• 제목/요약/키워드: Opening force

검색결과 285건 처리시간 0.031초

공동주택 지하주차장의 풍력환기 성능에 관한 연구 - 환기구 면적 및 주변건물의 영향 - (A Study on Ventilation Performance driven by Wind Force in Underground Parking Lots of Apartment - Influence of Opening Size and Surrounding Building -)

  • 노지웅
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.29-34
    • /
    • 2012
  • As a series of studies about natural ventilation driven by wind in basement parking lots of apartment, the influence of opening size and surrounding buildings on ventilation rate was analyzed. Natural ventilation in underground parking lots almost rely on wind than temperature difference. To investigate natural ventilation driven by wind, wind tunnel tests by using scale model and tracer gas method were conducted. $CO_2$-gas concentration was measured, natural ventilation rates were calculated. The experimental results showed that the natural ventilation rate is more reliable to wind direction and surrounding building than opening size and distance between buildings. It was verified that surrounding buildings play a principal role in increasing air flow rate by accelerating wind speed, and growing turbulence intensity. And it showed that ventilation performance is able to be increased by oblique wind to entrance ramp than head on wind in underground parking lots with surrounding buildings.

Effect of Slot Opening on the Cogging Torque of Fractional-Slot Concentrated Winding Permanent Magnet Brushless DC Motor

  • Yan, Jianhu;Zhang, Qiongfang;Feng, Yi
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.78-82
    • /
    • 2016
  • Cogging torque will affect the performance of a permanent magnet Brushless DC Motor (BLDCM), thus the reduction of cogging torque is key for BLDCM optimization. In this paper, the phase shifting of cogging torque for a fractional-slot concentrated winding BLDCM is analyzed using the Maxwell tensor method. Moreover, a 9-slot 10-pole concentrated winding BLDCM driven by ideal square waveform is studied with the finite element method (FEM). An effective method to reduce the cogging torque is obtained by adjusting the slot opening. In addition, the influences of different slot openings on back electromotive force (back-EMF), air gap flux density and flux linkage are investigated and experimentally validated using the prototype BLDCM.

20대 일부 성인의 교합력 관련 요인 (Influencing factors on bite force of adults in twenties)

  • 이미라;정수진
    • 한국치위생학회지
    • /
    • 제14권3호
    • /
    • pp.303-310
    • /
    • 2014
  • Objectives : The purpose of the study is to investigate the effects of bite force by gender and physical features. Methods : A self-reported questionnaire was filled out by 212 college students in Chungnam province from October to December, 2013. The questionnaire consisted of oral health condition. The bite force of the first molar teeth was measured. Results : Males showed the greater bite force than females(p<0.001). Those who had temporomandibular joint(TMJ) disorder suffered from mouth opening difficulty and weaker bite force than those who had not(p<0.05). Those who had malocclusion showed weaker bite force (p<0.01). Those who had a habit of chewing gums tended to have greater bite force than those who had not(p<0.05). The bite force was correlated with height(r=0.309), weight(r=0.345), and BMI(r=0.249)(p<0.01). Conclusions : Males showed greater bite force than females. The temporomandibular joint (TMJ) disorder, subjective malocclusion, and eating habit also affected the bite force.

작동각을 고려한 차량 후드 프레임의 실험식 개발 (Development of Experimental Equation of Hood Frame for Vehicle Considering Operating Angle)

  • 송요선;허관도;손인수
    • 동력기계공학회지
    • /
    • 제20권3호
    • /
    • pp.57-63
    • /
    • 2016
  • This paper presents the experimental result and theoretical analysis result to investigate the correlation between the operating force, angle and locking torque for vehicle hood frame. Also, we derived the experimental equation that using the results for experiment and theory. The hood frame is switching-devices used for opening and closing the vehicle hood. It needs the correlation data between locking torques of each joint, operating force and angle of hood frame. The correlation data for torque and reaction force of hood frame obtained through experiment and theory analysis. Finally, the experimental equation of the locking torque prediction for the hood frame is derived.

충격 흡수기의 동적거동 해석 프로그램을 이용한 각 파라미터가 댐핑력에 미치는 영향 조사 (An Investigation into the Effect of Each Parameter of S/A on the Damping Force Using Dynamic Behaviour Analysis P/G)

  • 박재우;신상윤;주동우;이시복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.371-376
    • /
    • 1996
  • The damping force of shock absorber in an automobile is determined by the components which construct the S/A. In this study we investigate the individual effect of these components on damping force. In addition, opening of important valve doling compression and tension cycle due to up-down reciprocation movement is also researched. Thus we are to strictly control the properties and tolerance of components having important effects on tile damping force and to produce S/A of better quality.

  • PDF

Simplified equations for Vierendeel design calculations of composite beams with web openings

  • Panedpojaman, Pattamad
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.401-416
    • /
    • 2018
  • Composite beams with web openings are vulnerable to Vierendeel bending failure. The available methods provide quite conservative estimates of Vierendeel bending resistance. An alternative design method to compute the resistance was proposed in this study, based on quadratic nonlinear interactions of normalized shear force, axial force and Vierendeel bending moment. The interactions of the top and bottom Tee section must satisfy mutual conditions to prevent the Vierendeel failure. The normalized shear force and Vierendeel bending moment of the composite part were used instead in the top Tee interaction. The top Tee axial force was computed based on force equilibrium. Based on a rigid-plastic model, the composite resistance is estimated using an effective slab width of the vertical shear resistance. On using the proposed method, nonlinear reductions due to shear loads and axial forces are not required, in contrast to prior methods. The proposed method was validated against experiments from literature. The method limitations and accuracy as well as the Vierendeel behavior were investigated by finite element simulations, with varied composite beam parameters. The proposed design loads are less conservative than earlier estimates and deviate less from the simulations.

