• Title/Summary/Keyword: Operating limit

Search Result 518, Processing Time 0.032 seconds

Dose evaluation of workers according to operating time and outflow rate in a spent resin treatment facility

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3824-3836
    • /
    • 2021
  • Workers' safety from radiological exposure in a 1 ton/day capacity spent resin treatment facility was evaluated according to the operating times and outflow rate due to process related leakages. The conservative annual dose based on the operating times of the workers exceeded the dose limit by at least 7.38E+01 mSv for close work. The realistic dose range was derived as 1.62E+01 mSv-6.60E+01 mSv. The conservative and realistic annual doses for remote workers were 1.33E+01 mSv and 3.00E+00 mSv respectively, which were less than the dose limit. The MWR was identified as the major contributor to worker exposure within the 1 h period required for removal of radioactive materials. The dose considering both internal and external exposures without APF was derived to be 1.92E+01 mSv for conservative evaluation and 4.00E+00 mSv for realistic evaluation. Furthermore, the dose with APF was derived as 7.27E-01 mSv for conservative evaluation and 1.51E-01 mSv for realistic evaluation. Considering the APF for leakage from all parts, the dose range was derived as 1.25E+00 mSv-2.03E+00 mSv for conservative evaluation and 2.61E-01 mSv-4.23E-01 mSv for realistic evaluation. Hence, it was confirmed that radiological safety was secured in the event of a leakage accident.

Integration of UTIS and WIS information for Determining Speed Limits of Variable Speed Limit System (가변속도제한시스템의 제한속도 결정을 위한 UTIS 정보와 기상정보 연계방안)

  • Son, Hyun-Ho;Lee, Choul-Ki;Lee, Sang-Soo;Yun, Il-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.111-122
    • /
    • 2012
  • There has been a strong demand for providing diverse services to drivers utilizing existing ITS infrastructure. To this end, this study is aiming at improving the accuracy of a variable speed limit system by determining recommended speeds for the system utilizing the information from Urban Traffic Information System(UTIS) and Weather Information System(WIS). In order to determine appropriate speed limits under inclement weather conditions for the variable speed limit system, this study examined three methods: i) the method utilizing the information from WIS, ii) the method utilizing the information from UTIS, and iii) the method which combines the information from WIS and UTIS using different weights for diverse weather conditions. Finally, this study selected the third method which determines an appropriate speed limit using the relationship between the vehicle operating speed and the minimum stopping distance which is estimated using the existing speed limit, surface coefficient of friction and superelevation.

A Real-time Interrupt Handling Scheme for Efficient Sensor Operating Systems (효율적인 센서 운영체제를 위한 실시간 인터럽트 처리 기법)

  • Ahn, Jae-Hoon;Choi, Kyu-Ho;Kim, Tae-Hyung;Hong, Ji-Man
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.4
    • /
    • pp.437-441
    • /
    • 2010
  • A new application area in which wireless sensor networks are applied requires the performance of more elaborated and complicated task and the completion of those tasks within a time limit. Until now, it is, however, insufficient to do research on the mechanism of handling interrupt based on real-time sensor operating systems which carefully consider the limitation of resources of sensor nodes and the property of tasks which is executed in a wireless sensor network area. In this paper, the requirements satisfying real-time in sensor operating systems are analyzed and based on this, a system is designed and implemented. In addition, the proposed mechanisms are confirmed by several verification methods, and the efficiency of the performance and the satisfaction of those requirements for real-time are verified by simulation.

An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe (가역 루프 히트파이프의 작동특성에 관한 실험적 연구)

  • Kim Bong-Hun;Choi Joon-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors (물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

Concept Development of a Simplified FPGA based CPCS for Optimizing the Operating Margin for I-SMRs

  • Randiki, Francis;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • The Core Protection Calculator System (CPCS) is vital for plant safety as it ensures the required Specified Acceptance Fuel Design Limit (SAFDL) are not exceeded. The CPCS generates trip signals when Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) exceeds their predetermined setpoints. These setpoints are established based on the operating margin from the analysis that produces the SAFDL values. The goal of this research is to create a simplified CPCS that optimizes operating margin for I-SMRs. Because the I-SMR is compact in design, instrumentation placement is a challenge, as it is with Ex-core detectors and RCP instrumentation. The proposed CPCS addresses the issue of power flux measurement with In-Core Instrumentation (ICI), while flow measurement is handled with differential pressure transmitters between Steam Generators (SG). Simplification of CPCS is based on a Look-Up-Table (LUT) for determining the CEA groups' position. However, simplification brings approximations that result in a loss of operational margin, which necessitates compensation. Appropriate compensation is performed based on the result of analysis. FPGAs (Field Programmable Gate Arrays) are presented as a way to compensate for the inadequacies of current systems by providing faster execution speeds and a lower Common Cause Failure rate (CCF).

