Effects of Key Operating Parameters on the Efficiency of Two Types of PEM Fuel Cell Systems (High-Pressure and Low-Pressure Operating) for Automotive Applications

  • Kim Han-Sang;Lee Dong-Hun;Min Kyoungdoug;Kim Minsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1018-1026
    • /
    • 2005
  • The proton exchange membrane (PEM) fuel cell system consisting of stack and balance of plant (BOP) was modeled in a MATLAB/Simulink environment. High-pressure operating (compressor type) and low-pressure operating (air blower type) fuel cell systems were con­sidered. The effects of two main operating parameters (humidity and the pressure of the supplied gas) on the power distribution characteristics of BOP and the net system efficiency of the two systems mentioned above were compared and discussed. The simulation determines an optimum condition regarding parameters such as the cathode air pressure and the relative humidity for maximum net system efficiency for the operating fuel cell systems. This study contributes to get a basic insight into the fuel cell stack and BOP component sizing. Further research using muli­object variable optimization packages and the approach developed by this study can effectively contribute to an operating strategy for the practical use of fuel cell systems for vehicles.

A Study of the Effect of Compressor Performance Map on the Efficiency of High-pressure Operating PEMFC Systems in Automotive Applications (압축기 성능 맵이 자동차용 가압형 고분자전해질형 연료전지 시스템 효율에 미치는 영향 연구)

  • Cho, Donghoon;Kim, Han-Sang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.604-611
    • /
    • 2012
  • For the commercialization of fuel cell powered vehicle, it is highly important to improve the performance and efficiency of an automotive polymer electrolyte membrane fuel cell (PEMFC) system. The performance and efficiency of PEMFC systems are significantly influenced by their operating conditions. Among these conditions, the system operating pressure is considered as the one of the main factors. In this study, to investigate the effects of operating pressure on the performance and efficiency of automotive PEMFC systems, two types of high-pressure operating PEMFC systems adopting two different compressors (i. e. different performance maps) are modeled by using MATLAB/Simulink environment. The PEMFC system efficiency and parasitic compressor power are mainly analyzed and compared for the two types of high-pressure operating PEMFC systems under the same system net power conditions. It is expected that this kind of study can contribute to provide basic insight into the operating strategies of high-pressure operating PEMFC systems for automotive use.

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

The Effects of Injector Nozzle Geometry and Operating Pressure Conditions on the Transient Fuel Spray Behavior

  • Koo, Ja-Ye
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.617-625
    • /
    • 2003
  • Effects of Injector nozzle geometry and operating pressure conditions such as opening pressure, ambient pressure. and injection pressure on the transient fuel spray behavior have been examined by experiments. In order to clarify the effect of internal flow inside nozzle on the external spray, flow details Inside model nozzle and real nozzle were alto investigated both experimentally and numerically. for the effect of injection pressures, droplet sizes and velocities were obtained at maximum line pressure of 21 MPa and 105 MPa. Droplet sizes produced from the round inlet nozzle were larger than those from the sharp inlet nozzle and the spray angle of the round inlet nozzle was narrower than that from the sharp inlet nozzle. With the increase of opening pressure, spray tip penetration and spray angle were increased at both lower ambient pressure and higher ambient pressure. The velocity and size profiles maintained similarity despite of the substantial change in injection pressure, however, the increased injection pressure produced a higher percentage of droplet that are likely to breakup.

A Study on the Analysis of the Performance and Efficiency of a Low-pressure Operating PEMFC System for Vehicle Applications Using MATLAB/Simulink (MATLAB/Simulink를 이용한 자동차용 상압형 PEM 연료전지 시스템의 성능 및 효율 분석 연구)

  • Park, Raehyeok;Kim, Han-Sang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.5
    • /
    • pp.393-400
    • /
    • 2013
  • The air supply system has a significant effect on the efficiency of polymer electrolyte membrane fuel cell (PEMFC) systems. The performance and efficiency of automotive PEMFC systems are greatly influenced by their air supply system configurations. This study deals with the system simulation of automotive PEMFC systems using MATLAB/Simulink framework. In this study, a low-pressure operating PEMFC system adopting blower sub-module (turbo-blower) is modeled to investigate the effects of stack operating temperature and air stoichiometry on the parasitic power and efficiency of automotive PEMFC systems. In addition, the PEMFC net system efficiency and parasitic power of air supply system are mainly compared for the two types (low-pressure operating and high-pressure operating) of automotive PEMFC systems under the same net power conditions. It is suggested that the obtained results from this system approach can be applied for establishing the novel operating strategies for FC vehicles.

