• Title/Summary/Keyword: Operating duty

Search Result 251, Processing Time 0.03 seconds

LOW PRESSURE LOOP EGR SYSTEM ANALYSIS USING SIMULATION AND EXPERIMENTAL INVESTIGATION IN HEAVY-DUTY DIESEL ENGINE

  • Lee, S.J.;Lee, K.S.;Song, S.H.;Chun, K.M.
    • International Journal of Automotive Technology
    • /
    • v.7 no.6
    • /
    • pp.659-666
    • /
    • 2006
  • EGR(Exhaust Gas Recirculation) systems are extensively used to reduce NOx emissions in light duty diesel engine but its application to heavy duty diesel engines is yet to be widely implemented. In this study, the simulation model for a EURO 3 engine was developed using WAVE and then its performance and emission levels were verified with experimental results. The possibility of operating a EURO 3 engine with LPL EGR system to satisfy the EURO 4 regulation was investigated. Each component of the engine was modeled using CATIA and WaveMesher. The engine test mode was ESC 13, and the injection timing and fuel quantity were changed to compensate for the reduction of engine power caused by applying EGR. As a result of the simulation, it was found that EURO 4 NOx regulation could be satisfied by applying an LPL EGR system to the current EURO 3 engine.

Thermal Analysis According to Duty Ratio of IPM Type BLDC Motor (IPM type BLDC 전동기의 통전비에 따른 온도 특성 해석)

  • Kim, Yong-Tae;Cho, Gyu-Won;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.42-47
    • /
    • 2014
  • The use of BLDC motor in Vehicle and industrial field, it is operated by continuous and intermittent driving. When the intermittent driving is occurred by the rise and fall of temperature repeatedly, it was represented by different characteristics in case of continuous driving. So, it is very important that heat source estimation according to the duty ratio. In this paper, temperature characteristics according to the operating method of BLDCM was calculated by using the thermal equivalent circuit, and the validity of the study was demonstrated as compared to the calculated and experimental results.

Time Synchronization for WSN Nodes Operating on Low-Energy Sleep-Wake Cycles (저 에너지의 취침 기상 사이클로 작동하는 무선센서 네크워크 노드들을 위한 시간 동기화)

  • Yun, Ho-Jung;Yun, Joo-Sung;Lee, Sung-Gu
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.3
    • /
    • pp.331-335
    • /
    • 2010
  • Previous low-energy time synchronization methods have mainly focused on reducing the number of transmission or reception packets. However, this paper proposes a method that reduces the percentage of time a node has to be awake (the duty cycle), assuming that a periodic sleep-wake cycle is used to conserve energy. Based on our experience with actual WSN devices, a system model is proposed, and the potential performance of the proposed method, with different parameter values, is analyzed. To further demonstrate the feasibility of our method, experiments were conducted using nine WSN devices in a $3{\times}3$ grid network topology. The results show the average synchronization error is 107.57 $\mu{s}$ in duty cycle 5% and synchronization period 10 sec, and 130 $\mu{s}$ in duty cycle 2.5% and synchronization period 20 sec.

Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle (상용차 하이브리드 냉방시스템 냉방 성능 특성 연구)

  • Lee, Ho-Seong;Jeon, Hanbyeol;Kim, Jung-Il;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.419-425
    • /
    • 2019
  • The objective of this study was to investigate the cooling performance characteristics of a hybrid refrigeration system in a heavy duty vehicle. The tested hybrid refrigeration system had additionally an electric compressor besides the present mechanical compressor for selective use according to the operating conditions. The applied electric compressor was a scroll type and with 18.0 cc displacement. In order to analyze the performance characteristics of the hybrid refrigeration system with respect to the cooling capacity and Coefficient of Performance (COP), other components, including two different types of compressors, were installed and tested under various operating conditions such as compressor speed and air flow rate of the evaporator. When the electric compressor was operated at 4,500 rev/min, the cooling capacity was about 4.0kW and COP was 3.5. When the mechanical compressor was operated, whereas the cooling capacity was higher than the electric controlled compressor, COP was lower due to the larger displacement and higher power consumption. To analyze the hybrid system operating characteristics due to reasonable cooling capacity with electric compressor operation, the mechanical compressor and electric compressor were operated by turns every 10 minutes under certain system operating conditions. Because surge pressure occurred when both compressors were switched on, the operating strategy required some time to balance the system pressure.

Performance of Fuel Cell System for Medium Duty Truck by Cooling System Configuration (상용차용 고분자 전해질 연료전지 냉각시스템 배열에 따른 성능 특성)

  • WOO, JONGBIN;KIM, YOUNGHYEON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.236-244
    • /
    • 2021
  • Fuel cell systems for medium duty truck require high power demands under driving. Since high power demands results in significant heat generation, thermal management is crucial for the performance and durability of medium duty truck. Therefore, various configurations of dual stacks with cooling systems are investigated to understand appropriate thermal management conditions. The simulation model consists of a dynamic fuel cell stack model, a cooling system model equipped with a controller, and the mounted controller applies a feedback controller to control the operating temperature. Also, In order to minimize parasitic power, the comparison of the cooling systems involved in the arrangement was divided into three case. As a result, this study compares the reaction of fuel cells to the placement of the cooling system under a variety of load conditions to find the best placement method.

