• Title/Summary/Keyword: Operating State

Search Result 1,750, Processing Time 0.027 seconds

Effect of control route on the unstart/restart characteristics of an over-under TBCC inlet

  • Li, Nan;Chang, Juntao;Tang, Jingfeng;Yu, Daren;Bao, Wen;Song, Yanping
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.4
    • /
    • pp.431-444
    • /
    • 2018
  • Numerical simulations have been conducted to study the unstart/restart characteristics of an over-under turbine-based combined-cycle propulsion system (TBCC) inlet during the inlet transition phase. A dual-solution area exists according to the Kantrowitz theory, in which the inlet states may be different even with the same input parameters. The entire transition process was divided into five stages and the unstart/restart hysteresis loop for each stage was also obtained. These loops construct a hysteresis surface which separates the operating space of the engine into three parts: in which a) inlet can maintain a started state; b) inlet keeps an unstarted state; c) inlet state depends on its initial state. During the transition, the operation of the engine follows a certain order with different backpressures and splitter angles, namely control route, which may result in disparate inlet states. Nine control routes with different backpressures and transition stages were designed to illuminate the route-dependent behavior of the inlet. The control routes operating towards the unstart boundary can make the inlet transit from a started state into an unstarted one. But operating backward the same route cannot make the inlet restart, additional effort should be made.

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part I : Analytical Study

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.17-26
    • /
    • 2003
  • In this paper, the comparative steady-state operating performance analysis algorithms of the stand-alone single-phase self-excited induction generator (SEIG) is presented on the basis of the two nodal admittance approaches using the per-unit frequency in addition to a new state variable de-fined by the per-unit slip frequency. The main significant features of the proposed operating circuit analysis with the per-unit slip frequency as a state variable are that the fast effective solution could be achieved with the simple mathematical computation effort. The operating performance results in the simulation of the single-phase SEIG evaluated by using the per-unit slip frequency state variable are compared with those obtained by using the per-unit frequency state variable. The comparative operating performance results provide the close agreements between two steady-state analysis performance algorithms based on the electro-mechanical equivalent circuit of the single-phase SEIG. In addition to these, the single-phase static VAR compensator; SVC composed of the thyristor controlled reactor; TCR in parallel with the fixed excitation capacitor; FC and the thyristor switched capacitor; TSC is ap-plied to regulate the generated terminal voltage of the single-phase SEIG loaded by a variable inductive passive load. The fixed gain PI controller is employed to adjust the equivalent variable excitation capacitor capacitance of the single-phase SVC.

Preventive and Emergency Control of Power System for Transient Stability Enhancement

  • Siddiqui, Shahbaz A.;Verma, Kusum;Niazi, K.R.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • This paper presents preventive and emergency control measures for on line transient stability (security) enhancement. For insecure operating state, generation rescheduling based on a real power generation shift factor (RPGSF) is proposed as a preventive control measure to bring the system back to secure operating state. For emergency operating state, two emergency control strategies namely generator shedding and load shedding have been developed. The proposed emergency control strategies are based on voltage magnitudes and rotor trajectories data available through Phasor Measurement Units (PMUs) installed in the systems. The effectiveness of the proposed approach has been investigated on IEEE-39 bus test system under different contingency and fault conditions and application results are presented.

Development of partial state feedback control algorithm for nonlinear overhead crane whose two axes are moved simultaneously (두 축이 동시에 운동하는 비선형 천장 크레인의 부분상태 궤환제어 알고리즘 개발)

  • 이종규;이상룡
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.395-398
    • /
    • 1996
  • In this study, when the nonlinear overhead crane which allows simultaneously travel and traverse motion moves a desired transport route, the object suspended the end of rope does undesirable swing motion. Nonlinear overhead crane pertubes in the vicinity of an operating point, therefore the nonlinear overhead crane is modified to linear overhead crane for the operating point. The linear overhead crane was controlled to swing angles of the object by the ratio of torque inputs to motors of the girder and the trolley. As a basis for the result of the linear overhead crane, the nonlinear overhead crane was controlled swing angles of the object and positions of the overhead crane without collision with environmental equipment by partial state feedback control.

