• Title/Summary/Keyword: Opening location

Search Result 263, Processing Time 0.027 seconds

Analysis of Opening Characteristics for Puffer GCB (파퍼식 가스차단기의 동작특성 해석)

  • Kim, Hong-Gyu;Jeong, Jin-Gyo;Park, Gyeong-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.560-567
    • /
    • 2002
  • This paper presents the calculation of opening characteristics for puffer GCB with the equations of the flow field and the motion of the driving mechanism. To obtain the stroke curve, the motion equation is solved simultaneously with the Euler equations. For a given Piston location, the flow field is solved. The pressure inside the Puffer chamber is then used to calculate the moving velocity and the new position of the piston. The FVFLIC method is employed to solve the axisymmetric Euler equations and the motion equation is solved by the Runge-Kutta method. The method is applied to the puffer GCB model and the stroke curve and the pressure rise in puffer chamber under no load condition are compared with the measured ones.

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

A Study on the Ventilation Conditions for the Prevention of Spontaneous Combustion of Small Ship Engine Room (소형선박 기관실의 자연발화 방지를 위한 환기조건에 관한 연구)

  • Park, Chan-Su
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.11-19
    • /
    • 2008
  • In order to show the most suitable ventilation conditions for the prevention of spontaneous combustion of small ship engine room, We have performed CFD simulation and analyzed flow and temperature fields. The flow patterns indicated differently according to the number and location of supply and exhaust opening. The case of locating the exhaust openings at the center of left and right side ceiling to the longitudinal symmetric line were more effective to eliminate the generated heat. When the number of supply and exhaust openings were increased, the case of increasing the number of exhaust opening showed more suitable ventilation conditions. The most suitable ventilation conditions in order to prevent the spontaneous combustion of small ship engine room was predicted that the supply opening located at the center of front and after side ceiling to across symmetric line, and the exhaust opening located at the center of both side walls.

A Method on Estimation of Avoiding Open Range on Shell-type Roller Gate (쉘타입 로울러 게이트의 회피개도량 산정 방법)

  • Chung, Jee-Seung;Jung, Hae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.85-91
    • /
    • 2017
  • When the shell-type roller gate is partly open, at a certain height the large vibration is caused due to resonance and the vibration can cause damage to the gate. In this study, the review on amplitude of vibration and the possible resonance occurring at the time of opening or closing of gate is performed. Throughout the natural frequency analysis, the installation location of the measuring instrument was selected. On opening or closing of gate, the measurement of gate vibration is performed. The natural frequencies according to the opening range of the gate is analyzed. As a result of measurement and analysis, we proposed ranges in which vibration occurs largely and resonance is predicted as an avoiding open ranges, or the safe opening or closing of the shell-type roller gate. The application of this paper's avoiding open range estimation method of shell-type roller gate can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites

  • Abdel-Kareem, Ahmed H.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.281-300
    • /
    • 2014
  • This study presents the experimental results of twenty three reinforced concrete beams with rectangular web openings externally strengthened with Fiber Reinforced Polymers (FRP) composites bonded around openings. All tested beams had the same geometry and reinforcement details. At openings locations, the stirrups intercepted the openings were cut during fabrication of reinforcement cage to simulate the condition of inclusion of an opening in an existing beam. Several design parameters are considered including the opening dimensions and location in the shear zone, the wrapping configurations, and the amount and the type of the FRP composites in the vicinity of the openings. The wrapping configurations of FRP included: sheets, strips, U-shape strips, and U-shape strips with bundles of FRP strands placed at the top and sides of the beam forming a fan under the strips to achieve closed wrapping. The effect of these parameters on the failure modes, the ultimate load, and the beam stiffness were investigated. The shear contribution of FRP on the shear capacity of tested beams with web openings was estimated according to ACI Committee 440-08, Canadian Standards S6-06, and Khalifa et al. model and examined against the test results. A modification factor to account for the dimensions of opening chords was applied to the predicted gain in the shear capacity according to ACI 440-08 and CSA S6-06 for bonded Glass Fiber Reinforced Polymers (GFRP) around openings. The analytical results after incorporating the modification factor into the codes guidelines showed good agreement with the test results.

The inertial coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 2014
  • For a building with a dominant windward wall opening, the wind-induced internal pressure response can be described by a second-order non-linear differential equation. However, there are two ill-defined parameters in the governing equation: the inertial coefficient $C_I$ and the loss coefficient $C_L$. Lack of knowledge of these two parameters restricts the practical use of the governing equation. This study was primarily focused on finding an accurate reference value for $C_I$, and the paper presents a systematic investigation of the factors influencing the inertial coefficient for a wind-tunnel model building including: opening configuration and location, wind speed and direction, approaching flow turbulence, the model material, and the installation method. A numerical model was used to simulate the volume deformation under internal pressure, and to predict the bulk modulus of an experimental model. In considering the structural flexibility, an alternative approach was proposed to ensure accurate internal volume distortions, so that similarity of internal pressure responses between model-scale and full-scale building was maintained. The research showed 0.8 to be a reasonable standard value for the inertial coefficient.

