• Title/Summary/Keyword: Operating limit

Search Result 518, Processing Time 0.026 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Pig Manure and Food Waste(III): Design and Operation Guideline (가축분뇨 병합처리 바이오가스화를 위한 설계 및 운전 기술지침 마련 연구(III) 설계 및 운전 지침(안) 중심으로)

  • Lee, Dongjin;Moon, HeeSung;Son, Jihwan;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.99-111
    • /
    • 2017
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to bio-gasification facilities treating organic wastes. Based on the results obtained during the field surveys, the overall design and operation guidelines for bio-gasification facilities, monitoring items, cycle and commissioning period were presented. According to the flow of anaerobic digestion process, Various design factors for bio-gasification facilities were proposed in this study. When designing the initial anaerobic digestion capacity, 10 ~ 30% of the treatment capacity was applied considering the discharge characteristics by the incoming organic wastes. At the import storage hopper process, limit concentration of transporting organic wastes was limited to TS 10 % or less, and limit concentration of inhibiting factor was suggested in operation of anaerobic digester. In addition, organic loading rate (OLR) was shown as $1.5{\sim}4.0kgVS_{in}/(m^3{\cdot}day)$ for the combined bio-gasification facilities of animal manure and food wastes. Desulfurization and dehumidification methods of biogas from anaerobic digestor and proper periods of liquifization tank were suggested in design guideline. It is recommended that the operating parameters of the biogasification facilities to be maintained at pH (acid fermentation tank 4.5~6.5, methane fermentation tank 6.0~8.0), temperature variation range within $2^{\circ}C$, management of volatile fatty acid and ammonia concentration less than 3,000 mg/L, respectively.

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

An Optimizing Simulation for Designing the Numbers of Electric Train Car (전동열차 편성량수 설계를 위한 최적화 시뮬레이션)

  • Kim, Ick-Hee;Yun, Dong-Hee;Kum, Ki-Jung;Lee, Sang-Myoung
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.3
    • /
    • pp.95-106
    • /
    • 2012
  • The railway service in the Seoul metropolitan area is facing variety of l changes such as extension of service coverage, new construction, and introduction of express service which in turn causes changes on demands. The demand affects train operation characteristics (frequency of service, train formation) as well as on the congestion rate which is one of the major evaluation index in metropolitan area user service. For the efficient operation of the train, the relationship among the minimization of fleet number, operating cost, and service level has been analyzed. Using the Powersim, which is a system dynamics (System Dynamics) simulation program for realizing optimized simulation for train-formation, this paper identified that some stations of Gyeong-bu line exceeded limit congestion rate(150%) of a fleet already that means it is best to maintain current condition of the line; however, the Gyeong-in line and the Gwa-chon line showed no excess of the limit congestion rate so that it is possible to reduce 2-4 fleets of train for efficient operation. In addition, in case of Jang-hang line between Cheon-an and Sin-chang, a train consisting of 10 fleets provides services which is same formation of train for Gyeong-bu line. This study proved that the congestion rate will not rise greatly with only 4 fleets of a train for the service in Jang-hang line, and it is considered that a study for shuttle service between Cheon-an and Sin-chang is necessary.

An Evaluation of Exposure to Petroleum Based Dry Cleaning Solvent Used in Commercial Dry Cleaning Shops (석유계 솔벤트를 사용하는 세탁소 작업자의 노출평가)

  • Jeong, Jee Yeon;Yi, Gwang Yong;Lee, Byung kyu;Lee, Naroo;Kim, Bong Yeon;Kim, Kwang Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • In previous report, we presented that petroleum based solvents used in dry cleaning shop was almost similar to stoddard solvent defined by ACGIH and NIOSH, and the occupational exposure standard of stoddard solvent could be used in total exposure assessment of those solvents. The specific aim of the this study was to evaluate of the solvent exposure used in commercial dry cleaning shops by using occupational exposure standard of stoddard solvent. We conducted first survey of 8 self-employed dry cleaning shops and 5 factory type dry cleaning shops from July to August, and second survey of the same shops from October to November in 2002. The exposure concentration to the solvent during loading and unloading activity of vented dry cleaning machine was 489.2ppm(GM), 270.3ppm(GM), respectively, which was almost excursion limit(500ppm) of ACGIH, and exceed the ceiling limit(312ppm) of NIOSH. The time-weighted average (TWA) worker exposure to the solvent was 21.3ppm(GM) at self-employed shops, 20.7ppm(GM) at factory type shops on first survey, and 31.1ppm(GM), 33.7ppm(GM), respectively on second survey. The TWA exposure concentration of workers with spotting and cleaning machine operating job was 25.4ppm(GM), which was 2.9 times higher than the TWA exposure concentration, 8.8ppm(GM) of press workers. All TWA exposure concentrations was lower than OEL(100ppm) of stoddard solvent. We found that the most heavy exposure process at dry cleaning was loading, unloading process, and the vent of dry cleaning machine was the main emission source for workers exposure to petroleum based solvent.

