Health Risk Factors of Nurses in the Operating Room (수술실간호사의 건강위험요인)

  • Noh, Won Ja
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In order to investigate and compare the health risk factors of nurses in the operating room(OR nurse) and ward (WARD nurse), the questionnaire survey for subjective symptoms was carried out on 553 nurses(132 OR nurses and 421 WARD nurses) who were employed at seven hospital. The self-administered questionnaries were composed of low back pain, subjective fatigue symptoms, musculo-skeletal symptoms, psychological stress and reproductive function. The results were as follows : 1. In the type of working posture and working environment, there were significant difference between two groups for working posture, waist form, height of working table, satisfaction of chair, lifting & carring. 2. Job satisfaction, duration of work, height of working table, satisfaction of chair, lifting & carring were significantly associated the low back pain. 3. In the complaints of subjective fatigue symptoms, the total mean score was higher in OR nurse than WARD nurse, but there was not significant. The items that the mean score of OR nurse was significantly higher than WARD nurse were 'head feels muddled', 'apt to forget', 'feel choky'. 4. In the complaints of musculo-skeletal syrrptoms, the total mean score was higher in OR nurse than WARD nurse, but there was not significant. The item that the mean score of OR nurse was significantly higher WARD nurse was 'wrist discomfort or pain'. 5. The comparison of spontatenous abortion in married nurses who had the experience of pregnancy were significantly associated the stress risk group. 6. In all of OR and Ward nurses, the job satisfaction is associated with subjective fatigue symptoms, musculo-skeletal symptoms, and stress. In conclusion, it suggested that working posture, working environment, stress, and job satisfaction were health risk factors of nurses working in the operating room. Further prospective intervention studies should be conducted to educate right working posture, improve of working environment, decrease of stress, and increase of job satisfaction.

  • PDF

Design and Implementation of Interface Middleware for Improved Portability on General Operating System (범용 운영체제의 이식성 향상을 위한 인터페이스 미들웨어 설계 및 구현)

  • Kim, Yeon-Il;Lee, Sang-Gil;Lee, Seung-Il;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.4
    • /
    • pp.17-28
    • /
    • 2015
  • The applications program that running on Operating System has high dependence. Because environment of OS and standard libraries that supports are different. For those reason, Applications that perform the same function should be implemented in accordance with the new operating system. This results in a temporal and economic waste not only in subsequent maintenance of application but also in management. Even though, to solve this problem Cygwin or MinGW has been distributed, they do not support the portability of the application but provide a virtual environment and the tool. Therefore, in this paper, we design the wrapper format interface middleware using the POSIX and standard C library to support the application performing the same function on virtual environment and without code modification. The middleware can be selectively loading the API that is classified by basic and extend. This allows to managing the application size efficiently. Also, perform the comparative experiments and performance evaluation for application, on equipped with the Interface Middleware Linux, Unix, Windows and on Cygwin.

Simulations of a System Dynamics Model for Operations and Maintenance of Activated-Sludge Wastewater Treatment Plants (활성슬러지 하수처리시설 운영 및 유지관리를 위한 시스템다이내믹스 모델의 모의에 관한 연구)

  • Park, Suwan;Kim, Bong Jae;Jun, Hwan Don;Kim, In Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.905-912
    • /
    • 2006
  • In this paper, simulation methods of the system dynamics model developed by Das et al. (1997) for activated-sludge wastewater treatment plants are illustrated in an attempt to determine the operating rules and the policies related to capacity expansion of an activated-sludge wastewater treatment plant. For existing conditions, the analyses were performed by varying activated-sludge return rate to observe changes in effluent water quality and treatment efficiency. The effluent water quality is also analyzed for various average daily inflow conditions and activated-sludge return rates. As a result, without expanding the aeration tank, maximum average daily inflow that can satisfy the effluent water quality standard of BOD $0.02kg/m^3$ was determined as $2,840m^3/hr$, subject to 100% of activated-sludge return rate while other factors remain constant. When the activated-sludge return rate is less than 100%, expansion of the aeration tank is necessary and minimum sizes of the aeration tank to satisfy the effluent water quality standard were determined for various activated-sludge return rates. In addition, the total operating and maintenance as well as unit treatment cost regression equations for activated-sludge wastewater treatment plants are suggested by using the cost data that are obtained from Water and Wastewater Division, Ministry of Environment. The regression analyses showed that the economies of scale phenomena exist in the operating and maintenance costs of activated-sludge wastewater treatment plants.