A Lagrangean Relaxation Method for the Zero-One Facility Location Problem with Uniform Customer Demands and Facility Capacities

  • Tcha, Dong-Wan;Yoo, Chun-Beon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.12 no.2
    • /
    • pp.21-31
    • /
    • 1986
  • Consider a capacitated facility location problem in which the demands of customers are all equal and so are the capacities of facilities. Under the restriction that each customer's uniform demand be met by exactly one facility, the objective is to select a set of facilities to open, and to assign customer's demand to them so as to minimize the total cost which includes fixed costs of opening facilities as well as variable assignment costs. The problem is modelled as a pure zero-one program which may be viewed as a variant of well-known capacitated facility location problems. The purpose of this study is to develop efficient computational procedures for solving the pure zero-one facility location problems. Due to the special structure of our zero-one location problem with uniform demand, it can be converted to a location problem with the unimodular property. A Lagrangean relaxation algorithm is developed to solve the location problem. The algorithm is made efficient by employing a device which exploits the special structure of a surrogate constraint. The efficiency of the algorithm is analyzed through computational experiments with some test problems.

  • PDF

A Study on the Location Selection of North Korean Economic Development Zone Using AHP (AHP를 활용한 북한 경제개발구의 산업 입지선정 분석에 관한 연구)

  • Park, Chul-Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.4
    • /
    • pp.87-100
    • /
    • 2020
  • Economic Development Zone(EDZ) in the province is one of the foreign policy for economic development of North Korea. North Korea has promulgated 27 Economic Development Zones(5 EDZs as central level and 22 EDZs as provincial level) to promote economic growth through the expansion of external opening policy. EDZs of the provinces play an important role in North Korea's national and regional economic growth. The purpose of this study is to select analytical criteria that can be quantified when considering the location conditions of North Korean economic development zones when domestic companies advance into North Korea according to the progress of inter-Korean economic cooperation, and derive the relative importance between the criteria. After that, based on this, we intend to quantify the evaluation of the location priority of the economic development zone. In this study, through AHP analysis results, when domestic companies enter North Korea, we derive the importance and preference of location selection factors when considering the location conditions of North Korean economic development zones. Taking into account the reality of North Korea when the Korean company entered the North economic development zone following location for evaluation. That is, logistics and transportation, industrial infrastructure, competitiveness, and management incentives. And 14 sub-factors were selected and AHP analysis was performed.

Optimization of the Unducted Auxiliary Ventilation for Large-Opening Underground Limestone Mines (대단면 지하 석회석 광산내 무풍관 국부통기 최적화 연구)

  • Nguyen, Van Duc;Lee, Chang Woo
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.480-507
    • /
    • 2019
  • This paper aims at optimizing the auxiliary ventilation system in large-opening limestone mines with unducted fans. An extensive CFD and also site study were carried out for optimization at the blind entries. The fan location, operating mode, and layout are the parameters for optimization. Since the jet stream discharged from the auxiliary fan is flowing faster than 15 m/s in most of the cases, the stream collides with floor, sides or roof and even with the jet stream generated from the other fan placed upstream. Then, it is likely to lose a large portion of its inertial force and then its ventilation efficiency drops considerably. Therefore, the optimal fan installation interval is defined in this study as an interval that maximizes the uninterrupted flowing distance of the jet stream, while the cross-sectional installation location can be optimized to minimize the energy loss due to possible collision with the entry sides. Consequently, the optimization of the fan location will improve ventilation efficiency and subsequently the energy cost. A number of different three-dimensional computational domains representing a full-scale underground space were developed for the CFD study. The velocity profiles and the CO concentrations were studied to design and optimize the auxiliary ventilation system without duct and at the same time mine site experiments were carried out for comparison purposes. The ultimate goal is to optimize the auxiliary ventilation system without tubing to provide a reliable, low-cost and efficient solution to maintain the clean and safe work environment in local large-opening underground limestone mines.

An Analytical Model of Co-oscillating Tide under Frictional Effect in the Yellow Sea

  • Kang, Sok-Kuh;Chung, Jong-Yul;Kang, Yong-Q.;Lee, Sang-Ryong
    • Journal of the korean society of oceanography
    • /
    • v.34 no.1
    • /
    • pp.22-35
    • /
    • 1999
  • The response of the tidal waves to friction effect is investigated in terms of deformation of Kelvin and Poincare modes, The 1st Poincare mode does not exist over the low frequency region less than the critical frequency of omega ${\omega}$${\sqrt{2f}}$, with ${\gamma}$/f=0.0, but the mode comes to exist in the presence of friction. When friction exists and its magnitude increases, the wave number increases, indicating that the wave length of the Poincare mode becomes increasingly short with increasing friction. The damping coefficient gradually increases with increasing friction over the high frequency region, but the trend is reversed over the low frequency region. In case of Kelvin wave the present study substantiates the characters of Kelvin wave examined by Mofjeld (1980) and Lee (1988). Based on the examination of frictional effects on the tidal wave propagation, the co-oscillating tides in the Yellow Sea are examined by considering both the head opening and bottom friction effects. As friction is introduced and increased in addition to partial opening at bay head, the location of the amphidromic point near the Shantung Peninsula moves more southwestward. This southwestward movement of the amphidromic point is increasingly compatible with the observed location of Ogura's or Nishida's tidal chart of the M$_2$ tide.

  • PDF