A Study on Pressure Surge Accompanied by Repeated Valve Operation in Oil Hydraulic Pipeline (유압관로에서 절환밸브 반복조작에 따른 충격압력 발생 현상에 관한 연구)

  • Jung, Yong-Gil;Yum, Man-U;Lee, Jin-Geol;Lee, Il-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.2
    • /
    • pp.33-42
    • /
    • 1988
  • In a large scale oil hydraulic system having repeatedly operated actuator, such as a large scale forging press, pressure surges often due to the recombination of oil column in a return line attached to the downstream side of a directional control valve. Expecially, the pressure surges appear very severe ones at a certain valve operating frequency. These pressure surges restrict the operating frequency of the hydraulic system. But related reports on the above mentioned phenomenon are rarely to be found. In this study, therefore, the authors investigate the exact reason why such severe pressure surges occur at a certain range of valve operating frequency. The study is performed by experiment and numerical computation on the relationship between pressure surges and valve operating frequency.

  • PDF

Multiple Orifice Technique for Pressure Drop in Compressible Pipe Flows

  • Kim, Heuy-Dong;Koo, Byoung-Soo;Woo, Sun-Hoon;Setoguchi, Toshiaki
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.459-464
    • /
    • 2000
  • In order to investigate the effectiveness of an orifice system in producing pressure drops and the effect of compressibility on the Pressure drop, computations using the mass-averaged implicit Wavier-Stokes equations were applied to the axisymmetric pipe flows with the operating pressure ratio from 1.5 to 20.0. The standard k-e turbulence model was employed to close the governing equations. Numerical calculations were carried out for some combinations of the multiple orifice configurations. The present CFD data showed that the orifice systems, which have been applied to incompressible flow regime to date, can not be used for the hint operating Pressure ratio flows. The orifice interval did not strongly affect the total pressure drop but the orifice area ratio more than 2.5 led to high pressure drops. The total pressure drop rapidly increased in the range of the operating pressure ratio from 1.5 to 4.0, but it did not depend on the operating pressure ratio over 4.0.

  • PDF

The effect of the charging pressure and operating frequency in the Stirling Cryocooler (충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발)

  • 박성제;홍용주;김효봉;고득용;김양훈;유병건;이기백
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.62-68
    • /
    • 2001
  • This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

  • PDF

Large Eddy Simulation on the Drag and Static Pressure Acting on the Blade Surface of Three-Dimensional Small-Size Axial Fan with Different Operating Loads (운전부하에 따른 3차원 소형축류홴 날개표면에 작용하는 정압과 항력에 대한 대규모와 모사)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 2017
  • The large-eddy simulation(LES) was carried out to evaluate the drag and static pressure acting on the blade surface of a small-size axial fan(SSAF) under the condition of unsteady-state, incompressible fluid and three-dimensional coordination. The axial component of drag coefficient increases with the increase of operating load, but the radial components have negligible sizes regardless of operating loads. Otherwise, the static pressures acting on the blade surfaces of SSAF show different distributions around the operating point of D equivalent to the stall. Also, with the increase of operating load, the static pressures acting on the pressure and suction surfaces of blade concentrate at the tips and leading-edges as a whole.

A Computational Study of a Variable Sonic Ejector Flow (가변형 음속 이젝터 유동에 관한 수치해석적 연구)

  • Lee, Jun-Hee;Choi, Bo-Gyu;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.526-531
    • /
    • 2003
  • A cone cylinder is used to obtain variable operation conditions of a sonic ejector-diffuser system. The cone cylinder is movable to change the ejector area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream. The numerical simulations are based on a fully implicit finite volume scheme of the compressible, Reynolds-Averaged, Navier-Stokes equations. The ejector throat area is varied between 3.94 and 8.05, and the operating pressure ratio is changed from 3.0 to 9.0. The results show that the entrainment ratio and mass flux ratio become more dependent on the ejector throat area ratio, when the pressure operating ratio is low. The total pressure losses produced in the present ejector system increase with the operating pressure ratio and the ejector area ratio, but for a given operating pressure ratio, the losses are not significantly dependent on the ejector area ratio when it is larger than about 5.0.

  • PDF