A study of improvement on the air filtering system of the subway (지하철 공기정화시스템 개선에 관한 연구)

  • Kim, Yong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1089-1096
    • /
    • 2008
  • The subway in Seoul, Korea has been constructed and operating 8 lines and 265 subway stations since 1974. And now it' been operated in the metropolis like Busan, Daegu, Gwangju, Incheon. The subway system is being given a great deal of weight on the public transportation system. It means that the citizens of seoul are getting exposured to the underground environment more and more. As the quality of life is getting better, the desire for a pleasant(healthy) environment has been increased. so we have to study effective environment management plans for the subway, When considering Indoor air pollution as another serious environment problem.

  • PDF

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Evaluation of Operating Parameters of Reject Water Treatment System with Pilot-scale Biofilm Nitritation Plant at Field Condition (반류수처리를 위한 현장 pilot plant 생물막 아질산화 반응조에서 운전인자 평가)

  • Han, Jinhee;Kwon, Min;Han, Jonghun;Yun, Zuwhan;Nam, Haiuk;Ko, Joohyung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.636-641
    • /
    • 2007
  • A pilot-scale biofilm nitiritation reactor was operated with the reject water from a large wastewater treatment plant. The effects of various operating parameters including pH, temperature, dissolved oxygen, solids and organic concentrations were examined. A stable nitritation was achieved at operating pH range of 7.3 to 8.8 with an alkalinity addition. Higher operating temperature of $35{\pm}0.7^{\circ}C$ achieved more stable nitritation compared to $30{\pm}0.2^{\circ}C$. It has been noticed that nitrite accumulation maintained with DO, solids and organic concentrations range of 0.8 to 3.9 mg/L, 3,400 to 11,000 mg/L, and 86 to 572 mg/L, respectively. It seems that the accumulation of nitrite was caused by both the inhibition of $NO_2{^-}$ oxidizers due to free ammonia and the maintenance of the high operating temperature of $35^{\circ}C$ which promote to accumulate the $NH_4{^+}$ oxidizers in the reactor. According to microbial community analysis of fluorescence in situ hybridization and INT-Dehydrogenase measurements, more nitrifiers were presented in attached form compared to suspended growth.

An Efficient Memory Allocation Scheme for Space Constrained Sensor Operating Systems (공간 제약적인 센서 운영체제를 위한 효율적인 메모리 할당 기법)

  • Yi Sang-Ho;Min Hong;Heo Jun-Youg;Cho Yoo-Kun;Hong Ji-Man
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.626-633
    • /
    • 2006
  • The wireless sensor networks are sensing, computing and communication infrastructures that allow us to monitor, instrument, observe, and respond to phenomena in the harsh environment. Sensor operating systems that run on tiny sensor nodes are the key to the performance of the distributed computing environment for the wireless sensor networks. Therefore, sensor operating systems should be able to operate efficiently in terms of energy consumption and resource management. In this paper, we present an efficient memory allocation scheme to improve the time and space efficiency of memory management for the sensor operating systems. Our experimental results show that the proposed scheme performs efficiently in both time and space compared with existing memory allocation mechanisms.

A Study on the Revision of Regulations for Effective Operation of Anchorage (정박지의 효율적 운영을 위한 세칙 개정방안)

  • Yun, Gwi-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.398-404
    • /
    • 2014
  • The criteria of operating anchorage and the unit of anchorage capacity have not been unified and the different terms have been used in same matters in each regulations related to the anchorages provided in major domestic ports. The competent authorities and vessels which are going to use anchorages are confused due to those situations. This paper suggests the schemes to unify criteria of operating anchorage, the unit of anchorage capacity and terms used in same matters through reviewing the anchorage operating regulations provided in major domestic ports. In addition, this paper suggests that the principles of anchorage naming, the unit of anchorage capacity and the number of vessels that can be accommodated should be established at the next revision of regulations through reviewing the status of anchorages in major foreign ports to minimize the confusion on operating anchorages.