Design of digital clock level translator with 50% duty ratio from small sinusoidal input (작은 정현파입력의 50% Duty Ratio 디지털 클럭레벨 변환기 설계)

  • Park, Mun-Yang;Lee, Jong-Ryul;Kim, Ook;Song, Won-Chul;Kim, Kyung-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.8
    • /
    • pp.2064-2071
    • /
    • 1998
  • A new digital clock level translator has been designed in order to produce a clock source of the internal logic circuits. The translator output has 50% duty ratio from small sinusoidal input such as TCXO which oscillates itself in poratable components. The circuit consists of positive and negative comparators, RS latch, charge pump, and reference vol- tage generator. It detects pulse width of the output waveform and feedbacks the control signal to the input com-parator. It detects pulse width of the output waveform and feedbacks the control signal to the input com-parator reference, producing output waveform with valid 50% duty ratio of the digital signal level. The designed level translator can be used as a sampling clock source of ADC, PLL and the colck source of the clock synthesizer. The circuit wasdesigned in a 0.8.mu.m analog CMOS technology with double metal, double poly, and BSIM3 circuit simulation model. From our experimental results, a stable operating characteristics of 50 +3% duty ratio was obtained from the sinusoidal input wave of 370 mV.

  • PDF

Effect of Plasma Electrolytic Oxidation Conditions on Oxide Coatings Properties of Die-Cast AZ91D Mg Alloy (플라즈마 전해 산화 처리조건에 따른 다이캐스트 AZ91D Mg 합금 위에 제조된 산화피막 특성)

  • Park, Seong-Jun;Lim, Dae-Young;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.29 no.10
    • /
    • pp.609-616
    • /
    • 2019
  • Oxide coatings are formed on die-cast AZ91D Mg alloy through an environmentally friendly plasma electrolytic oxidation(PEO) process using an electrolytic solution of $NaAlO_2$, KOH, and KF. The effects of PEO condition with different duty cycles (10 %, 20 %, and 40 %) and frequencies(500 Hz, 1,000 Hz, and 2,000 Hz) on the crystal phase, composition, microstructure, and micro-hardness properties of the oxide coatings are investigated. The oxide coatings on die-cast AZ91D Mg alloy mainly consist of MgO and $MgAl_2O_4$ phases. The proportion of each crystalline phase depends on various electrical parameters, such as duty cycle and frequency. The surfaces of oxide coatings exhibit as craters of pancake-shaped oxide melting and solidification particles. The pore size and surface roughness of the oxide coating increase considerably with increase in the number of duty cycles, while the densification and thickness of oxide coatings increase progressively. Differences in the growth mechanism may be attributed to differences in oxide growth during PEO treatment that occur because the applied operating voltage is insufficient to reach breakdown voltage at higher frequencies. PEO treatment also results in the oxide coating having strong adhesion properties on the Mg alloy. The micro-hardness at the cross-section of oxide coatings is much higher not only compared to that on the surface but also compared to that of the conventional anodizing oxide coatings. The oxide coatings are found to improve the micro-hardness with the increase in the number of duty cycles, which suggests that various electrical parameters, such as duty cycle and frequency, are among the key factors controlling the structural and physical properties of the oxide coating.

The design of C-GIS and the analysis of its Performance test results (C-GIS의 설계 및 성능평가 결과분석)

  • Shin, Y.J.;Kim, M.H.;Ryu, H.K.;Lee, Y.H.;Kim, C.H.;Kim, J.K.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF

Design of Non-Dissipative Snubber for Current-Fed Half-bridge Converter Operating at Duty Ratio above 0.5 (0.5보다 큰 시비율로 동작하는 전류원 하프-브릿지 컨버터의 무손실 스너버 설계)

  • 강정일;한상규;윤현기;김정은;윤명중;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.405-412
    • /
    • 2002
  • Since the switching device of current-fed bridge-type topology suffers from him-off voltage spikes associated with larger energy than that of voltage-fed topology, a high-efficiency non-dissipative snubber is considered essential. However, the complicated operation and the capricious performance according to various conditions make the design of the non-dissipative difficult. In this paper, the non-dissipative snubber employed in the current-fed half-bridge converter operating at a duty ratio above 0.5 is completely analyzed and the design considerations are discussed. Some design examples and the experimental results are provided to confirm the analysis and design presented in this paper.

Evaluations for Representativeness of Light-Duty Diesel Vehicles' Fuel-based Emission Factors on Vehicle Operating Conditions (연료 소비량에 기반한 소형 경유차 대기오염물질 배출계수의 운전조건별 대표성 평가)

  • Lee, Taewoo;Kwon, Sangil;Son, Jihwan;Kim, Jiyoung;Jeon, Sangzin;Kim, Jeongsoo;Choi, Kwangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.745-756
    • /
    • 2013
  • The purpose of this study is to evaluate representativeness of fuel-based emission factors. Twelve light-duty diesel vehicles which meet Euro-3 to 5 legislative emission limits were selected for emission tests. Second-by-second modal emission rates of vehicles were measured on a standard laboratory chassis dynamometer system. An off-cycle driving cycle was developed as a representative Korean real-world on-road driving cycle. Fuel-based emission factors were developed for short trip segments that involved in the selected driving cycle. Each segment was defined to have unit travel distance, which is 1 km, and characterized by its average speed and Relative Positive Acceleration (RPA). Fuel-based $NO_x$ emission factors demonstrate relatively good representativeness in terms of vehicle operation conditions. $NO_x$ emission factors are estimated to be within ${\pm}20%$ of area-wide emission factor under more than 40% of total driving situations. This result implies that the fuel-based $NO_x$ emission factor could be practically implemented into the on-road emission management strategies, such as a remote sensing device (RSD). High emitting vehicles as well as high emitting operating conditions heavily affect on the mean values and distributions of CO and THC emission factors. Few high emitting conditions are pulling up the mean value and biasing the distributions, which weaken representativeness of fuel-based CO and THC emission factors.