  • PDF

Study on Space Configuration and Area Holding State of Variation Type at the Latest Built Middle Schools in Gwangju (최근에 설립된 광주지역 중학교의 교과교실제 공간 분석)

  • Kim, Jeong-Gyu;Kim, Jeong-So
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.5
    • /
    • pp.3-10
    • /
    • 2013
  • This study was carried out to obtain basic data for architectural plans on the facilities relocation needed in operating the departmentalized classroom system at the latest built middle schools. For this, floor plans of ten middle schools built in Gwangju after 2009 were analyzed about space configuration and area holding state. The process of this study is as follows: (1) To investigate proper area holding state for operating variation type, this study analyzed area of departmentalized classrooms, homebases and teachers' offices. (2) To investigate space configuration for operating variation type, this study analyzed composition of departmentalized classrooms, learning-support facilities and homebases. (3) On the base of those analyses, this study proposed some directions for architectural plans on the facilities relocation.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

Hybrid UPS with Energy Storage System Function (ESS 기능을 갖는 하이브리드 UPS)

  • Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.266-275
    • /
    • 2014
  • This paper proposes the hybrid UPS(Uninterruptible Power Supply) with ESS(Energy Storage System) function. The proposed hybrid UPS is operating in four states, which are normal state, battery state, ESS state, and bypass state. In case of peak load time or power shortage, the system is operating in ESS state in which the stored energy of the battery is used to manage the power effectively. The validity of proposed system are verified by simulations and experiments.

Design of the Kernel Hardening Function in the Linux Network Module (리눅스 네트워크 모듈에서 커널 하드닝 기능 설계)

  • 장승주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.961-969
    • /
    • 2004
  • A panic state is often caused by careless computer control. It could be also caused by a kernel programmer's mistake. It can make a big problem in computer system when it happens a lot. When a panic occurs, the process of the panic state has to be checked, then if it can be restored, operating system restores it, but if not, operating system runs the panic function to stop the system in the kernel hardening O.S. To decide recovery of the process, the type of the panic for the present process should be checked. 1'he value type and the address type have to restore the process. If the system process is in a panic state, the system should be designed to shutdown hardening function In the Linux operating system. So it has to decide whether the process should be restored or not before going to the panic state.

Receding Horizon Control of a Parallel Hybrid Electric Vehicle (병렬형 하이브리드 차량의 동적 구간 제어)

  • Jean, Soon-Il;Kim, Ki-Back;Jo, Sung-Tae;Park, Yeong-Il;Lee, Jang-Moo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.659-664
    • /
    • 2000
  • Fuel-consumption and catalyst-out emissions of a parallel hybrid electric vehicle are affected by operating region of an engine. In many researches, It is generally known that it is profitable in fuel- consumption to operate engine in OOL(Optimal Operating Line). We established the mathematical model of a parallel hybrid electric vehicle, which is linear time-invariant. To operate an engine in OOL, we applied RHC(Receding Horizon Control) to the driving control of a parallel hybrid electric vehicle. And it is known that the RHC has advantages such as good tracking performance under state and control constraints. This RHC is obtained by using linear matrix inequality (LMI) optimization. In this paper, there are three main topics. First, without state and control constraints, the optimal tracking of OOL was simulated. Second, with state and control constraints by engine and motor performances, the optimal tracking of OOL was simulated. In the last, we studied on the optimal gear ratio. That is to say, we combined the RHC and the iterative simulation to extract the optimal gear ratio. In this simulation, the vehicle is commanded to track the reference vehicle trajectory and the engine is operated in the optimal operating region which is made by the state constraints.

  • PDF

Design and Implementation of Data Logger for Elevator Remote Monitoring (승강기 원격 관제를 위한 데이터 수집기 설계 및 구현)

  • Gu, Bongen
    • Journal of Platform Technology
    • /
    • v.8 no.4
    • /
    • pp.3-10
    • /
    • 2020
  • An elevator maintenance company maintains many types of elevators from many manufactures. So, they want to use manufacture- or type-independent elevator remote monitoring system. To do this, data logger, that receives elevator operating state data from sensor module installed in elevator and transfers the data to database, is required. In this paper, we design and implement data logger of elevator remote monitoring system for providing elevator operation state information to elevator maintenance company. Data logger receives elevator operation state data from sensor module installed in elevator, decodes data, and converts to API data for transferring elevator operation state data to server. In this paper, we describe the implementation of data logger using python, and show that our implementation of data logger is successfully operating in a real elevator operating environment via log message displayed at screen.

  • PDF