A Study on the Speed Change on the Arterial Road according to Traffic Volume and Speed Limit (교통량과 제한속도에 따른 간선도로 속도 변화에 관한 연구)

  • Shin, Eon-kyo;Kim, Ju-hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.5
    • /
    • pp.149-161
    • /
    • 2022
  • Because the speed limit affects moving speed, it is closely related to traffic accidents as well as traffic flow. The existing speed limit calculation methods consider various engineering factors such as lanes, intersection spacing, driveways, crosswalks, 85 percentile speed, land uses, and roadway geometric characteristics etc. However, it can be said that the engineering analysis is insufficient because the traffic impact analysis considering traffic volume is not carried out. In addition, only 85 percentile speed, which is the spot speed, does not reflect the characteristics of the traffic flow on the road. In this paper, the effect of the speed limit change on the moving speed and the travel speed was analyzed in detail accordinr to the variation of intersection spacing and traffic volume. And by using the results, we proposed a speed limit calculation method that maintains the same service level as before the speed limit change, thereby increasing the speed improvement effect and reducing the difference between moving speed and travel speed. In addition, a variable speed limit operation method according to the change in traffic volume was also suggested. This method is expected to be effective in terms of safety by reducing the speed difference, which affects the severity of traffic accidents, while securing the speed improvement effect, and increasing the speed limit compliance rate of drivers by operating the speed limit that reflects the speed change due to the variation of traffic volume.

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

Evaluation of Limit Loads for Circumferentially Cracked Pipes Under Combined Loadings (원주방향 표면 결함이 존재하는 배관에 가해지는 비틀림을 포함한 복합하중에 대한 한계하중식 제시)

  • Ryu, Ho-Wan;Han, Jae-Jun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.453-460
    • /
    • 2015
  • Since the Fukushima nuclear accident, several researchers are extensively studying the effect of torsion on the piping systems In nuclear power plants. Piping installations in power plants with a circumferential crack can be operated under combined loading conditions such as bending and torsion. ASME Code provides flaw evaluations for fully plastic fractures using limit load criteria for the structural integrity of the cracked pipes. According to the recent version of Code, combined loadings are provided only for the membrane and bending. Even though actual operating conditions have torsion loading, the methodology for evaluating torsion load is not established. This paper provides the results of limit load analyses by using finite element models for circumferentially cracked pipes under pure bending, pure torsion, and combined bending and torsion with tension. Theoretical limit load solutions based on net-section fully plastic criteria are suggested and verified with the results of finite element analyses.

Impacts on Water Surface Level of the Geum River with the Diversion Tunnel Operation for Low Flow Augmentation of the Boryong Dam (금강-보령댐 도수터널 운영에 따른 금강 본류 내 수위 영향 분석 연구)

  • Jang, Suk-Hwan;Oh, Kyoung-Doo;Oh, Ji-Hwan
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1031-1043
    • /
    • 2017
  • Recently severe drought caused the water shortage around the western parts of Chungcheongnamdo province, South Korea. A Diversion tunnel from the Geum river to the Boryong dam, which is the water supply dam for these areas has been proposed to solve this problem. This study examined hydraulic impacts on the Geum river associated with the diversion plan assuming the severe drought condition of 2015 would persist for the simulation period of 2016. The hydraulic simulation model was verified using hydrologic and hydraulic data including hourly discharges of the Geum river and its 8 tributaries, fluctuation of tidal level at the mouth of the river, withdrawals and return flows and operation records of the Geum river barrage since Feb. 1, 2015 through May 31, 2015. For the upstream boundary condition of the Geum river predicted inflow series using the nonlinear regression equation for 2015 discharge data was used. In order to estimate the effects of uncertainty in inflow prediction to the results total four inflow series consisting of upper limit flow, expected flow, lower limit flow and instream flow were used to examine hydraulic impacts of the diversion plan. The simulation showed that in cases of upper limit and expected flows there would be no problem in taking water from the Geum river mouth with a minimum water surface level of EL(+) 1.44 m. Meanwhile, the simulation also showed that in cases of lower limit flow and instream flow there would be some problems not only in taking water for water supply from the mouth of the Geum river but also operating the diversion facility itself with minimum water surface levels of EL(+) 0.94, 0.72, 0.43, and 0.14 m for the lower limit flow without/with diversion and the instream flow without/with diversion, respectively.