Extending the Pressure Limit for Turbomolecular Pump up to 133 Pa by using Conductance-Reducer and Measuring the Pressure Differences in Vacuum Chamber (확장한 진공용기 내부의 압력구배 측정)

  • Hong, S.S.;Khan, Wakil;Kang, S.W.;Yun, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • A dynamic flow system has been developed which can be used for vacuum gauge calibration by comparison method - a calibration method in which the reading of the gauge under calibration is compared to another calibrated vacuum gauge called the "secondary standard" - and other vacuum-related experiments. The chamber of the calibration system is pumped by a turbomolecular pump (TMP), backed by a scroll pump. As maximum acceptable pressure at the inlet of a TMP is 0.1 Pa, above which the TMP decelerates, the pumping speed decreases and it becomes more difficult to adjust pressure under such circumstances. In the present work, high pressures of up to 133 Pa have been generated in the chamber of the newly developed dynamic flow control system by installing a well-designed conductance-reducer in the by-pass line and, at the same time, operating the TMP in safe mode. In addition, the gas flow and pressure distribution within the chamber have been investigated for the entire pressure range (0.1 Pa ~ 133 Pa) while generating pressure dynamically. Maximum deviations in pressure (1.6 %) were observed at point C on the chamber, which is close to the gas inlet port on the top of the chamber.

A Study on Fabrication and Performance Evaluation of Wideband 2-Mode HPA for the Satellite Mobile Communications System (이동위성 통신용 광대역 2단 전력제어 HPA의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.517-531
    • /
    • 1999
  • This paper presents the development of the 2-mode variable gain high power amplifier for a transmitter of INMARSAT-M operating at L-band(1626.5-1646.5 MHz). This SSPA(Solid State Power Amplifier) is amplified 42 dBm in high power mode and 36 dBm in low power mode for INMARSAT-M. The allowable error sets +1 dBm of an upper limit and -2 dBm of a lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier, The HP's MGA-64135 and Motorola's MRF-6401 are used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 are used the high power amplifier. The SSPA was fabricated by the circuits of RF, temperature compensation and 2-mode gain control circuit in aluminum housing. The gain control method was proposed by controlling the voltage for the 2-mode. In addition, It has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. The realized SSPA has 42 dB and 36 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.5:1 The minimum value of the 1 dB compression point gets 5 dBm for 2-mode variable gain high power amplifier. A typical two tone intermodulation point has 32.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.the design target.

  • PDF

Rapid Detection of Salmonella spp. in Fresh-Cut Cabbage by Real-Time PCR (Real-Time PCR을 이용한 신선편이 양배추에서 Salmonella spp.의 신속검출)

  • Bang, Mi-Kyung;Park, Seung-Ju;Kim, Yun-Ji;Kim, Ji-Gang;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.10
    • /
    • pp.1522-1527
    • /
    • 2010
  • This study was conducted to find out the minimal time needed for detection of Salmonella spp. which exist at very low concentration in foods by using real-time PCR. The sal-F and sal-R sequences were used as primers and sal-P was used as a probe. The detection limit of Salmonella spp. was $3.77{\times}10^2\;cfu/mL$ in buffered peptone water (BPW). Microbial growth was monitored after artificially inoculated Salmonella spp. into BPW. The obtained growth curve was well fitted with the equation, y=$0.0127x^2$+0.5927x-0.4317 ($R^2$=0.99), if assuming that 1 cell exists in 25 g sample (0.04 cfu/mL). The microbial concentration will be reduced to 10 fold by adding BPW during sample treatment, so actual initial concentration at the starting point of enrichment is 0.004 cfu/mL. At this condition, real-time PCR detection would be possible only when microbial concentration increase occurs to exceed the detection limit (377 cfu/mL). The time needed for microbial increase was calculated from the growth curve equation as 7 hours and 20 minutes. Therefore the total time required for detection was less than 10 hours including the PCR operating time.

