 반력에 의한 하중을 받게 되므로 열공급 효율과 함께 기계적인 안전성에 대한 검토가 반드시 필요하다. 본 논문에서는 강관의 한계상태 설계법을 이용하여 한계판폭두께비와 한계변형률, 두 가지 관점에서 열배관의 국부좌굴 발생여부를 평가하였으며 그 결과 현재 국내에서 사용되고 있는 모든 열배관은 국부좌굴이 발생하지 않음을 확인하였다. 마지막으로 국부좌굴을 피하기 위한 최소 예열온도를 산출함으로써 예열온도에 대한 시공 기준을 제시하였다.

원주방향 표면 결함이 존재하는 배관에 가해지는 비틀림을 포함한 복합하중에 대한 한계하중식 제시 (Evaluation of Limit Loads for Circumferentially Cracked Pipes Under Combined Loadings)

  • 류호완;한재준;김윤재
    • 대한기계학회논문집A
    • /
    • 제39권5호
    • /
    • pp.453-460
    • /
    • 2015
  • 후쿠시마 원전 사고 이후로 원자력 발전 플랜트의 배관 시스템에 가해지는 비틀림 하중의 영향에 대한 연구가 여러 연구자들에 의해서 수행되었다. 발전 플랜트의 원주방향 균열을 포함한 배관은 정상운전 조건이나 갑자기 발생한 사고에 의해서 굽힘과 비틀림과 같은 하중을 받을 수 있다. ASME 코드에서는 균열 배관의 구조건전성 확보를 위해서 한계하중 기법을 사용해서 완전소성 파단에 대한 결함평가를 제공한다. 최근 개정된 코드에 따르면, 복합하중은 막응력과 굽힘 응력만을 포함하고 있다. 실제로 운전 환경에서 비틀림 하중이 가해질 수 있음에도 불구하고, 비틀림 하중을 평가하는 방법론에 대해서는 언급하지 않았다. 본 논문에서는 한계하중 분석을 기반으로 원주방향 균열 존재하는 배관에 단순 굽힘과 단순 비틀림, 인장을 포함한 굽힘 비틀림 복합하중이 가해질 경우에 대한 유한요소해석 결과를 포함하고 있다. 전단면 완전항복 기준을 만족하는 한계하중 이론해를 제안하고 유한요소해석을 통해서 이를 검증하였다.

금강-보령댐 도수터널 운영에 따른 금강 본류 내 수위 영향 분석 연구 (Impacts on Water Surface Level of the Geum River with the Diversion Tunnel Operation for Low Flow Augmentation of the Boryong Dam)

  • 장석환;오경두;오지환
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1031-1043
    • /
    • 2017
  • Recently severe drought caused the water shortage around the western parts of Chungcheongnamdo province, South Korea. A Diversion tunnel from the Geum river to the Boryong dam, which is the water supply dam for these areas has been proposed to solve this problem. This study examined hydraulic impacts on the Geum river associated with the diversion plan assuming the severe drought condition of 2015 would persist for the simulation period of 2016. The hydraulic simulation model was verified using hydrologic and hydraulic data including hourly discharges of the Geum river and its 8 tributaries, fluctuation of tidal level at the mouth of the river, withdrawals and return flows and operation records of the Geum river barrage since Feb. 1, 2015 through May 31, 2015. For the upstream boundary condition of the Geum river predicted inflow series using the nonlinear regression equation for 2015 discharge data was used. In order to estimate the effects of uncertainty in inflow prediction to the results total four inflow series consisting of upper limit flow, expected flow, lower limit flow and instream flow were used to examine hydraulic impacts of the diversion plan. The simulation showed that in cases of upper limit and expected flows there would be no problem in taking water from the Geum river mouth with a minimum water surface level of EL(+) 1.44 m. Meanwhile, the simulation also showed that in cases of lower limit flow and instream flow there would be some problems not only in taking water for water supply from the mouth of the Geum river but also operating the diversion facility itself with minimum water surface levels of EL(+) 0.94, 0.72, 0.43, and 0.14 m for the lower limit flow without/with diversion and the instream flow without/with diversion, respectively.