Substituents Effect on Aziridine Chemistry: N-Inversion Energy, Reactivity and Regioselectivity of Nucleophilic Ring-opening

  • Park, Gyoo-Soon;Kim, Seok-Chan;Kang, Han-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권9호
    • /
    • pp.1339-1343
    • /
    • 2005
  • The N-inversion energies and nucleophilic ring-opening reactions of N-substituted aziridine compounds are investigated using B3LYP/6-31+$G^*$ methods, where substituents (R) on the nitrogen atom has been H (1), Me (2), Ph (3), Bn (4), CHMePh (5), $CO_2Me$ (6), COPh (7) and $SO_2Ph$ (8). The N-inversion energy with X group are decreased as the following order: R = CHMePh (17.06 kcal/mol) $\gt$ Me (16.97) $\gt$ Bn (16.70) $\gt$ H (16.64) $\gt$ $SO_2Ph$ (12.18) $\gt$ Ph (8.91) $\gt$ COPh (5.75) $\gt$ $CO_2Me$ (5.48). For reactivity of the ring opening toward cyanide ion, the aziridine 6 (R=$CO_2Me$) is shown to be the most reactive one. During the ring opening of aziridine 6 by CN$^{\ominus}$, the torsional OCNC angle becomes near to $180^{\circ}$, where the geometry allows for the effective incorporation of electrons of the nitrogen atom to the C=O bond. It would be a possible driving force for nucleophilic ring opening reaction as well as decreasing the N-inversion energy barrier. Regarding to the regioselectivity, the orientation of nucleophile in ring opening reaction appears to be different in the case of 9 and 10. The results are discussed in terms of steric/electronic effect of the $C_2$-substituents.

축소 철근콘크리트 벽체의 내력과 균열진전에 대한 개구부모서리 균열제어 띠의 영향 (Effect of Crack Control Strips at Opening Corners on the Strength and Crack Propagation of Downsized Reinforced Concrete Walls)

  • 왕혜린;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.40-47
    • /
    • 2022
  • 이 연구의 목적은 철근콘크리트 벽체의 내력, 변형 및 균열진전에 대한 개구부 모서리의 사인장 균열 제어를 위한 다양한 보강방법들이 효율성을 평가하는 것이다. 개구부 모서리의 사인장 균열제어 보강방법으로서 이 연구에서 제안한 균열제어 띠, 기존의 경사보강근 배근방법, 그리고 응력분산곡면판을 선택하였다. 균열제어 띠에서는 균열치유 기능성이 부여된 것도 함께 고려하였다. 개구부 주위의 체적변화 및 균열 폭 진전을 평가하기 위하여 개구부 모서리에서 사인장 균열 유도를 위한 축소 벽체 실험을 수행하였다. 실험결과 균열제어 띠는 경사보강근 및 응력분산곡면판에 비해 개구부 주위의 체적변화 감소 및 개구부 모서리 균열 폭 제어에 효율적이었다. 균열 치유 기능이 포함된 균열제어 띠는 사전 실험에서 발생한 균열들을 치유하면서 축소 벽체의 내력 향상 및 균열 폭 감소에 가장 좋은 성능을 보였다.

Analysis of behaviour of steel beams with web openings at elevated temperatures

  • Yin, Y.Z.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.15-31
    • /
    • 2006
  • Beams with web openings are an attractive system for multi-storey buildings where it is always desirable to have long spans. The openings in the web of steel beams enable building services to be integrated within the constructional depth of a floor, thus reducing the total floor depth. At the same time, the increased beam depth can give high bending moment capacity, thus allowing long spans. However, almost all of the research studies on web openings have been concentrated on beam behaviour at ambient temperature. In this paper, a preliminary numerical analysis using ABAQUS is conducted to develop a general understanding of the effect of the presence of web opening on the behaviour of steel beams at elevated temperatures. It is concluded that the presence of web openings will have substantial influence on the failure temperatures of axially unrestrained beams and the opening size at the critical position in the beam is the most important factor. For axially restrained beams, the effect of web openings on the beam's large deflection behaviour and catenary force is smaller and it is the maximum opening size that will affect the beam's response at very high temperatures. However, it is possible that catenary action develops in beams with web openings at temperatures much lower than the failure temperatures of the same beam without axial restraint that are often used as the basis of current design.

인장과 굽힘을 받는 배관의 원주방향 관통균열 개구면적 평가 (Crack Opening Area Assessment of Circumferential Though Wall Crack in a Pipe Subjected to Tension and Bending)

  • 김상철;김만원
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.61-66
    • /
    • 2008
  • It is important to calculate the exact crack opening area in the cracked pipe subjected to axial force and bending moment. Among many solutions for obtaining the crack opening displacement, Paris-Tada's expression, which is derived from energy method, is open used in fracture analysis for piping crack problems because of its simplicity. But Paris-Tada's equation has conservativeness when radius over thickness ratio(R/t) is ten or less, for it is based on the stress intensity factor solution having a compliance function derived from a simple shell theory. In this paper we derived a new expression using a different stress intensity factor solution which is able to consider the variation of compliance through wall thickness in a cracked pipe. Conservativeness of both equations was examined and compared to finite element analysis results. Conservativeness of the new equation is decreased when R/t > 10 and increased slightly when R/t < 10 compared with Paris-Tada's. But Both equations were highly conservative when R/t < 10 compared with finite element analysis results.