Analysis and Evaluation of CPC / COLSS Related Test Result During YGN 3 Initial Startup (영광 3호기 초기 시운전 동안 CPC / COLSS 관련시험 결과 분석 및 평가)

  • Chi, S.G.;Yu, S.S.;In, W.K.;Auh, G.S.;Doo, J.Y.;Kim, D.K.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.877-887
    • /
    • 1995
  • YGN 3 is the first nuclear power plant to use the Core Protection Calculator (CPC) as the core protection system and the Core Operating Limit Supervisory System (COLSS) as the core monitor-ing system in Korea. The CPC is designed to provide on-line calculations of Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) and to initiate reactor trip if the core conditions exceed the DNBR or LPD design limit. The COLSS is designed to assist the operator in implementing the Limiting Conditions for Operation (LCOs) in Technical Specifications for DNBR/Linear Heat Rate (LHR) margin, azimuthal tilt, and axial shape index and to provide alarm when the LCOs are reached. During YGN 3 initial startup testing, extensive CPC/COLSS related tests ore peformed to ver-ify the CPC/COLSS performance and to obtain optimum CPC/COLSS calibration constants at var, -ious core conditions. Most of test results met their specific acceptance criteria. In the case of missing the acceptance criteria, the test results ore analyzed, evaluated, and justified. Through the analysis and evaluation of each of the CPC/COLSS related test results, it can be concluded that the CPC/COLSS are successfully Implemented as designed at YGN 3.

  • PDF

Recent Reform of Chinese University and Yanbian University (최근 중국의 대학교 개혁과 연변대학교의 개혁)

  • Shizhu, Jin;Xuefeng, Nan
    • Journal of the Korean association of regional geographers
    • /
    • v.11 no.5
    • /
    • pp.488-499
    • /
    • 2005
  • The trends of Chinese and Yanbian University's reform were studied in this work. Although the history of Chinese modem university education is short, and all Chinese Universities experienced same social problems, however, development of each university was different. Especially after 90's, with applying socialism market economy theory, Chinese university education have changed a lot. Main conclusions were summarized as follows. First, to exert university's self-determination, University management system was changed. More and more rights and freedoms of operating university were given to universities which were originally controlled by central and local government. With that, universities were cheered to develop extensively based on its ability. Second, efforts to fit market economy were observed. It reflects in all aspects, such as systems of university financing, operating, admission and graduation of students. Third, professor competition system was adopted to promote professors enthusiasm. Forth, to survival in hot competition among universities, differentiation policy was applied. In brief, it could be said that rapid developments of Chinese university education have achieved recently. However, problems such as universities are still under supervision of central and local government: expand of university scale rather than education quality was focused on: limit of investment to university: lack of legal protection for finical supporting: lack of university democratization were still remain. It was expected that these problems will be solved in future university reforms.

  • PDF

Development of Optimal Train Operation System in Bottle-neck Section According to the Opening of High Speed Railway in Seoul Metropolitan Area (수도권 고속철도개통에 따른 고속선 병목구간 최적열차운행 체계 연구)

  • Chun, Chunggeun;Chung, Sungbong;NamKung, Baekkyu
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.631-637
    • /
    • 2012
  • New Opening of Suseo-Pyeongteak High Speed Railway (HSR) will be a new leap in the Korean railway history. However if this section of HSR line around Seoul Metropolitan Area opens, the confluence of new HSR and existing HSR line in Pyeongteak-Osong section will cause a bottle neck problem. In other words, the opening of Suseo-Pyeongteak HSR line will make the capacity of track reach the limit and the section of railroad between Pyeongteak and Osong will be saturated. This will also make such troubles as restricting the number of train which stops at Cheonan-Asan station. In this study, based on the train assignment theory of TVM430 signal system, the methods of calculating headway and number of train are reviewed and the plan for application of optimal operation pattern during peak hour between Pyeongteak-Osong section is also suggested. To remove the bottle neck problem in this HSR section, 3 alternatives are suggested and the expected effects and problems of each alternative are also analyzed. The results show that the troubles caused by excess of track capacity can be removed without any additional cost if the minimum headway in operating system for HSR is adopted in this section. In the future, if these alternatives are considered to the long-term plan for operating train and signal systems, this will improve the efficiency of train operation, which can remove the bottle neck in the HSR line.